Description
Sources Sought Notice Sources Sought Notice Page 4 of 4 Sources Sought Notice Sources Sought Notice Page 1 of 4 The Sioux Falls Health Care System requires the purchase of a Fiber Light Source & Photometry Console with the salient characteristics listed below. This is a SOURCES SOUGHT NOTICE only looking for American manufactured equipment as listed below for market research purposes. No proposals are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS OR PRICING AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. The Buy American Act, FAR 52.225-1, applies. Interested vendors shall include the place of manufacture in their responses. Responses to this notice will be treated only as information for the Government to consider as part of their market research efforts. The information provided will be used by the Government in developing its acquisition strategy regarding possible set aside for Veteran Owned and other socio-economic categories of small business. Interested parties are responsible for adequately marking proprietary, restricted or competition sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this notice and parties responding will not be entitled to payment for direct or indirect costs incurred in responding to this notice. The North American Industry Classification System (NAICS) code for this requirement is 334516 Surgical Appliance and Supplies Manufacturing with an SBA Small Business Size Standard of 1,000 employees. The deadline for this information is 4:00 PM Central Time on Thursday, December 19, 2025. (Functional/Performance/Specification (Brand Name or Equal)) This requirement includes meeting Brand Name or equal to the DORIC Fiber Photometry system. The system includes Behavior & Bundle Photometry Console (BBC300), Fiber Photometry with Fluorescence Mini Cubes, Fiber Photometry with Rotary Fluorescence Mini Cube, Bundle-imaging Fiber Photometry, Wireless Photometry, Rotary Bundle-imaging Fiber Photometry, FluoPulse system, Doric Neuroscience Studio V6 software, Danse software, and Fiber Photometry Accessories. Fiber photometry monitors neuronal activity in the brain of freely moving behaving animals that helps correlate brain functioning with animal behavior. It uses implanted fiber-optic cannula to deliver excitation light to a group of neurons labeled with genetically encoded calcium indicators and detect their calcium-related fluorescence fluctuations. While it lacks the cellular/spacial resolution of a miniature fluorescence microscope, fiber photometry uses a relatively simple setup to record fluctuations in the calcium activity of a group of neurons in behaving animals. A smaller cannula's fiber diameter is better suited for deep tissue neuronal activity monitoring than a somewhat larger lens of miniature fluorescence microscopes. Optogenetics uses light to control the activity of specific neurons that have been genetically modified to express light sensitive proteins. Allows researchers to turn neurons on or off based on cell type, enabling causal investigation of neural circuit function. Used to test the role of specific neural pathways in complex behaviors like aggression, anxiety, and sleep. Allows for precise control over when and where neural activity is manipulated. Integrating fiber photometry and optogenetics using specialized software allows for simultaneous recording of neural activity and optogenetic stimulation in freely moving animals. Allows researchers to correlate specific neural activity patterns with specific behaviors. Enables the design of more complex and comprehensive experiments to probe neural circuits. Sioux Falls VA Health Care System requires the following: QTY 1: Behavior & Bundle Photometry Console Must have at least 4 x USB 3.0 ports Must have at least 4 x Camera Trigger ports Must have at least 4 x Analog Outputs (for light source control) Must have at least 8 x Digital Input/Output (DIO) ports Must have at least 24 additional Digital ports (8x inputs/outputs, 8x inputs, 8x outputs) with the extension board QTY 1: 4 laser diodes Fiber Light Source - 4x 638nm - 80 mW, LDFLS-4CH and 4x 450nm - 75 mW, LDFLS-4CH Must meet the following laser diode and fiber light criteria: Optical Fiber: Multimode 50 m Power stability: < 1% over 1 hour with the following Operating Modes: OFF, Continuous, External TTL, External Analog, Computer (USB) TTL Modulation: HI > 2.8 V, LOW < 2.3 V Analog Modulation: 0 - 5 V (80 mA / V and 75mA/ V) Rise / Fall time: < 10 µsec Max modulation frequency: 10 kHz QTY 4: Mono Fiberoptic Patchcord, MFP_200/220/LWMJ-0.22_1m_FC-FCA Must meet the following Fiber-optic capability: 200/220/900-0.37 or Core ( m): 200, Cladding ( m): 220, Buffer: 245, Jacket: 900, NA: 0.37 QTY 1: Branching Box for HD9 pattern - 9 FC inputs, 1 HD9 output Must have at least 9 input ports Must be compatible with FC Input Optical Connector Must be compatible with HD9 Output Optical Connector Must have the following dimension, 211 x 94 x 45 mm QTY 1: Bundle-imaging Fiber Photometry Cube with Targeted Optogenetics Must have a wavelength range of 350 to 1100 nm Must have a field of view (FOV) of Ø3 mm Must have an objective numerical aperture (NA) of 0.40 LEDs Excitation Uniformity must be 80% over FOV Optogenetics Excitation Uniformity must be 65% over FOV Optogenetics Crosstalk between fibers must be >31 dB Must have optical fiber compatibility with the following fiber optic core diameter 200 or 400 µm and NA 0.37 Must be able to measure spectral bandwidth within the following 3 excitation and 2 emission ranges: Excitation #1: 405-410, 410-415, 421-433 or 433-445nm Excitation #2: 460-490 nm Excitation #3: 555-570 nm Emission #1: 500-540 nm Emission #2: 580-600 nm Optical filter attenuation must be > Optical Density (OD) 5 outside band Must be compatible with HD7, HD9 or HD19 Optical fiber connectors. Dimensions must be 220mm x 220mm x 59mm Must have a CMOS (Complementary Metal-Oxide Semiconductor) image sensor Must provide 1024x1024 px resolution Must provide Pixels size down to 5.86 µm x 5.86 µm Must have a frame rate up to 60 Hz Must have a USB 3.0 Computer interface. QTY 1: High Density Fiberoptic Patch cord - Low Autofluorescence QTY 8: Ferrule Connector (FC)/Ferrule Connector (FC) Mating Adapter Round QTY 8: Fiberoptic Rotary Joint, pigtailed with 400 um, NA0.37 fibre, 1.0m input, 0.15m output, optimized for fiber photometry QTY 8: Gimbal holder for FRJ 1x1_PT-G2 - ID 19 mm Must have 96 mm x 69 mm x 25 mm dimensions QTY 8: Mono Fiberoptic Patchcord - Low AutoFluorescence Must have the following Fiber-Optic Codes to ensure system compatibility Optical Fiber Type: Silica/Silica Core: Glass Cladding: Glass Numerical Aperture: 0.22-0.37 Flexibility: Good Auto-Fluorescence: Excellent Core Diameter ( m): 400 Cladding ( m): 440 Buffer ( m): 470 NA: 0.37 Must have the following Jacket Codes to ensure system compatibility. Composition Code: 1100 Description: Hytrel loose tube 1.1 mm Color: Black OD (mm): 1.1 Linear Mass (g/m): 0.5 Must be compatible with the following Connectors: 1st Connector Code: FCM (Flexible metal conduit) 1st Connector Description: FC Connector with Metal Ferrule 2nd Connector Code: MF1.25(F) 2nd Connector Description: Metal Ferrule OD 1.25 mm with Flange QTY 10: Zirconia Sleeve 1.25 mm with black cover Must have a Ferrule Diameter of 1.25mm QTY 30: Mono Fiberoptic Cannula Fiber-Optic must be made from Silica/Silica material Fiber-Optic type must be 400( m) NA 0.37 Fiber Lenth must 5.0mm Receptacle must be a male to female (MF) 1.25 Fiber tip must be flat (FLT) QTY 2: Stereotaxic Cannula Holder 1.25 mm Ferrule diameter must be 1.25mm Rod diameter must be 6.3 mm QTY 1: CamLoop with RGB camera and Wide-Angle lens, Behavior tracking System for closed loop stimulation Must be able to provide 1440 x 1080 px (1.6MP) resolution Must have dynamic range of 12 bits Must provide gain range of 0 to 48 dB Must be able to provide a Frame rate of at least 60 fps at full resolution Sensor format: 1 / 2.9'' Must have a USB 3.0 Interface Minimum exposure of 1 ms or less Lens must be mounted using C-mount or CS-mount QTY 1: Danse 3-year subscription, Data Analysis Software, 1 license QTY 1: Gentec-EO Pronto-SI Power Meter + SM1 Treaded adaptor + 2.5mm receptacle + 1.25mm, receptacle QTY 1: High performance workstation set up for Doric's systems Must have an Intel Core i9 13th gen. 24-core processor or better Must have a minimum RAM of 2x32GB DDR5 5600 Must have GeForce RTX 3060 12GB DDR6 or better graphic card to accurately capture and measure video files. Must have SSD 4TB NVMe + Hard Drive 4TB or better to support the software and system. Must be Win11 Pro compatible to run the system software. QTY 1: Assisted 2x2 Fiber-optic Rotary Joint, 400 um NA0.37 fibre, 1m input, optimized for fiber photometry Part # AFRJ_2x2_PT_400-0.37 QTY 1: Base Station for wireless fiber photometry system Must have a transmission range up to 2 meters Must be able to accommodate 4 headstages Must operate within 2.4 - 2.5 GHz wireless frequency band. Base Station Interface must be compatible with HDMI (to NC500) or USB-B (to BBC300) QTY 1: Wireless Photometry Headstage - ferrule 2.5 mm - 1 integrated photodetector and 2 integrated LEDs. With a 40mAh battery QTY 1: Battery Charger for wireless fiber photometry - Part # WiFP_CHRG Must Interface with a USB-C Power Supply: 1 meter cable USB-C to USB-A Must have a capacity of 4 headstages QTY 10: Multi Fluid Injections Cannulas, OmFC_ZF1.25_400/470-0.37_5.0mm_FLT_4.9mm_PLGS QTY 10: OmFC Fluid Injector Part # FI_OmFC-ZF_140/190_5.1mm QTY 10: Mono Fiberoptic Cannula Part # MFC_400/430-0.37_5mm_ZF2.5_FLT QTY 1: Co-Extruded PE/PVC Tubing for HRJ-OL Part# HRJ-OL _BTCOEX_25Ga_clear (2 meters)
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C26326Q0182.docx
39 KBAdded in Sources Sought version 3Posted
Lifecycle
- 3Version 3Sources SoughtArchivedCurrent
6640--Sioux Falls Health Care System - Brand Name or Equal Supply Procurement of DORIC Fiber Photometry System
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
| - | Awarded | Open | |
This is a combined synopsis/solicitation for commercial supplies prepared in accordance with Part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C26225Q1470 is issued as a request for quote (RFQ) for scope system for endoscopic procedures. This acquisition is set-aside for Small Business concerns. This solicitation incorporates provisions and clauses and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Model Number, Description, Quantity (ea) INS9900, HD Monitor, 16 INS9904, LED Scope, 1.9mm X 2M, 16 INS9902, HD Mini Scope, 1mm X 1M, 16 Salient Characteristics Must provide waterproofing borescope to be used at the sink. Must provide 1mm High Resolution Borescope. Must have a standalone touch monitor with a minimum of 13-inchs and provide 8.4-inch image of lumen being Inspected. Must have holsters to hold each Borescope in place on the monitor. Must be able to connect to the Pure Processing Ergonomic workstations with the Pure Processing Monitor mount. The monitors must be waterproof, as defined by the International Electro Technical Commission is IP65 and Borescopes are IP6. Must record, take pictures, and save to USB drive for documentation. Must have Automatic white balance - always in focus. Must have ergonomic one-plug borescope connector for easier handling. Must have annotation capabilities. Must have brightness adjustment for optimal imaging. The period of performance for this requirement is 90 days ARO. The Contractor shall furnish all supplies at The Greater Los Angeles VA Health Care System located at 11301 Wilshire Blvd, Los Angeles CA, 90073. Shipping included in cost. FOB is destination. NOTE: Potential offers must be aware that the items being acquired are procured as Brand Name or Equal. For those items that are “or equal”. The FAR Clause 52.211-6 Brand Name or Equal applies to this acquisition. Any items quoted as equal not conforming to the requirements of clause 52.211-6 will be considered non-responsive and not considered for award. The North American Industrial Classification System (NAICS) code for this requirement is 334516, Size Standard 1,000 Employees. The Contractor shall adhere to all federal and state laws and regulations in effect during the term of this contract. The Government intends to award a firm fixed price contract. Due to time constraints, responses to the solicitation shall be due on Thursday, September 17, 2026, at 12:00 PM PT Local Time. Offerors are advised that it is your responsibility to review and monitor the website frequently to ensure you have the most up to date information, including amendments. Correspondence or questions may be directed to Jasmine Pressley-Barnard, Contracting Officer at jasmine.pressley-barnard@va.gov with "36C26226Q1470, SCOPE SYSTEM” in the subject line within 48 hours of release of this notice. Telephone inquiries will not be honored. Inquiries after the allotted period may not be responded to due to the time constraints of the procurement. All offerors must be registered in www.sam.gov to do business with the Government. Ensure your registration is correct, current and has not expired. 52.212-2 Evaluation -- Commercial Items (Oct 2014) (a) The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: Lowest priced quotation that meets all the requirements of this solicitation that is both responsive and responsible. Acceptability of equipment shall be established by review of each submitted quotation by the designated evaluator(s). (b) A written notice of award or acceptance of an offer, mailed or otherwise furnished to the successful offeror within the time for acceptance specified with a minimum of at least sixty days, shall result in a binding contract without further action by either party. Before the offer’s specified expiration time, the Government may accept an offer (or part of an offer), whether there are negotiations after its receipt, unless a written notice of withdrawal is received before award. (End of Provision) Must include a completed copy of the provision at 52.212-3 -- Offeror Representations and Certifications -- Commercial Items, with this solicitation or ensure SAM.gov is updated with current information. The clause at 52.212-4, Contract Terms and Conditions -- Commercial Items, applies to this acquisition. The clause at 52.212-5, Contract Terms and Conditions Required To Implement Statutes Or Executive Orders -- Commercial Items, applies to this acquisition. The following clauses also apply: Gray Market Items (a) Gray market items are Original Equipment Manufacturers (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts) for VA Medical Centers. No remanufactures or gray market items will be acceptable. (b) Vendor shall be an OEM, authorized dealer, authorized distributor or authorized reseller for the proposed medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts), verified by an authorization letter or other documents from the OEM, such that the OEM’s warranty and service are provided and maintained by the OEM. All software licensing, warranty and service associated with the medical supplies, medical equipment and/or services contracts for maintenance of medical equipment shall be in accordance with the OEM terms and conditions. (c) The delivery of gray market items to the VA in the fulfillment of an order/award constitutes a breach of contract. Accordingly, the VA reserves the right to enforce any of its contractual remedies. This includes termination of the contract or, solely at the VA’s election, allowing the Vendor to replace, at no cost to the Government, any remanufactured or gray market item(s) delivered to a VA medical Facility upon discovery of such items. (End of clause) In addition, the following clauses shall also apply: 52.202-1 Definitions Jun 2020 52.203-3 Gratuities Apr 1984 52.203-5 Covenant Against Contingent Frees May 2014 52.203-6 Restrictions on Subcontractor Sales to the Government Jun 2020 52.203-8 Cancellation, Rescission and Recovery of Funds for Illegal or Improper Activity May 2014 52.203-10 Price or Fee Adjustment for Illegal or Improper Activity May 2014 52.203-16 Preventing Personal Conflicts of Interest Jun 2020 52.203-17 Contractor Employee Whistleblower Rights Nov 2023 52.203-19 Prohibition on Requiring Certain Internal Confidentiality Agreements or Statements Jan 2017 52.204-13 System for Award Management Maintenance Oct 2018 52.204-19 Incorporation by Reference of Representations and Certifications Dec 2014 52.209-6 Protecting the Government's Interest When Subcontracting with Contractors Debarred, Suspended, Proposed for Debarment, or Voluntarily Excluded Jan 2025 52.209-9 Updates of Publicly Available Information Regarding Responsibility Matters Oct 2018 Deviation Nov 2025 52.209-10 Prohibition on Contracting with Inverted Domestic Corporations Nov 2015 Deviation Nov 2025 52.219-8 Utilization of Small Business Concerns Jan 2025 Deviation Nov 2025 52.222-1 Notice to the Government of Labor Disputes Feb 1997 52.222-35 Equal Opportunity for Veterans Jun 2020 52.222-36 Equal Opportunity for Workers with Disabilities Jun 2020 52.222-37 Employment Reports on Veterans Jun 2020 52.222-40 Notification of Employee Rights Under the National Labor Relations Act Dec 2010 52.222-50 Combating Trafficking in Persons Nov 2021 52.223-23 Sustainable Products May 2024 Deviation Nov 2025 52.226-7 Drug-Free Workplace May 2024 52.226-8 Encouraging Contractor Policies to Ban Text Messaging While Driving May 2024 52.229-4 Federal, State and Local Taxes Feb 2013 Deviation Sep 2025 52.232-17 Interest May 2014 52.232-33 Payment by Electronic Funds Transfer – System for Award Management Jul 2013 52.232-39 Unenforceability of Unauthorized Obligations Jun 2013 52.232-40 Providing Accelerated Payments to Small Business Subcontractors Dec 2013 52.233-1 Disputes May 2014 52.233-3 Protest After Award Aug 1996 52.233-4 Applicable Law for Breach of Contract Claim (OCT 2004) 52.242-13 Bankruptcy Jul 1995 52.242-14 Suspension of Work Apr 1984 52.244-2 Subcontracts Jun 2020 852.203-70 Commercial advertising Jan 2008 852.232-72 Electronic submission of payment requests Nov 2012 852.237-70 Contractor responsibilities Apr 1984 The full text of a clause may be accessed electronically at the following: http://www.acquisition.gov/comp/far/index.html http://www.va.gov/oal/library/vaar/index.asp The following provisions shall also apply: 52.203-11 Certification and Disclosure Regarding Payments to Influence Certain Transactions Sep 2024 52.203-18 Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements or Statements-Representation Jan 2017 52.204-7 System for Award Management Oct 2018 52.207-6 Solicitation of Offers from Small Business Concerns and Small Business Teaming Arrangements or Joint Ventures (Multiple-Award Contracts) Aug 2024 52.209-2 Prohibition on Contracting with Inverted Domestic Corporations-Representation Deviation Nov 2025 52.209-5 Certification Regarding Responsibility Matters Deviation Nov 2025 52.209-7 Information Regarding Responsibility Matters Oct 2018 52.217-5 Evaluation of Options Jul 1990 852.233-70 Protest Content/Alternative Dispute Resolution Oct 2018 852.233-71 Alternate Protest Procedure Oct 2018 | - | Combined Synopsis | 09/18/2026 |
The Department of Veterans Affairs (VA), Office of Acquisition NCO 22, is conducting market research to identify qualified businesses capable of providing one (1) MVE CryoCart, Manufacturer Part Number 14448703 for the Southern Arizona VA Health Care System (SAVAHCS) in Tucson, Arizona. The requirement is specifically for the MVE Biological Solutions CryoCart, Part Number 14448703. The purpose of this Sources Sought Notice is to determine the availability and capability of interested vendors, including Service-Disabled Veteran-Owned Small Businesses (SDVOSBs), Veteran-Owned Small Businesses (VOSBs), and other small business concerns, to furnish the specified equipment. This notice is issued solely for market research and acquisition planning purposes and is not a solicitation or request for quotations. | - | Market Research | 11/24/2026 |
PROTEINSIMPLE JESS AUOTMATED PROTEIN ANALYSIS SYSTEM | - | Solicitation | 11/18/2026 |
Sources Sought Notice Sources Sought Notice Page 5 of 5 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 5 This is NOT a solicitation or request for quote. This is NOT a request for proposal. This is NOT a job advertisement for hiring employees. The VA is seeking QUALIFIED VENDORS to provide a very brief response to this notice including only just what is asked for in this notice below. This is sources sought notice to industry and the only information is posted on Contract Opportunities web page at SAM.gov. Sources sought means seeking qualified vendors. The attachments included on the Contract Opportunities page do not include any additional information. If your company is interested, please read this notice entirely and submit the required information, as requested herein. Automated Blood Culture Analyzers and Bottles Four (4) VA Medical Centers: Fort Harrison, MT, Cheyenne, WY, Grand Junction, CO and Sheridan, CO BRIEF SCOPE OF WORK (This is for information only) IMPORTANT NOTE: This Sources Sought is for market research purposes only (to determine the socioeconomic status of interested companies). No award will be made off this posting. The four (4) VA medical centers each require an automated blood culture analyzer with corresponding blood culture bottles. It is anticipated the blood analyzer would be provided to each facility for use for a base period (1 year) with four (4) additional optional years. **The current blood culture analyzer in use at each facility is the BD (Becton Dickinson) BACTEC FX40 Automated Blood Culture System** Overview of Items (5-years): Line Item # Description Unit Base Yr Qty OY#1 Qty OY#2 Qty OY#3 Qty OY#4 Qty Fort Harrison, MT 0001 Blood Culture Analyzer EA 1 1 1 1 1 0002 Blood Culture Management Computer and Software EA 1 1 1 1 1 0003 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 26 26 26 26 26 0004 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 26 26 26 26 26 0005 BOTTLE PLASTIC Myco F Lytic 50/PK PKG 3 3 3 3 3 0006 Connectivity & Workflow Management EA 1 1 1 1 1 Cheyenne, WY 0007 Blood Culture Analyzer EA 1 1 1 1 1 0008 Blood Culture Management Computer and Software EA 1 1 1 1 1 0009 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 28 28 28 28 28 0010 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 28 28 28 28 28 0011 BOTTLE PLASTIC PEDS PLUS/F 50/PK PKG 4 4 4 4 4 0012 Connectivity & Workflow Management EA 1 1 1 1 1 Grand Junction, CO 0013 Blood Culture Analyzer EA 1 1 1 1 1 0014 Blood Culture Management Computer and Software EA 1 1 1 1 1 0015 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 20 21 22 23 24 0016 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 20 21 22 23 24 0017 BOTTLE PLASTIC PEDS PLUS/F 50/PK PKG 1 1 1 1 1 0018 Connectivity & Workflow Management EA 1 1 1 1 1 Sheridan, CO 0019 Blood Culture Analyzer EA 1 1 1 1 1 0020 Blood Culture Management Computer and Software EA 1 1 1 1 1 0021 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 12 12 12 12 12 0022 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 12 12 12 12 12 0023 Connectivity & Workflow Management EA 1 1 1 1 1 0024 Remote Alert System (After Hours) EA 1 1 1 1 1 Statement of Work: 1.0 Scope of Work The microbiology department of the Pathology and Laboratory Medicine Service (P&LMS) requires a cost per bottle contract to provide new automated Blood Culture instruments for use at the Ft. Harrison campus of the VA MT Healthcare System, Cheyenne VAMC, Sheridan VAHCS, and Grand Junction VAMC. Equipment and supplies must be installed, fully approved by the station team, and ready for use no later than May 1st, 2027. The awarded contract will have a one-year base period with four annual option periods. 2.0 Tasks The vendor shall provide all automated blood culture instruments, supervision, parts, labor, software, preventative maintenance, materials, and incidentals in order to ensure fully successful blood culture test and meet or exceed all listed requirements in the specifications below. 2.1 General Requirements Requirements, as set forth in this statement of work are minimum standards and shall not be construed as limiting the overall quality, quantity, or performance of the instrument. The vendor shall maintain the performance and overall quality of all instrument systems during the period of performance to all software upgrades, equipment, maintenance, parts, and labor to ensure full functionality and currency of new automated blood culture instruments. The instrument system, based upon the specifications requested, shall be the newest and the most current model. Refurbished systems are not acceptable. The instrument must be a standard product of the manufacturer of record. The manufacturer of record is defined as a company whose main occupation is the manufacture for sale items of equipment and which: Maintains a factory production line. Maintains a stock of replacement parts for the item. Maintains engineering drawings, specifications, operating manuals and maintenance manuals. Has published and distributed descriptive literature and equipment specifications on the equipment. The analyzer cabinet/instrument shall be a countertop model fitting within the following available spaces: Montana 75 in W x 45 in D Cheyenne 45 in W x 30 in D Grand Junction 87 in W x 30 in D Sheridan 31 in W x 36 in D If the proposed analyzer does not fit the dimensions of any of the stations above, a contractor provided cart may be used if the station agrees and has the room for it. All equipment/supplies/bottles and software must be FDA-approved at time of award 2.2 System Requirements The instrument system shall meet the following requirements: Use plastic and glass culture bottles that are specific to the instrument system and the culture bottles used in the instrument should contain a neutralizing resin media for the aerobic culture bottle and a lytic broth media for the anaerobic culture bottle. + Be able to accept and analyze blood, fungal and an acid, fast, bacteria (AFB) culture bottles. Be able to accept and analyze both blood and body fluid specimens. Utilize a varied selection of blood culture bottle configurations (low volume samples; antimicrobial agent removal resins) and formulations capable of maximizing growth potential of various microorganisms (e.g. aerobic and anaerobic bacteria, fungi, and mycobacteria) shall be available. Have the capability to flag and alert the end-user of positive culture vials by simultaneous visual alert, sound alert and remote alert using existing software programs. The Sheridan VAMC lab does not run 24/7 so the contractor shall provide a system by which their AODs (Administrative Officer of the Day) can monitor the system remotely 24 hours per day. Provide self-contained, continuous, computerized, automated monitoring of blood culture bottles with immediate, active (e.g. audible alarm) notification of microorganism growth based upon pre-programmed criteria and notification of termination of maximum programmed incubation period when no microorganism growth is detected. Allow for operator extension of programmed incubation times while testing is in progress, without interruption of automatic continuous monitoring. Have the capability to monitor the blood volume in each culture bottle. Utilize sufficient safety features to avoid unnecessary exposure to biohazardous and chemical material. The exposure to and the volume of biohazardous and chemical material generated by the equipment must be minimal and require a minimum amount of handling. Have the capability to detect and document elapsed time to positivity. Have bar code reading capability to eliminate the need for manual entry of patient information for each sample. Contractor bar code formats shall meet requirements of VA lab information system software. Have the capability to scan the culture vial sequence and specimen accession label in any order. Have the capability to accept the culture vial in any available station. Have the ability to provide automated transmission of test results into the laboratory s current laboratory information system LIS. Contractor must be able to send information through Data Innovations (DI) instrument server and have DI driver available. Must provide all hardware and software needed to connect via TCP\IP protocol, as well as communicate with government VISTA protocols and system. Utilize Food and Drug Administration (FDA)-cleared software. Contain a report module that has the ability to generate epidemiology and statistical reports. Contain a data management system that allows users to monitor and analyze data. Provide printed paper results in the event of computer down time. Have the ability to electronically archive patient results. Have the ability to generate cumulative quality control (CQC) reports. 2.3 Instrument Requirements When requested, the instrument cabinet should be able to hold a minimum of 200 culture bottles Some facilities may have smaller minimum volume requirements. The vendor should have a variety of instrument sizes and types to accommodate the estimated annual volume requirement for each facility. The instrument should take up minimal space and have the ability to stack incubation cabinets on top of each other. The instrument should require only minimal maintenance by government personnel. The instrument must include an on-board programming display and be user friendly. The instrument system must include a 120-volt Uninterrupted Power Source (UPS) system that has a 30-minute backup capability in the event of electrical power interruptions. The system should also have provisions for saving data in the event that the capacity of the UPS is exceeded. The vendor shall provide all software upgrades and a field technical representative from the instrument manufacturer shall install the updated software at no charge within a reasonable time and shall coordinate with the laboratory supervisor. The instrument system shall have the ability to accept upgrades so as to accommodate the need for increased testing volume. Software must be compatible with Bruker MALDI bio-typer 2.4 Supply Requirements The vendor shall: Supply a variety of plastic and glass culture bottle types and allows flexibility in the selection of culture bottle types required based on facility needs. Shall provide customer helpline telephone numbers for VAMC laboratory technicians to the call-in routine and emergency supply request. The vendor shall supply all necessary point of contact information and ordering procedures for VAMC laboratory technicians to order reagents and other supplies for both a standing delivery schedule basis or on an as-needed basis. Fill routine and emergency supply requests when requested. Pay shipping fees for all supplies, consumables, and equipment needed to perform installation start-up testing. Provide ancillary components that are necessary for the model of equipment proposed (i.e. starter kits, tables, stands, etc.). List all reagents, controls and disposables required for operating the instrument and producing quality results as an addendum in the pricing schedule. 2.5 Repair & Maintenance Services The manufacturer shall provide technical support either by phone or on-site. Service should include all travel, parts for repair or replacement, and labor. The vendor shall provide a preventative maintenance schedule to include a minimum of one scheduled preventative maintenance visit per year. The vendor shall be responsible for the removal of the hard drive of the analyzer upon removal/upgrade of the instrument. The hard drive shall be given to the laboratory VA information system manager for disposal. The service shall include replacement or repair of all ancillary equipment (i.e. printers, monitors, UPS) necessary for the system to operate efficiently. 2.6 Pre-Installation Assessment The vendor shall provide written information detailing all maintenance, environmental, and utility requirements (electrical, dimensions of equipment, media disposal, etc.) as part of their proposal to include the following information. If the equipment proposed is particularly heavy, advisement of extra reinforcement shall be necessary. Provide dimensions of the system. List utility requirements (electrical, heat/cool, humidity, etc.) Describe testing methodology. List quality control (QC) frequency. Describe maintenance requirements for daily/weekly/monthly maintenance. Describe any environmental impact issues that instrumentation may create (water requirements, media disposal, etc.). Describe user friendliness: Describe software and/or supporting instrumentation provided with the system to maintain or improve levels of data retrieval which may be used for monitoring epidemiology trends. Describe reagent management (storage and waste). Describe ability to trouble-shoot system. Describe how system alerts user of positive and negative culture bottles. Provide list of reagent recalls/bulletins within the last two years. List reagent unavailability due to manufacturing issues within the last two years. Environmental requirements (heat/cool, humidity, light, etc.) and recommendations for instrument and testing material storage. Manufacture s maintenance requirements indicating what maintenance is performed by the end-user and what maintenance is performed by the manufacturer by providing outline or brochure outlining frequency of preventative maintenance. 2.8 Laboratory Information System (LIS)/Interface Software must be compatible with all barcode styles and have proven bi-directional interface capability with the laboratory s current LIS. The vendor must provide additional hardware (i.e. middleware) and software needed to interface the system and provide technical assistance with interfacing the instrument system. Required (additional) interface connection license(s) shall be provided at vendor cost. The instrument-LIS interface must be bi-directional. The interface must use automatic host query to download sample, IDs, test requests, and patient demographics. Automatic host query must seamlessly integrate with on-board patient sample barcode scanning and translation. The instrument interface must transmit test results to the host computer system via automatic upload. Instrument system must have computer capabilities that are compatible with the end-user s LIS software and include an LCD display monitor and printer. The vendor shall provide technical support to link the instrument to the LIS interface and ensure that the instrument system is communicating properly. Vendor must successfully interface the analyzer via a Data Innovations Instrument Manager to the VA VISTA system. Must be compatible Bruker MALDI bio-typer 2.9 Support Services: The manufacture should have the ability to provide service sufficient to meet the needs of the end-user facility, 7 days a week, business hours for all sites. A field engineer must be available within 24 hours of after the service call has been placed. All repairs to the instrument must be complete within 24 hours from the time the field service engineer arrives. The vendor s staff shall designate in writing to the contracting officer a fully qualified primary and alternate Field Service Representative who has the authority and knowledge to respond to all technical/maintenance/repair issues. Fully qualified is based upon training and experience in the field. For training, the Field Service Representative must have successfully completed a formalized training program for the equipment covered under the contract. For field experience, the Field Service Engineers must have a minimum of one (1) year of experience providing preventative maintenance and emergency repair services on the same make and model of equipment covered under this contract. The vendor shall provide 24-hour, 7 days/week telephone technical support. The vendor shall submit a legible field service report to the laboratory supervisor itemizing the preventive maintenance inspection or emergency repair services performed, including replaced parts and estimated prices required for the service call. The vendor shall coordinate on all potentially hazardous safety issues with the contracting officer and laboratory supervisor. 3.0 Installation, including Instrument Validation & Training A technical support specialist from the instrument manufacturer shall assist in equipment installation/set-up, providing all manpower, procedures, and reagents/supplies to perform validation and correlation studies [evaluation/comparison data sufficient to satisfy College of American Pathologists (CAP) standards]. The vendor must provide required statistical analysis of the validation and correlation data in an organized binder for on-site director approval. The statistical analysis must be completed within eight weeks of installation of the system. The vendor/distributor and/or the manufacturer must provide all necessary procedure manuals, troubleshooting manuals and operator manuals. The vendor shall provide primary user training for a minimum of one user per instrument with on-site basic operating and maintenance education/training performed during initial installation and when updates to the equipment are performed. Training is to include all costs related to off-site training (transportation, room and board, etc. if applicable). Any additional costs such as industrial funding fees, special shipping and handling fees, or other usage fees must be included in the contract price or identified separately in the proposal. 4.0 Delivery and Acceptance 1. All items shall be shipped F.O.B. destination to the following locations M-F, 8am-4pm, excluding holidays: FT Harrison VAMC 3717 Veterans Drive Ft. Harrison MT 59636, Cheyenne VAMC 2360 East Pershing Blvd Cheyenne WY 82001 Sheridan VAMC 1898 Fort Road Sheridan WY 82801 Grand Junction VAMC 2121 North Avenue Grand Junction CO 81501 The Contractor, its employees, agents, and subcontractors shall not be considered VA employees for any purpose of fulfilling the PWS and shall be considered employees of the Contractor. Contractor shall furnish all labor, materials, equipment, tools, shipping, transportation, insurances, licenses, certifications, and supervision necessary to provide services in accordance with this Performance Work Statement (PWS). The Contractor is responsible for all charges and fees related to disposal of materials generated by the Contractor. This is anticipated to be a commercial supply acquisition under the authority of FAR Part 12, Simplified Acquisition Procedures for Commercial Items. The products will be delivered to the following locations: FT Harrison VAMC 3717 Veterans Drive Ft. Harrison MT 59636, Cheyenne VAMC 2360 East Pershing Blvd Cheyenne WY 82001 Sheridan VAHCS 1898 Fort Road Sheridan WY 82801 Grand Junction VAMC 2121 North Avenue Grand Junction CO 81501 IMPORTANT NOTE: This RFI (Request for Information) is for information only. No award will be made from this RFI. QUALIFIED VENDOR: A qualified source has the a) necessary equipment, vehicles, personnel, resources and current operations as well as b) recent experience (within past 3 years) of performing services of a comparable size, scope and complexity, AND c) OEM certified technicians to perform services with unrestricted access to the facility during inclement weather, as well as immediate access to OEM software updates. A qualified source also has current and valid registration in System for Award Management (SAM), https://www.sam.gov). Please communicate via e-mail to Stephanie.Cahill@VA.Gov by 15:00 MST on November 20th, 2026, as to your company s ability to perform service per this brief Scope of Work. If interested, please provide the following: Provide company s capability statement describing ability to provide equipment that meets or conforms to the salient characteristics listed above *include specification or brochure documents for confirmation of equivalent products* Company s business size in relation to NAICS 334516 and socio-economic category (SDVOSB/VOSB/WOSB/Large Business): SAM UEI: FSS/GSA contract # (if applicable): **Indicate Open Market if items are not included on FSS/GSA/etc.** Estimated delivery lead time: Where are the products manufactured/COO: Only written responses, to items 1 through 6 above, will be accepted at this stage. Information is being gathered for market research purposes only. Industry exchanges and vendor teleconferences are at the discretion of the Contract Specialist. This is not a request for quotes. DISCLAIMER: This is a Request for Information (RFI) from industry in accordance with Federal Acquisition Regulation (FAR) 15.201(e) and on the requirement, that exists for the VA Medical Center(s) identified in this RFI. This is not a request for quote and not a contract. This announcement is not a request for proposals; therefore, responses to the RFI are not considered offers and cannot be accepted by the Government to form a binding contract. This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responders are solely responsible for all expenses associated with responding to this RFI. No classified information should be included in the RFI response. Should you have concerns regarding this RFI you may request to contact the Contracting Office that will be assigned this requirement by emailing the sender of this RFI. Questions must be addressed in writing to the Contract Specialist. Requests for VA-business sensitive information, to include VA budget information, VA acquisition planning information, acquisition methods, strategies and set-asides must be addressed via the VA FOIA process: https://www.va.gov/foia/ Thank you for your interest in doing business with the VA. To learn more about the VA Mission, Vision, Core Values & Goals visit https://www.va.gov/about_va/mission.asp To understand the latest updates on the Veterans First Contracting Program visit https://www.va.gov/osdbu/verification/veterans_first_contracting_program_adjustments_to_reflect_the_supreme_court_kingdomware_decision.asp To find out how to do business with the VA visit https://www.va.gov/osdbu/library/dbwva.asp | - | Market Research | 11/20/2026 |