GovChime
Notice ID: 0cfeb5ebc51c4071a1a7e2328c37a397Award NoticeAwarded

C1DZ--673-905 Construct New Morgue Minor Design - Tampa VAMC

Awarded on July 30, 2024. Full description on SAM.gov.

Awarded tounder 36C77624C0139 (source: SAM.gov award notice)• $349.3K

Overview

Posted
July 30, 2024
Notice type
Award Notice
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
NAICS
541310: Architectural Services
Agency
Department of Veterans Affairs

Notice details

Place of performance
James A. Haley Veterans' Hospital 13000 Bruce B. Downs Boulevard, Tampa, 33612-4745
Last updated
Dec 4, 2025
Award date
Jul 30, 2024
Award amount (SAM.gov award notice)
$349.3K

Identifiers

Solicitation number
36C77623R0167
Notice ID
0cfeb5ebc51c4071a1a7e2328c37a397
Award number (PIID)
36C77624C0139

Description

THIS IS NOT A REQUEST FOR PROPOSAL. THIS IS A REQUEST FOR STANDARD FORM (SF) 330 ARCHITECT-ENGINEER QUALIFICATIONS PACKAGES ONLY. ALL INFORMATION NEEDED TO SUBMIT SF 330 DOCUMENTS IS CONTAINED HEREIN. NO SOLICITATION PACKAGE, TECHNICAL INFORMATION, OR BIDDER/PLAN HOLDER LIST WILL BE ISSUED. THE GOVERNMENT WILL NOT PAY, NOR REIMBURSE, ANY COSTS ASSOCIATED WITH RESPONDING TO THIS REQUEST. THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. 1. GENERAL INFORMATION Veterans Health Administration (VHA) Program Contracting Activity Central (PCAC) is seeking sources and intends to award a firm fixed price design contract for Architect-Engineering (A-E) services for the development of complete construction documents, which include working drawings, specifications, and reports, and construction period services for Project # 673-905 Construct New Morgue at the Tampa VA Medical Center. The A-E Services contract that is anticipated to be awarded will be procured in accordance with the Selection of Architects and Engineers statute [formerly known as the Brooks Architect Engineer Act], Federal Acquisition Regulation (FAR) subpart 36.6 Architectural and Engineering Services, VA Acquisition Regulation (VAAR) 836.6, and VA Acquisition Manual (VAAM) M836.6 Architect-Engineer Services. In accordance with FAR 36.209, Construction Contracts with Architect-Engineer Firms, no contract for the construction of a project shall be awarded to the firm that designed the project or its subsidiaries or affiliates, except with the approval of the head of the agency or authorized representative. 2. PROJECT INFORMATION This project is a 100% set-aside for Service-Disabled Veteran-Owned Small Business (SDVOSB) concerns. The NAICS code for this procurement is 541310 Architectural Services and the annual small business size standard is $12.5M. A full design team is required to complete this project. The VA expects to award the anticipated A-E contract in February 2024. The anticipated period of performance for completion of design is 284 calendar days after notice of award (NOA). The VAAR magnitude of construction is between $2,000,000 and $5,000,000. Please note that the 284-calendar-day period of performance for the design completion begins with the issuance of the NOA and that a notice to proceed (NTP) will not be issued for the completion of a design project. 3. A/E SELECTION PROCESS Firms submitting SF 330s in response to this announcement, not later than the closing date and time specified herein and in accordance with submission requirements, will be considered for evaluation. The selection will be made as follows: SF 330s will be evaluated in accordance with the primary selection criteria as stated in this pre-solicitation notice. These evaluations will determine the most highly qualified firms for this particular requirement. In accordance with FAR 36.602-3(c), at least three of the most highly qualified firms will then be notified of the Government s intent to hold discussions. All firms not invited to participate in discussions will be notified at this time. In accordance with FAR 36.607(b), any requested debriefings of successful and unsuccessful firms will be held after final selection has taken place and will be conducted, to the extent practicable, in accordance with 15.503, 15.506(b) through (f), and 15.507(c). Note that 15.506(d)(2) through (d)(5) do not apply to architect-engineer contracts. Discussions will be held with the most highly qualified firms in the form of written responses. The firms invited to participate in discussions will be notified by email and provided further instructions, including any questions or topics to address. Following the completion of discussions, the firms will be evaluated and ranked based on the primary and (if necessary) secondary selection criteria. The final evaluation and ranking will consider the SF 330 submission for each firm, as well as additional information obtained via discussions. The highest rated firm will be selected to receive the solicitation and engage in negotiations. The solicitation will be issued to the highest rated firm as a Request for Fee Proposal (RFP). All SOW attachments and site-specific documentation will be provided to the highest rated firm with the RFP. A site visit will be authorized during the negotiation process. An award will then be made as long as the negotiation of rates and hours leads to a fair and reasonable determination of the final contract price. If negotiations with the highest rated firm are unsuccessful, the firm will be notified that negotiations have been terminated. Negotiations will then be initiated with the next highest rated firm, and so on until award can be made. 4. SELECTION CRITERIA: Firms responding to this notice will be evaluated and ranked using the primary and secondary selection criteria listed below. The factors are listed in descending order of importance. The evaluation will consider how each factor is addressed and how it is formatted to coincide with the selection criteria. Primary Selection Criteria: Professional qualifications necessary for satisfactory performance of required services. The architects and engineers on the firm s staff representing the project or signing/stamping drawings in each discipline must possess a minimum of five years of experience and are required to be licensed, registered, or certified by a US state, the District of Columbia, or a US territory. Disciplines requiring Florida license include Civil/Structural and Hazardous Material Abatement/Industrial Hygiene. Provide professional license jurisdiction of issue and license numbers and/or proof of licensure. At a minimum, the offeror must describe the professional qualifications and specific experience in the required disciplines. Disciplines required for this project include, but are not limited to: Architecture, Mechanical, Electrical, Plumbing, Structural, Civil, Fire Protection, Hazardous Material Abatement/Industrial Hygiene, Physical Security (must hold the Certified Protection Professional (CPP) or Physical Security Professional (PSP) certification issued by ASIS International), Cost Estimation, Project Management, and Commissioning. The evaluation will consider education, certifications, training, registration, overall and relevant experience, and longevity with the firm. Offeror must include the following statement of SDVOSB compliance when submitting the personnel proposed to perform the work under this requirement: I, [signatory authority], of [company name], certify that the SDVOSB prime contractor will not pay more than 50% of the amount paid by the government to the prime for contract performance to firms that are not certified SDVOSBs listed in the SBA certification database in compliance with VAAR 852.219-73. The information provided in sections C through E of SF 330 will be used to evaluate this factor. Do not include this information in section H, unless it is pertinent to support the information listed in the other sections. Specialized experience and technical competence in the design and construction period services for the design of an Annex and renovation of a Morgue, or related project in a hospital/lab setting. The A-E design shall conform to all post pandemic rules and regulations in the state of Florida Building Code and National Building Code. The A/E design shall also be guided by the VA TIL Design Criteria. Other specialized experience includes experience in critical path scheduling, fire protection, construction infection control protocols, energy conservation, transition, and sustainable design practices. Include no more than five Government and/or private experience in the designing of Hospital or laboratory setting projects similar in size, scope, and complexity, and experience with the types of projects above. The evaluation will consider the management approach, coordination of disciplines and engineering consultants, quality control procedures, prior experience of the prime firm and any key subcontractors working together on relevant projects, and familiarity with VA Design Guides/Manuals, Master Specifications, and other applicable standards. The information provided in sections F and G of SF 330 will be used to evaluate this factor. Do not include this information in section H, unless it is pertinent to support the information listed in the other sections. Capacity to accomplish work in the required time. The evaluation will consider the team s plan and overall ability to meet the schedule of the project, as well as the available capacity of personnel in key disciplines. Provide the team s available capacity by listing all projects awarded during the previous 12 months, including the full potential value of any current indefinite delivery contracts, and by presenting current workload percentages for required disciplines. At a minimum, include the following for each project: project name, location, award date, completion percentage, and expected completion date. The information for this factor must be provided in section H of SF 330. Please ensure the capacity applies toward the proposed team/personnel provided in SF 330. Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. CPARS data or PPQs (use attached PPQ if no CPARS data is available) must be provided for all projects submitted under Section F of the SF 330. The following information must be specified on each performance report: contract/task order number, project title, prime firm, start date, and completion date. CPARS data and PPQs do not count toward the page limitation. Government past performance information systems may be accessed. Evaluating past performance and experience may include information provided by the firm, customer inquiries, Government databases, publicly available sources, and additional projects in CPARS. Failure to provide requested data, accessible points of contact, or valid phone numbers could result in a firm being considered less qualified. Note: We recommend you contact every reference listed and let them know we may contact them for information. Their timely replies would be appreciated. The information for this factor must be provided in section H of SF 330. Knowledge of the locality. Demonstrate and describe experience in the local area and the specific knowledge of certain local conditions or project site features the experience provided. This description may include (if applicable): Any prime firm or subcontractor experience within the VISN or at the VAMC State or local construction codes, laws, or regulations If prior experience in or specific knowledge of the local area is minimal, describe how the team plans to obtain any specific knowledge of certain local conditions or project site features required for this project. The information for this factor must be provided in section H of SF 330. Construction Period Services: Describe your team s approach to providing construction period services that may include: professional field inspections during the construction period; review of construction submittals; support in answering requests for information (RFIs) during the construction period; support of construction contract changes, including drafting statements of work and cost estimates; attendance at weekly conference calls; providing minutes of meetings between the A-E, VA, and contractors; commissioning; pre-final inspection site visits; generation of punch-list reports; and production of as-built documentation. List project examples to demonstrate the prime firm s experience with construction period services. The information for this factor must be provided in section H of SF 330. Secondary Selection Criterion*: Geographic location. Location of the firm, as measured by the driving distance (300 miles) between the offeror s principal business location and the Tampa VAMC. Determination of the mileage will be based on Google Maps (https://www.google.com/maps/dir/). *The secondary selection criterion is used as a tiebreaker, if necessary, in ranking the most highly qualified firms following the completion of discussions. The secondary selection criterion will not be applied when determining a firm s SF 330 submission highly qualified or not highly qualified. 5. SUBMISSION REQUIREMENTS: The below information contains the instructions and format that must be followed for the submission of the SF 330 Statement of Qualifications: Submit ONE (1) SF 330 Statement of Qualifications to Contract Specialist Devin Russell at Devin.Russell@va.gov. This must include Parts I and II and any applicable attachments. The submission must include the SF 330, Architect-Engineer Qualifications (form is available online at http://www.cfm.va.gov/contract/ae.asp). The SF 330 submission is due by 2:00 PM ET on November 7, 2023. The SF 330 must be submitted in one email and have a file size no larger than 5 MB. No hard copies will be accepted. The subject line of the email must read: SF330 R0167 Tampa Design Project. The SF 330 submission must not exceed a total of 50 pages. This includes title page, table of contents, and any other relevant information. Any pages submitted by an offeror that exceed the limit will not be considered during the evaluation. Each page must be in Arial size 12 font, single spaced. Part II of the SF 330 and any CPARs or PPQs will NOT count toward the page limitation. A PPQ obtained for another SF 330 submission may be submitted for this project. However, if significant portions of the project have been completed since the PPQ was filled out, a new PPQ should be submitted to accurately assess the project. Firms must include the following information in section B of the SF 330 submission: 1) SAM Unique Entity Identifier 2) Tax ID number 3) Cage code 4) Primary point of contact s email address and phone number All questions must be submitted to Devin.Russell@va.gov with the subject line Questions SF330 R0167 Tampa Design Project. The cutoff for question submission is 2:00 PM ET on October 17, 2023. Questions will be answered through modification to the pre-sol notice posted to Contract Opportunities at SAM.gov. This procurement is a 100% set-aside for SDVOSB concerns. Offers received from other than SDVOSBs will not be considered. Offerors must be certified as SDVOSBs by the U.S. Small Business Administration (SBA) and visible in the Veteran Small Business Certification (VetCert) database (https://veterans.certify.sba.gov/) at the time of SF 330 submission, written response submission, and award. Failure to be certified in the VetCert database at these times will result in the offeror being deemed ineligible for award. All joint ventures must be SBA certified at the time of SF 330 submission, written response submission, and award and must submit agreements that comply with 13 CFR 128.402 prior to contract award. All prime firms must meet the NAICS code requirement specified in this notice. The Contracting Officer will verify the NAICS code in VetCert. Failure to meet the NAICS code requirement may result in the rejection of the SF 330 submission. SF 330 submissions received after the date and time specified will not be considered. Late proposal rules per FAR 15.208 will be followed for late submittals. Firms not providing the required information may not be evaluated. All information must be included in the SF 330 submission package. It is the offeror s responsibility to check the Contract Opportunities website at SAM.gov for any revisions to this announcement prior to submitting their SF 330.

Full description on SAM.gov

Award Overview

Award Number

36C77624C0139

Award Amount (SAM.gov award notice)

$349.3K

Award Date

Jul 30, 2024

Awardee

Awardee UEI

W1PDKFN8HBF5

Awardee CAGE Code

64YA1

Original Solicitation

Notice ID: 0cfeb5ebc51c4071a1a7e2328c37a397

Posted Date: Jul 30, 2024

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

5
  • 36C25027C0022
    RDC JPA ARCHITECTURE, L.L.L.P.
    Department of Veterans AffairsNAICS 541310
    $190.4KSigned Nov 4, 2026
  • 36C24821P1893
    RDC/JOHN POE ARCHITECTS, L.L.L.P.
    Department of Veterans AffairsNAICS 541310
    $182.0KSigned Oct 15, 2026
  • 36C77625C0027
    RDC JPA ARCHITECTURE, L.L.L.P.
    Department of Veterans AffairsNAICS 541310
    $1.2MSigned Sep 29, 2026
  • 36C25023C0045
    RDC/JOHN POE ARCHITECTS, L.L.L.P.
    Department of Veterans AffairsNAICS 541310
    $130.8KSigned Aug 28, 2026
  • 36C25023C0195
    RDC/JOHN POE ARCHITECTS, L.L.L.P.
    Department of Veterans AffairsNAICS 541310
    $89.3KSigned Aug 28, 2026

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C77623R0167
  1. Pre-Solicitation
  2. Awarded

This opportunity has been awarded.

  1. Pre-SolicitationOct 4, 2023

    C1DZ--673-905 Construct New Morgue Minor Design - Tampa VAMC

    Notice 68cb4bb435684087862a784e3d37a48f on SAM.gov

  2. AwardedCurrentJul 30, 2024

    C1DZ--673-905 Construct New Morgue Minor Design - Tampa VAMC

    Notice 0cfeb5ebc51c4071a1a7e2328c37a397 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
This procurement is restricted to Service Disabled Veteran Owned Small Business (SDVOSB) firms located within a 300 mile radius of the Battle Creek VA Medical Center, 5500 Armstrong Rd, Battle Creek, MI 49037. The mile restriction is in compliance with VAAR 805.207 (b). This requirement is being procured in accordance with the VAAR 836.606-73 as implemented in FAR Subpart 36.6. Description of work to be performed includes: Architect-Engineering services are required for Schematics, Design Development, Construction Documents, Technical Specifications, Construction Period Services, Site Visits, Cost Estimates, and all other related information for Project #515-14-123, Replace Fire Alarm System. The project will include design work for the preparation of 100% complete working drawings and contract documents using edited VA Master Specifications to complete the following: I. STATEMENT OF AE TASKS A. The AE shall furnish all services for a complete schematic design, design development, construction documents, bid documents, site visits, cost estimates, as-built documentation, and construction period services and all other related information for project 515-14-123 Replace Fire Alarm System for 30 buildings at the Battle Creek VA Medical Center in Battle Creek, MI. 1) Necessary site survey work such as verifying existing conditions, verifying record drawings, and verifying and analyzing utility systems shall be accomplished in conjunction with preparation of Schematic Design, and Design Development. 2) The A/E shall design a station wide fire monitoring system to be installed parallel to the existing system. Redundant monitoring: primary at building 25 and redundant at police department building 2. The system shall be designed to be monitored by wireless network including transmitters, receivers, and transceivers, including all permits, and FCC application for equipment frequency allocation. 3) The A/E shall evaluate each building to determine which field devices need to be added in accordance with current codes. 4) The AE will be required to attend in person (or Senior Delegate of AE) to pre-bid meetings, a pre-construction meeting, project construction meetings and a final inspection meeting. There will also be various construction site meetings that will require a representative of the AE. 5) AE will provide meeting notes / minutes for meetings and conference calls. 6) The A-E shall provide competent design and construction period services utilizing individuals who are adequately knowledgeable of the various design disciplines including but not limited to architectural and engineering of structural, mechanical, electrical, and special systems as required by the project. Changes in personnel from those who are proposed in negotiations, interviews, kick-off meeting, and/or A-E submission forms must be approved in writing. The registered individuals who will stamp the completed documents shall accomplish engineering design work. B. The AE shall provide cost estimation, project scheduling & phasing, bid period and construction period services as further described in the contract. Estimates shall have a full itemized line item breakout commensurate with the degree of design accomplished. At the Schematic Design phase, square foot estimates would be adequate. As the design progresses in detail, so the estimate would progress in detail. C. The AE shall provide bid documents in both hard paper copies and electronic format. Electronic format shall include AutoCAD and Microsoft Word/Excel as well as PDF format for all. Final PDF of the construction drawings shall include the professional stamp. D. AE shall design construction to phase and coordinate work to minimize disruptions to medical center operations. Outages shall be minimized and temporary conditions planned to maintain critical utility systems. Suitable space/access for mechanical room equipment maintenance must be maintained throughout construction. To keep the number of outages to a minimum, group common work. Phasing of interruptions shall be clearly indicated on the construction documents. E. A-E shall design within funding limitations. AE shall coordinate cost control measures with COR to design within funding limits. Cost control alternatives shall be explored in Design Development (DD's). The AE is required by national VA directive to include a 20% bid deduction. F. Review AE Quality Alerts from the TIL. Design completion timeframe of 190 days after receipt of the Notice to proceed. The A/E firm shall also be required to perform construction period services after award of the construction project contract. In accordance with FAR 36.204, the estimated magnitude of the resulting construction project is between $1,000,000 and $5,000,000. Qualifications (SF330) submitted by each firm for Project #515-14-123 for "Replace Fire Alarm System" will be reviewed and evaluated based on the following criteria: Prospective firms are required to address all selection criteria within submitted SF330 packages using additional pages as required and SF 330 submissions including any additional pages are not to exceed fifty (50) pages. Selection criteria shall be in accordance with Federal Acquisition Regulation (FAR) Part 36.602-1 and VA Acquisition Regulation (VAAR) Part 836.602-1 as follows: (1) Professional Qualifications: the qualifications of the individuals which will be used for these services will be examined for experience and education and their record of working together as a team. The specific disciplines which will be evaluated are architectural, engineering, and estimating. (2) Specialized Experience and Technical Competence: specific experience and technical skill in the type and scope of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. (3) Capacity to Accomplish the Work: the general work load and staffing capacity of the design office which will be responsible for the majority of the design and the ability to accomplish the work in the required time will be evaluated. (4) Past Performance: the past performance of the firm on contracts relevant in scope to the advertised project that were accomplished with the Department of Veterans Affairs, other Government agencies, and private industry in terms of cost control, quality of work, and compliance with performance schedules will be examined. Project past performance references older than 3 years will receive a lesser score than those references for projects accomplished within the past 3 years. (5) Location of Design Firm: the geographic proximity of each firm to the location of the VA Medical Center will be evaluated. This criterion will apply to the office from which the majority of the design services will be performed. Scoring will be based off of the proposed location of the prime contractor firm for this category. Scoring shall be as follows: within 75 miles - Excellent (Blue); 76-125 miles - Very Good (Green); 126-175 miles - Acceptable (Yellow); 176 - 225 miles - Marginal (Orange); 226 - 300 miles - Poor (Red). (6) Claims and Terminations: record of significant claims against the firm or terminated contracts because of improper or incomplete architectural and engineering services will be examined. (7) Reputation in A-E Community: reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness. (8) Specific experience and qualifications: of personnel proposed for assignment to the project and their record of working together as a team. FAILURE TO CLEARLY ADRESS ALL EIGHT LISTED EVALUATION CRITERIA AND INFORMATION REQUIRED BY THE SUBMISSION REQUIREMENTS BELOW MAY RESULT IN REJECTION OF SF330. The NAICS Codes for this procurement is 541310 Architectural Services and small business size standard of $7.5 Million. Award of a Firm Fixed Price contract is anticipated. Anticipated time for completion of design is approximately 190 calendar days including time for VA reviews. The A/E firm shall also be required to perform construction period services if award of a construction project contract is made. DATABASE REGISTRATION INFORMATION: VERIFICATION OF STATUS OF APPARENTLY SUCCESSFUL OFFEROR THIS ACQUISITION IS 100% SET-ASIDE FOR QUALIFIED SERVICE DISABLED VETERAN OWNED SMALL BUSINESS AE FIRMS IN COMPLIANCE WITH VAAR 852.219.10. ONLY BUSINESSES VERIFIED AND LISTED IN THE VENDOR INFROMATION PAGES DATABASE (http://www.vetbiz.gov) SHALL BE CONSIDERED. SYSTEM FOR AWARD MANAGEMENT (SAM): Federal Acquisition Registrations require that federal contractors register in the System for Award Management (SAM) database at www.sam.gov and enter all mandatory information into the system. Award cannot be made until the contractor has registered. Offerors are encouraged to ensure that they are registered in SAM prior to submitting their qualifications package. THE EXCLUDED PARTIES LIST SYSTEM (EPLS): To ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and 1128A of the Social Security Act regarding federal health care programs, the contractor is required to check the Excluded Parties List System (EPLS) located at www.sam.gov for each person providing services under this contract. Further the contractor is required to certify that all persons listed in the qualifications package have been compared against the EPLS list and are NOT listed. During the performance of this contract the Contractor is prohibited from using any individual or business listed on the List of Excluded Individuals/Entities. E-VERIFY SYSTEM: Companies awarded a contract with the federal government shall be required to enroll in E-Verify within 30 days of the contract award date. They shall also need to begin using the E-Verify system to confirm that all of their new hires and their employees directly working on federal contracts are authorized to legally work in the United States. E-Verify is an Internet-based system that allows an employer, using information reported on an employee's Form I-9, to determine the eligibility of that employee to work in the United States. There is no charge to employers to use E-Verify. (FAR 52.222-54) Qualified A-E firms are required to respond if interested by submitting one (1) original completed Standard Form 330 qualification package Parts I and II to include all consultants (form available on-line at: http://www.gsa.gov/portal/forms/download/116486) Must include in Part I Section H an organizational chart of the firm (excludes consultants) and a design quality management plan. Submission information incorporated by reference is not allowed. All submissions must be bound in some manner (spiral, wire, binder, etc.) and a CD copy of the Standard Form 330. Completed SF330s can be delivered to Battle Creek VA Medical Center, Attn: Craig Jenkins, Contract Specialist, NCO 10 West Contracting Office (90VC), Building 9, 5500 Armstrong Rd, Battle Creek, MI 49037, no later than 3:00 p.m. EDT, April 11, 2016. Outermost envelope or packaging shall clearly identify Solicitation number and project. Information shall be submitted via commercial express service. No hand carried deliveries. Telegraphic, email, and facsimile forms are prohibited. All submissions must be bound in some manner (spiral, wire, binder, etc.). Award of any resultant contract is contingent upon the availability of funds. No solicitation document is available and no other information pertaining to project scope, etc. is available at this time. Any request for assistance with submission or other procedural matters shall be submitted via email only (craig.jenkins@va.gov) telephone inquiries will not be honored. After the evaluation of SF330 submissions in accordance with the evaluation criteria, three or more of the most highly qualified firms will be chosen for interviews to present their approach to the design to arrive at selection of the number one firm for negotiations. The contract is anticipated to be awarded in JUNE/JULY 2016. The Government will not pay nor reimburse any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement.
-Pre-Solicitation04/11/2006
Project 652-322 | A/E Design Refresh & CPS Services for CLC | Richmond, VA
-Special Notice10/29/2026
This is a pre-solicitation notice only; do not respond. The Veterans Health Administration (VHA), Network Contracting Office (NCO) 10, requires Sterile Processing Service Water Testing Services for the Marion, Fort Wayne, and Jackie Walorski VA sites in Indiana. The Government intends to publish a 100% set-aside solicitation for Service-Disabled Veteran-Owned Small Businesses on or about 11/25/2026. The solicitation will require the Contractor to furnish a quote providing all information requested in the Instructions to Offerors for Testing Laboratories and Services. The applicable NAICS Code is 541380 Testing Laboratories and Services with a size standard of $19.0 Million. Responses will be evaluated using comparative evaluation under FAR Parts 12 and 13; see solicitation for specific criteria. The resulting award will be a Base with Four Option Years, Firm Fixed Price contract. The closing date for receipt of offers is 12/10/2026 at 01:30 PM ET. All solicitation documents may be downloaded on the date of issuance through Contracting Opportunities via Sam.gov. Any amendments will be posted only on this website. The offeror is responsible for verifying the number of amendments issued. Offerors will have an opportunity to ask questions; details will be provided in the posted solicitation. After the questioning period closes, the Government will post responses to all questions on SAM.gov via a solicitation amendment within 3 business days. Phone calls will not be accepted. No site visit will be held. All offerors shall ensure registration is active, current, and accurate in SAM and includes NAICS code 541380 at the time of RFQ submission through award. Point of Contact: Eric Sweatt, Contract Specialist eric.sweatt@va.gov
-Pre-Solicitation12/10/2026
This is a pre-solicitation notice only; do not respond. The Veterans Health Administration (VHA), Network Contracting Office (NCO) 10, requires Sterile Processing Service Water Testing Services for the Marion, Fort Wayne, and Jackie Walorski VA sites in Indiana. The Government intends to publish a 100% set-aside solicitation for Service-Disabled Veteran-Owned Small Businesses on or about 11/25/2026. The solicitation will require the Contractor to furnish a quote providing all information requested in the Instructions to Offerors for Testing Laboratories and Services. The applicable NAICS Code is 541380 Testing Laboratories and Services with a size standard of $19.0 Million. Responses will be evaluated using comparative evaluation under FAR Parts 12 and 13; see solicitation for specific criteria. The resulting award will be a Base with Four Option Years, Firm Fixed Price contract. The closing date for receipt of offers is 12/10/2026 at 01:30 PM ET. All solicitation documents may be downloaded on the date of issuance through Contracting Opportunities via Sam.gov. Any amendments will be posted only on this website. The offeror is responsible for verifying the number of amendments issued. Offerors will have an opportunity to ask questions; details will be provided in the posted solicitation. After the questioning period closes, the Government will post responses to all questions on SAM.gov via a solicitation amendment within 3 business days. Phone calls will not be accepted. No site visit will be held. All offerors shall ensure registration is active, current, and accurate in SAM and includes NAICS code 541380 at the time of RFQ submission through award. Point of Contact: Eric Sweatt, Contract Specialist eric.sweatt@va.gov
-Pre-Solicitation12/10/2026
Contractor shall provide all labor, supplies, equipment, and supervision necessary to provide Wastewater Effluent Laboratory Analysis Services to the Aleda E. Lutz VA Medical Center described herein. Wastewater Effluent Laboratory Analysis Services include, but are not limited to sample preparation, collection, and storage; transportation of wastewater effluent samples to a laboratory, performance of analytical testing; reporting of analytical test results; and consultative services.
-Solicitation11/06/2026

Additional Details

Solicitation Number

36C77623R0167

Archive Date

Nov 6, 2024

Office Address

INDEPENDENCE, OH, 44131