Notice ID: dd8227d2480e42b58bad0a9d6a3b4192Combined Synopsis/Solicitation
H359--Electrical Equipment Testing - CI Period of Performance: 07/01/2023 - 06/30/2024 PO: 636C37117
Archived on September 20, 2023. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 10:00 AM UTC−05:00
- Posted
- June 8, 2023
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 541330: Engineering Services
- Agency
- Department of Veterans Affairs
Notice details
- Office
- NETWORK CONTRACT OFFICE 23 (36C263)
- Place of performance
- Central Iowa Health Care System 3600 30th St Des Moines, IA 50310
- Last updated
- Dec 6, 2025
Identifiers
- Solicitation number
- 36C26323Q0650
- Notice ID
- dd8227d2480e42b58bad0a9d6a3b4192
Description
Electrical Equipment Testing Services for VA Central Iowa Health Care System This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This is a solicitation conducted using FAR Part 13 (Simplified Acquisition Procedures). This announcement constitutes the only solicitation, quotes are being requested. Solicitation number 36C26323Q0650 is issued as a request for quotes (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2023-02. This procurement is a total set-aside for Small Businesses. Prospective offerors must be registered and current in the System for Award Management (SAM) database at time of offer to the Government (https://www.sam.gov). Quotes will only be accepted from responsible contractors. The NAICS code for the solicitation is 541330 Engineering Services with a size standard of $25.5 million. A list of the contract line items, quantities, and units of measure are listed within the attached solicitation documentation. The VA anticipates one firm fixed price contract award to provide Electrical Equipment Testing services to VA Central Iowa Health Care System located at 3600 30th St, Des Moines, IA 50310. The period of performance is 07-01-2023 to 06-30-2024. FAR provisions 52.212-1, 52.212-2, and 52.212-3 apply to this procurement and are detailed within the attached solicitation document. FAR clauses 52.212-4 and 52.212-5 apply to this procurement and are included within the attached solicitation document. Additional requirements are listed within the attached solicitation document. The Defense Priorities and Allocations System (DPAS) does not apply to this acquisition. Technical questions on this solicitation are due via e-mail only to Melissa Garrett, Contracting Officer, at melissa.garrett@va.gov no later than 10:00am Central Standard Time (CST), 05-25-2023. Quotes are due to the Contracting Office by 10:00am CST, 06-13-2023. Quotes are required to be emailed to melissa.garrett@va.gov prior to the solicitation closing date and time. It is the responsibility of the offeror to ensure their quote is received in its entirety by the Contracting Officer before the solicitation closing. Contact Melissa Garrett, Contracting Officer, at melissa.garrett@va.gov for information regarding the solicitation.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C26323Q0650- Combined Synopsis
- 3×Combined SynopsisCurrentMay 19, 2023
H359--Electrical Equipment Testing - CI Period of Performance: 07/01/2023 - 06/30/2024 PO: 636C37117
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
36C26227Q0022 ******* The purpose of this amendment is to: 1. Respond to questions asked regarding this solicitation. 2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. Base: 12/01/2026 09/30/2027 OY 1: 10/01/2027 09/30/2028 OY 2: 10/01/2028 09/30/2029 OY 3: 10/01/2029 09/30/2030 OY 4: 10/01/2030 09/30/2031 3. Change the response due date from 11/09/2026 to 11/12/2026. Questions and Answers: Q. Can you please let me know the total number of outlets to be tested. A. 3,000 Total. Q. # vacuum inlets A. 3,000 Q. # of medical gas system source equipment & location Bulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center) Q. # of medical gas booms/columns A. 38, Please see attachment named BOOM INVENTORY . Q. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications? A. ASSE 6020 and ASSE 6030 certifications are required. Q. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible? A. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location. Q. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory . Q. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No Q. If this is a follow-on requirement, what is the prior contract number? A. Prior Contract No. : 36C26222C0020 Q. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? A. Please refer to statement of work section V. Scope Q. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? A. The bulk oxygen is owned and maintained by the supplier. Q. Are Category 3 systems, such as dental air and vacuum, in scope? A. Yes Q. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year? A. Only Annual. Q. Does each annual CLIN cover a single inspection event per year? A. Yes Q. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? A. Certs. Must be held by the prime and subcontractor. Q. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? A. Yes Q. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? A. Yes. Q. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? A. Yes, a brief moment. Q. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? A. Only deficiencies. Q. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? A. No. This test will only to be performed for installation, repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas. Q. When was the last annual inspection done, and when was the first inspection due under this contract? A. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26. Q. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection. A. No particulate test performed during verification of newly installed or modified medical gas piping systems only. Q. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99. A. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs. Q. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months. A. VA requires this test to be performed annually. Q. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot. A. Yes Q. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs. A. Yes, if any deficiencies are found. Q. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm. A. Only main Hospital and building 31 (cancer center) will be tested annually. Q. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI? A. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include "Over and Above Repair" to clarify that the contractor must notify the POC immediately if any repairs needs to be made. | 46% | Combined Synopsis | 11/12/2026 |
NAICS is 541330 - Engineering Services and small business size standard of $25.5. ___________________________________________________________________________________________________ The purpose of this announcement is for market research only. No solicitation will be posted at this time. The Department of Veterans Affairs NCO 15 Contracting Office and John Cochran (JC) VA Medical Center, 915 N Grand Blvd, St. Louis MO. 63106, seeks capabilities information on interested vendors to provide AE Services for design completion for project. The responding interested offerors are requested to provide procurement capabilities from licensed professional architects and engineers currently registered in the state of Missouri or in a state of which Missouri has recognized the engineering license. The specific disciplines which will be evaluated are Architects, Civil Engineer, Mechanical Engineers, Electrical Engineers, Structural Engineers, Industrial Hygienists, Estimators, CAD operators, Project Managers, LEED Consultant, Fire Protection Engineer, and Interior Designer at the medical center. The North American Industry Classification system (NAICS) code for this acquisition is 541330 - Engineering Services and small business size standard of $25.5. PSC: C1DA Magnitude of Construction Project between $500,000 and $1,000,000. Project Intent: A/E Firm shall provide all necessary design and construction period of services for subject project. The VA St. Louis Health Care System, John Cochran Division, will prepare existing space for a new Interventional Radiology equipment in Room A261. This project will renovate the area of the current equipment and reconfigure the area to properly utilize all of the features of the new unit. Work includes demolition of walls, ceilings, flooring and utilities. Existing exam, control and equipment room will be reconfigured to support new equipment needs. New construction includes walls, ceilings, flooring, doors, lead shielding, lights, power, data, phone, systems, new AHU system to support HVAC design guidelines, to allow the vendor to install the new equipment. Project will require assessment of existing lead shielding. Scope to focus on refreshing space instead of a full reconstruction. Responses must be received by 6:00 PM CST on November 05, 2025, via e-mail to the Contracting Officer at Gislaine.Dorvil@va.gov. PLEASE REFERENCE "SOURCES SOUGHT: Project 657-27-207JC Prepare Site for Interventional Radiology Equipment Room A261" IN THE SUBJECT LINE. Respondents will not be contacted regarding their submission or information gathered because of this Sources Sought notice. Interested firms shall be required to respond to additional announcements separately from this announcement without further notice from the Government when posted to the Contract Opportunities website at https://sam.gov/. The Contract Opportunities website is the only official site to obtain these documents. | 46% | Market Research | 11/05/2026 |
Elevator Third-Party Inspection and Testing Services BK & SA | 46% | Combined Synopsis | 10/16/2026 |
Engineering and technical services in support of the Support Equipment Department at the Naval Air Warfare Center Aircraft Division Lakehurst, NJ. | 45% | Solicitation | 12/03/2026 |
45% | Awarded | Open |
Additional Details
Solicitation Number
36C26323Q0650
Archive Date
Sep 20, 2023
Office Address