Notice ID: d6cd84490a2e47668250f249a744d65eAward NoticeAwarded
H365--Base + 4 OPTNs - VA-STC HCS Pharmacy Hood Certs & Wipe Sampling
Awarded on January 29, 2021. Full description on SAM.gov.
Awarded tounder 36C26321P0285 (source: SAM.gov award notice)• $415.9K
Overview
- Posted
- January 29, 2021
- Notice type
- Award Notice
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 541380: Testing Laboratories and Services
- Agency
- Department of Veterans Affairs
Notice details
- Place of performance
- St. Cloud VA Health Care System 4801 Veterans Dr., St. Cloud, 56303
- Last updated
- Sep 9, 2025
- Award date
- Jan 29, 2021
- Award amount (SAM.gov award notice)
- $415.9K
Identifiers
- Solicitation number
- 36C26321Q0212
- Notice ID
- d6cd84490a2e47668250f249a744d65e
- Award number (PIID)
- 36C26321P0285
Description
The Department of Veterans Affairs Network 23 Contracting Office (NCO 23), on behalf of The US Department of Veterans Affairs Health Care System of Saint Cloud, MN, hereinafter referred to as VA-STC located at 4801 Veterans Drive, Saint Cloud, MN 56303-2015, contemplates issuing a Request for Quote (RFQ) in order to award a single, firm fixed-price contract for provision of required testing and services identified in the most current versions of United States Pharmacopeia (USP) Chapter <797> and Chapter <800> in addition to any services required by the St. Cloud VA Health Care System using Controlled Environment Testing Association (CETA) Certified National Board of Testing (CNBT) professionals. The performance period will be from time of contract award through end of the 1-year base period, currently estimated to be 2/1/2021 1/31/2022. There will also be a potential 4 Option Years offered for this contract. The solicitation and any subsequent award will be conducted in accordance with FAR Part 13, and relevant sections of the Federal Acquisition Regulation and Veterans Administration Acquisition Regulation (VAAR). The applicable NAICS Code is: 541380 TESTING LABORATORIES. The small business size standard is $16.5 million. This requirement is a 100% SET-ASIDE competition for SD/VOSB s only. All qualified offerors are invited to provide their proposal. The Contractor shall provide all testing and certification activities required for compliance of all primary and secondary engineering controls (PECs and SECs) used for compounding sterile preparations in accordance with the RFQ Performance Work Statement (PWS). The tentative issue date for any actual solicitation will follow on/about December 22, 2020. The date is not firm and may change due to events out of our control. Offerors are responsible for checking the website, https://beta.sam.gov, regularly to obtain possible amendments. All parties must obtain all notices and amendments to the solicitation through this website. Hard copies will not be mailed. Proposals must be submitted in accordance with the proposal instructions outlined in the solicitation. Proposals will be due not less than 7 days after the issuance of any solicitation. This notice is for informational purposes only and is not a request for offers. The Government is not obligated to issue a solicitation as a result of this notice. All respondents must be registered AT TIME OF OFFER in the System for Award Management (SAM) database at http://www.sam.gov and complete online Representations and Certifications at http://www.sam.gov. All respondents must be certified AT TIME OF OFFER in the Veteran Business (VIP) database at https://www.vip.vetbiz.va.gov to prove/validate SD/VOSB certification. No other information is available until issuance of the solicitation. Questions will not be answered before solicitation is posted. Questions regarding the solicitation must be in writing. Please submit written questions via email to Contracting Officer, Angela Beck: angela.beck@va.gov; no telephonic inquiries will be accepted. Responses to questions pertaining to the solicitation will be provided through December 31, 2020 only.
Award Overview
Award Number
36C26321P0285
Award Amount (SAM.gov award notice)
$415.9K
Award Date
Jan 29, 2021
Awardee
Awardee UEI
LHJEE619Z753
Original Solicitation
Notice ID: d6cd84490a2e47668250f249a744d65e
Posted Date: Jan 29, 2021
Original Response Deadline: Not specified
More From This Vendor
Top 5 most recent
- $189.0KSigned Aug 22, 2025
- $207.0KSigned Aug 18, 2025
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C26321Q0212- Pre-Solicitation
- Solicitation
- Awarded
This opportunity has been awarded.
- Pre-SolicitationDec 18, 2020
H365--Base YR + 4 OPTN YRs - STC VA HCS Pharmacy Hood Certifications & Wipe Sampling/Testing Commence Approx 2/1/2021
- SolicitationDec 22, 2020
H365--Base YR + 4 OPTN YRs - STC VA HCS Pharmacy Hood Certifications & Wipe Sampling/Testing Commence Approx 2/1/2021
- AwardedCurrentJan 29, 2021
H365--Base + 4 OPTNs - VA-STC HCS Pharmacy Hood Certs & Wipe Sampling
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Amendment 0002 to RFQ 36C26326Q0188 Adding Technical questions and answers Adding S02. RFQ 36C26326Q0188 Amended | - | Combined Synopsis | 08/21/2026 |
| - | Awarded | Open | |
| - | Awarded | Open | |
36C26227Q0022 ******* The purpose of this amendment is to: 1. Respond to questions asked regarding this solicitation. 2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. Base: 12/01/2026 09/30/2027 OY 1: 10/01/2027 09/30/2028 OY 2: 10/01/2028 09/30/2029 OY 3: 10/01/2029 09/30/2030 OY 4: 10/01/2030 09/30/2031 3. Change the response due date from 11/09/2026 to 11/12/2026. Questions and Answers: Q. Can you please let me know the total number of outlets to be tested. A. 3,000 Total. Q. # vacuum inlets A. 3,000 Q. # of medical gas system source equipment & location Bulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center) Q. # of medical gas booms/columns A. 38, Please see attachment named BOOM INVENTORY . Q. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications? A. ASSE 6020 and ASSE 6030 certifications are required. Q. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible? A. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location. Q. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory . Q. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No Q. If this is a follow-on requirement, what is the prior contract number? A. Prior Contract No. : 36C26222C0020 Q. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? A. Please refer to statement of work section V. Scope Q. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? A. The bulk oxygen is owned and maintained by the supplier. Q. Are Category 3 systems, such as dental air and vacuum, in scope? A. Yes Q. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year? A. Only Annual. Q. Does each annual CLIN cover a single inspection event per year? A. Yes Q. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? A. Certs. Must be held by the prime and subcontractor. Q. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? A. Yes Q. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? A. Yes. Q. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? A. Yes, a brief moment. Q. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? A. Only deficiencies. Q. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? A. No. This test will only to be performed for installation, repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas. Q. When was the last annual inspection done, and when was the first inspection due under this contract? A. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26. Q. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection. A. No particulate test performed during verification of newly installed or modified medical gas piping systems only. Q. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99. A. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs. Q. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months. A. VA requires this test to be performed annually. Q. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot. A. Yes Q. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs. A. Yes, if any deficiencies are found. Q. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm. A. Only main Hospital and building 31 (cancer center) will be tested annually. Q. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI? A. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include "Over and Above Repair" to clarify that the contractor must notify the POC immediately if any repairs needs to be made. | - | Combined Synopsis | 11/12/2026 |
The purpose of this amendment is to extend the due date to 11-15-2026 at 10:00 AM EST, to update the Wilmington Seed Order Statement of Work, and to answer vendors’ questions. | - | Combined Synopsis | 11/15/2026 |
Additional Details
Solicitation Number
36C26321Q0212
Archive Date
Feb 13, 2021
Office Address
Saint Paul, MN, 55101