GovChime
Notice ID: 1eea55765ad247c289c5e7f531155707Solicitation

Y1AZ--953-MM22-002: Site Improvements - Committal Shelter, Fort Sheridan National Cemetery

Archived on August 7, 2022. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
4:00 PM UTC−04:00
Posted
June 29, 2022
Notice type
Solicitation
NAICS
236220: Commercial and Institutional Building Construction
Agency
Department of Veterans Affairs

Notice details

Office
NATIONAL CEMETERY ADMIN (36C786)
Place of performance
Department of Veterans Affairs National Cemetery Administration Fort Sheridan National Cemetery Vattman Road, Lake Forest, 60035
Last updated
Dec 6, 2025

Identifiers

Solicitation number
36C78622B0009
Notice ID
1eea55765ad247c289c5e7f531155707

Description

CONTINUATION PAGE AMENDMENT 0001 Request for Information (RFI) Responses: The following Request for Information (RFI) questions have been submitted to the Contracting Officer regarding this solicitation. The questions and responses represent all questions submitted to the Contracting Officer prior to the deadline established in the Solicitation. The following questions and responses are provided for bidder s information and use. RFI 1. Can you provide the Bid Opening telephone conference call in information? Response: The Bid Opening telephone conference call in information is: Call Line: 872-701-0185 Conference ID: 580 703 768 # RFI 2. Can you provide a site plan to show new asphalt placement, sidewalks and building location with dimensions? Response: See attached Site Plan and Cemetery Map RFI 3. Confirm the Size of the proposed Pole Building. Response: The discrepancy seems to be with the size of the storage building, the building dimensions stated in the SOW is too large for the location. The correct size as shown in the prefab storage example is 24 x 18 . RFI 4. Should the exterior walls and roof be insulated or non-insulated? Response: They shall be non-insulated. RFI 5. Is there a Plat Survey for the site that shows grave sites, drainage, utilities? If so, please provide. Response: See attached Reference drawings. RFI 6. Is there a drainage plan for the site? If so, please provide. Response: No, there is no drainage plan for this site. However, the document Pages from 124810 Fort Sheridan Cemetery Road Repaving has some drainage information that may be helpful. RFI 7. As-Built Drawings from Mound City Cemetery Cover sheet shows 41 pages of drawings there are only 5 actual drawings. Request copies of the remaining drawings for evaluation. Response: Note that the drawings provided are for informational purposes, are from a previously built committal shelter, and are to be used as a reference guild to building the new committal shelter at Ft. Sheridan National Cemetery. The missing drawings are irrelevant to this project and were intentionally deleted from the file. RFI 8. Is there a Plat Survey for the site that shows grave sites, drainage, utilities? If so, please provide. Response: See attached Reference Drawings. RFI 9. What is the location for the storage shed? Response: See attached Reference Drawings. RFI 10. What are the specifications for the concreted pad under the storage shed? Response: Refer to the details included in the specifications for Heavy Duty Applications. RFI 11. Has the size and material of the storage shed changed from the SOW, (ExSel 4205 sized 25 x 50 , with 15 6 eave height)? Response: See attached Reference Drawings. RFI 12. The cemetery backs up to the Reserve Center, Can the Reserve Center parking lot be used to gain access to the storage shed location and/or be used for the Material Laydown area? Response: Note that the Reserve Center parking lot is Not part of the cemetery and therefore that cemetery has not rights or say on the use of the parking lot. The COR can provide the POC information for the Reserve Center upon formal request, of which it will be up to the Contractor to make contact and work out a temporary usage Memorandum of Understanding (MOU) with the Reserve Center. The Contractor would need to provide a detailed plan to the NCA that shows and ensure that the Reserve Center training activities will not affected by the Contractor s work/activities. If the Contractor s work/activities in anyway causes an impact to the training, the answer will be NO. In regards to the Material Laydown area, the cemetery will provide such an area on cemetery property. RFI 13. Is the roadway to be repaved only in the circle, or does it include the one-way paths that run out from the circle? Response: See attached Reference Drawings. RFI 14. Is it required to include a Fee for an architect for drawings of committal shelter and storage shed in order to provide as-builts to the customer at the end? Response: If required, an architect fee should be inclusive in bidders total bid price/cost. RFI 15. Solicitation Page 14 of 91 Section F paragraph c Contractor shall build a dedicated committal service shelter drive or pull-off area to provide parallel parking for interment services. A small loop drive adjacent to the shelter, wide enough for parking three (3) vehicles abreast. Small loop drive adjacent to shelter is this to be concrete or asphalt? What are the dimensions? On the map, please show the A small Loop drive adjacent to the shelter, wide enough for parking three (3) vehicles abreast; what is the size and construction composition of the Loop and should the Loop provide parallel parking for interments services? Response: A separate loop drive is not necessary. The existing refinished asphalt road will be used. RFI 16. Solicitation page 13 of 91 and Spec Attachment - Eave height on prefab building is to be 15 6 or ? Response: Use the Menards design and buy estimate included in the solicitation for building dimensions RFI 17. Drawing page A101 - 2x6 wood decking on reflected ceiling plan Type of wood (species) to use? Response: Select Structural No. 2 grade and any of the following species: 1. Hem-fir (north); NLGA. 2. Mixed southern pine; SPIB. 3. Spruce-pine-fir; NLGA. RFI 18. Drawing page A101 - How large is the ceiling fan? Response: No Ceiling Fan There is no electrical equipment in this project because no available power RFI 19. Drawing page A101 Detail A - What size and type are the downspouts? Response: Prefabricated structure manufacturer to include properly sized downspouts in submittal for COR approval RFI 20. Drawing page A101 Detail D and Technical Specifications page 216 of 221 What is the manufacturer type and size of the wall mounted ash receptacle. Response: An Ash Urn receptacle is not required RFI 21. Spec Attachment page 5 of 14 and Solicitation page 13 of 19 Should it be 6/12 roof pitch or 3/12 roof pitch? Response: 6/12 Roof pitch per the design and buy estimate included in the solicitation END OF AMENDMENT 0001

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

May 24, 2023

NAICS

236220

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C78622B0009
  1. Pre-Solicitation
  2. Solicitation

Award typically follows within 30–90 days after the response deadline. (estimate)

  1. Pre-SolicitationApr 27, 2022

    Y1AZ--953-MM22-002: Site Improvements - Committal Shelter, Fort Sheridan National Cemetery

    Notice 9acd73b877ff43f8ad6fc8cb0c3822fc on SAM.gov

  2. 2×
    SolicitationCurrentMay 20, 2022

    Y1AZ--953-MM22-002: Site Improvements - Committal Shelter, Fort Sheridan National Cemetery

    Notice 1eea55765ad247c289c5e7f531155707 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Solicitation Number: 36C78627R0010 Project Number: 890CM3013 Description: Design Build (DB) Services for Renovation of Historic Lodge/Administration Building at Fort McPherson National Cemetery The Department of Veterans Affairs (VA), National Cemetery Administration (NCA) Central District is currently seeking firms with the ability to provide Design Build (DB) Services for Renovation of Historic Lodge/Administration Building at Fort McPherson National Cemetery Statement of Work: The purpose of this project is to provide design and construction for the renovation of the historic Fort McPherson National Cemetery Lodge Building, located at 12004 S Spur 56A Maxwell, NE 69151-1166. The design goal is to be respectful of the original designs developed by the office of the Quartermaster General of the Army, Montgomery C. Meigs, while allowing the updated use of the lodge as modern and efficient office space. The Fort McPherson Cemetery remains active, and visitation occurs regularly. The bulk of public interaction occurs at the historic Lodge/Administration building and there is need to accommodate visitors other than staff and NCA personnel. Barrier-free accessible visitor restrooms are provided in an adjacent building. The proposed interventions will respect the historic character of the lodge, and its regional variations, while providing enhanced occupant and visitor experience. Accommodations for barrier-free access must be integrated in a discreet fashion and not adversely impact the overall perception of the historic character of the lodges. Finally. proposed treatments must meet a 50-year life cycle performance goal, under regular routine maintenance conditions. Although proposed building systems may be residential in scale, they should meet energy efficiency standards. The Design Build (DB) Contractor shall provide Architectural and Engineering disciplines for the preparation of construction documents for the purpose of completing the construction project. The DB Contractor shall be responsible for the quality, accuracy and completeness of the documents required to complete the SOW. Requirements contained herein are minimums; each discipline performing engineering services for this contract shall meet current industry standards for the content and quality of deliverables. The D/B Contractor shall be responsible for coordinating the documents and for producing a complete set of construction documents in accordance with professional practices. Complete and accurate coordination between the disciplines and quality control of all consultants work shall be required. All drawings require a professional license seal and signature by the discipline responsible for the work. The D/B Contractor shall be responsible for ensuring that the quality of construction and materials complies with the Construction Documents reviewed and accepted by the Government. PROJECT SCOPE AND DESIGN CRITERIA (Survey, design, engineering, and construction contract is to include all design, engineering services, and construction associated with items 7.1 through 7.5). 7.1. The Secretary of the Interior Standards for Restoration and the Standards for Rehabilitation will be applied to the building envelope and primary interior spaces as follows: 7.1.1. Restoration of exterior brick and stone masonry. Additional survey of the exterior masonry was conducted by Schnabel Conservation, Masonry Conservator. The updated findings (Appendix A) inform the proposed scope of Work. 7.1.2. New slate roofing, sheet metal roofing, and associated copper flashing and gutter lining. 7.1.3. New wood windows and doors matching the original in design and meeting contemporary performance standards. 7.1.4. Remodeling of enclosed porch to provide a conditioned space, with the new wood frame and railing concealing the fame of the glazed storefront assembly beyond. This will include new, period appropriate wood stairs and railing. 7.1.5. New period appropriate interior wood doors, and new interior wood trim at windows, doors and wall base, typical first and second floors. 7.1.6. Refinishing of existing wood flooring at first and second floors. 7.1.7. New built-in window seats/storage at second floor windows. 7.1.8. New period appropriate mantel at primary first floor office. 7.1.9. New period appropriate light fixtures at porch, and first floor main office. 7.2. The Secretary of the Interior Standards for Rehabilitation will be applied to secondary and tertiary spaces, as follows: 7.2.1. Barrier-free access at the main entrance with the incorporation of FlexStep by LiftUp, a 2-in-1 stairlift and steps solution which can be configured as a flight of stairs, and then be transformed into a platform lift on an as-needed basis. (Product data follows this section). 7.2.2. New telecom room in basement. 7.2.3. New secure storage room and remodeling of break room/kitchen at first floor. 7.2.4. New bathroom at second floor. 7.2.5. New HVAC equipment and duct chases and soffits at second floor. 7.2.6. New electrical conduits and It/telecom outlets for workstations. 7.3. Contractor furnished, installed, and commissioning of a temporary staff trailer to support cemetery operations during construction. Contractor must support relocation of staff and potentially the Gravesite Locator during construction, and as follows: 7.3.1 The Contractor shall provide delegated design, delivery, installation, utility connection, and commissioning of a temporary occupied trailer facility for use by cemetery staff. Requirements must follow the Architectural Barriers Act (ABA) Standards and all applicable state/local codes. 7.3.2. Trailer modules must be fully skirted with treated wood framing, ventilation, and access panels for sanitary tank servicing. 7.3.3. Provide centralized heating & cooling maintaining 70 80°F, humidity at 50% (AC season). Provide appropriate HVAC units (e.g., Bard wall-mounted units with heat strips) and dedicated split system for telecom equipment. Provide restroom exhaust fans and insulated ductwork. 7.3.4. Provide temporary power connection, including new service meter/disconnect if required. Electrical requirements to be identified by Contractor and coordinated with VA. 7.3.5. Provide power/data for a minimum of three (3) staff workstations and GovernmentFurnished Gravesite Locator (GSL) kiosk installation at the trailer. Breakroom/kitchenette and restroom required in the staff trailer. 7.3.6. Additional admin trailer locations may require survey, grading, utility tie-ins, geotechnical work, and civil design depending on final location. 7.4. New Backup Power Generator: Contractor furnished, installed and commissioned new power generator and fuel storage to provide 72 hour backup power supply for all buildings in the Maintenance and Administration Building complex. At a minimum the generator will provide backup power for the Historic Lodge/Administration Building, Public Restrooms, and Maintenance Building. 7.5 Furniture, Fixtures and Equipment (FF&E) Bid Package: The FF&E scope includes planning, specification, procurement support, delivery, installation, and commissioning. Assemble Issue-for-Bid (IFB) documents for the Government: itemized schedules, cut sheets, performance criteria, warranty terms, installation requirements, services (delivery, staging, assembly, anchoring, protection), and phasing plans aligned to VA and construction contract procedures. All services performed by the contractor must adhere to National Cemetery Administration standards. Period of Performance The Contractor shall complete all work including submittals, reviews, quality control, repair/construction services, punch list corrections, clean up, invoicing and closeouts documentation submittal within five hundred and forty (540) calendar days from Government issuance of the Notice to Proceed. Place of Performance Department of Veterans Affairs National Cemetery Administration Fort McPherson National Cemetery 12004 S Spur 56A Maxwell, NE 69151-1166 The Product Service Code (PSC) for this procurement is Y1AA Construction of Office Buildings. The North American Industry Classification System (NAICS) code for this procurement 236220 Commercial and Institutional Building Construction, and the business size standard is $45.0 Million. The magnitude of construction for this project is Between $1,000,000 and $5,000,000. per RFO FAR 36.204. This Government intends set aside the project for Set-Aside for Service-Disabled Veteran Owned Small Business (SDVOSB) concerns. The SDVOSB must be considered small under the relevant NAICS code and must be registered and verified in the following websites: those desiring to receive an award from this solicitation must be registered at https://search.certifications.sba.gov/. Companies must have the Certified Veteran Enterprise (CVE) seal on their registration to be considered for an award. The SBA database https://search.certifications.sba.gov/ will be checked both upon receipt of an offer and prior to award; firms must be currently registered in the System for Award Management (SAM) database at www.SAM.gov and have completed online Representations and Certifications prior to contract award. Capability statement as it pertains to the Statement of Work are Highly encouraged since they will they will assist in determining if the project should be set aside for set aside for Service-Disabled Veteran-Owned Small Business (SDVOSB). Interested SDVOSBS can submit their capability statement that include complete address, phone & fax number of contacts to no later than Tuesday, November 24, 2026, at 10:00 am EST to Richard Adu at Richard.Adu@va.gov. All information submitted by respondents to this source sought is voluntary. This source sought notice is not to be construed as a commitment by the Government, nor will the Government reimburse any costs associated with the submission of information and Quotes in response to this notice. Respondents will not individually be notified of the results of any Government assessments. The Government s evaluation of the capability statement documentation received will factor in any possible forthcoming solicitation. -End of Document-
82%
Market Research11/13/2026
Presolicitation Notice Page 4 of 4 Page 1 of 3 This is NOT a Request for Proposal (RFP) Pre-Solicitation Notice, 36C10F26R0054, National Center for Warrior Independence Multiple Task Order (MATOC) IDIQ In response to EO 14296, Keeping Promises to Veterans and Establishing a National Center for Warrior Independence, The Department of Veterans Affairs (VA), Office of Construction and Facilities Management is issuing a Pre-Solicitation Notice for the Two-Phase Design-Build Solicitation Number 36C10F26R0054, National Center for Warrior Independence Multiple Task Order Contract (MATOC). Under this RFP, and in accordance with RFO 36.101-2(b), following the evaluation of Phase I proposals, the Contracting Officer will select the most highly qualified offerors up to three, unless the Government determines that a greater number is in its best interests, and via an amendment to the solicitation invite those offerors to submit Phase II proposals for the Seed Task Order Construct Administration Building 306 . The Seed Task Order, titled Construct Administration Building 306, will be evaluated during Phase II of this solicitation. In Phase II, Successful Phase I Offerors will be required to submit both technical and price proposals for this initial seed task order. Phase I and Phase II Evaluation Criteria, as well as any potential future projects will be specified in the official Request for Proposal. The Period of Performance is for a period of no more than 730 days after issuance of the Notice to Proceed. The project will involve demolition, design, and construction of a new facility to replace Building 306, delivering a new 40,000 square foot facility that consolidates administrative and operational space for VA Care, Treatment, and Rehabilitation Services (CTRS), Community Engagement and Reintegration Services (CERS), Behavioral Health, Mental Illness Research, Education, and Clinical Center (MIRECC), Geriatric Research, Education, and Clinical Centers (GRECC), Geriatrics and Extended Care (GEC), and Center for Development and Civic Engagement (CDCE). These programs currently occupy space within Buildings 258, 257, and 306 on the West Los Angeles VAMC campus and their relocation to a new facility would support future Veteran Housing initiatives within those buildings. Temporary canteen services will be provided through the end of 2028 to maintain continuity of operations. Upon establishment of temporary services, the existing Building 306 will be demolished, and site preparation will commence. The Government intends to award a maximum of three MATOC IDIQ contracts to the offerors whose Phase II proposals represent the best overall value. Â The seed task order "Construct Administration Building 306" will be awarded exclusively to the highest-rated awardee. Â All MATOC awardees will be eligible to compete for subsequent task orders. Future competition for task orders under this IDIQ will be restricted to the firms awarded NCWI MATOC IDIQs in accordance with RFO 16.507-2, Fair opportunity procedures. The contract is estimated to be awarded on December 11, 2026. NOTICE TO PRIME (GENERAL) CONTRACTORS: The offeror must be registered in the System for Acquisition Management database at https://sam.gov/ prior to award. SOLICITATION and AMENDMENTS: Prospective Offerors must obtain copies of solicitation documents from https://sam.gov/ , which will be available on or about July 31, 2026. By registering at https://sam.gov/ , the Offerors will have access to downloading plans, specifications and amendments, which will be available only in Adobe PDF electronic format. The Offerors must be registered in https://sam.gov/ and have a Unique Entity Identifier (UEI) Number to download documents. By registering, you will be notified by e-Mail of any new amendments that have been issued and posted. No other notification of amendments will be provided. Potential Offerors are advised that they are responsible for obtaining and acknowledging any amendments to the solicitation. There will be no public bid opening. All Offerors must ensure that their firms have the ability to provide both 100% Performance and Payment Bonds. In addition, the Offerors will be required to submit a bid guarantee with their proposal. The proposals will be evaluated and award made utilizing the Best Value, Trade-Off method per Revolutionary FAR Overhaul (RFO) 15.103-1. Offerors are advised award may be made without discussion. The estimated due date of Proposals for Phase I will be 5:00PM (ET) on September 01, 2026. Firms eligible to participate in Phase II will be notified via solicitation amendment. If you have any questions, please contact Gerald Brusaw at 224-428-3135 or via email at Gerald.brusaw@va.gov.
80%
Pre-Solicitation09/01/2026
Solicitation Number: 36C78627B0001 Project Number: 939-MM26-0A2 Description: Covered Office Space at Northwoods National Cemetery This notice is provided for information purposes only and does not constitute a request for Bid, Proposal, or Quote. The Department of Veterans Affairs (VA), National Cemetery Administration (NCA) intends to issue solicitation number 36C78627B0001 entitled, Covered Office Space at Northwoods National Cemetery on or about October 30, 2026, unless additional notice is given, or this notice is modified or cancelled. Statement of Work: The construction contractor shall provide all labor, management, materials, tools, equipment, and services necessary to construct project number 939-MM26-0A2 per the Statement of Work, Specifications, Drawings, and related construction documents. Construction will take place at Northwoods National Cemetery, located at 4520 Lakewood Road, Harshaw, WI 54529-9404 and is as follows: The Contractor shall construct a single-floor, approximately 500 SF covered office space at Northwoods National Cemetery, Harshaw, WI, in accordance with AE drawings and specifications. The building will host two permanent workstations and provide flexible open space for future needs. Installation of all work shown on the plans and described in the specifications including but not limited to construction of covered office space and related sitework as shown in construction documents that will be issued with the solicitation. All services performed by the contractor must adhere to National Cemetery Administration standards. Period of Performance The Contractor shall complete all work including submittals, reviews, quality control, repair/construction services, punch list corrections, clean up, invoicing and closeouts documentation submittal within one hundred and eighty (180) calendar days from Government issuance of the Notice to Proceed. Place of Performance Department of Veterans Affairs National Cemetery Administration Northwoods National Cemetery 4520 Lakewood Road Harshaw, WI 54529-9404. The Product Service Code (PSC) for this procurement is Y1AA Construction of Office Buildings. The North American Industry Classification System (NAICS) code for this procurement 236220 Commercial and Institutional Building Construction, and the business size standard is $45.0 Million. The magnitude of construction for this project is Between $500,000 and $1,000,000 per FAR 36.204. The full Solicitation, Specifications, Drawings and related documents will be posted on Contract Opportunities on or about October 30, 2026, unless additional notice is given, or this notice is modified or cancelled at SAM.gov. The response submittal address, date and time will be included in the solicitation. This procurement is 100% Set-Aside for Service-Disabled Veteran Owned Small Business (SDVOSB) concerns. Only verified SDVOSB firms are eligible to submit an offer or receive an award of a VA contract that is set-aside for SDVOSB in accordance with VAAR Part 819. A non-verified vendor that submits a bid or proposal will be rejected as non-responsive. Offers received from concerns that are not Service-Disabled Veteran-Owned Small Business (SDVOSB) concerns shall not be considered. (See VAAR Clause 852.219-10 VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside.) To be eligible for award, the SDVOSB must be considered small under the relevant NAICS code and must be registered and verified in the following websites: those desiring to receive an award from this solicitation must be registered at https://search.certifications.sba.gov/. Companies must have the Certified Veteran Enterprise (CVE) seal on their registration to be considered for an award. The SBA database https://search.certifications.sba.gov/ will be checked both upon receipt of an offer and prior to award; firms must be currently registered in the System for Award Management (SAM) database at www.SAM.gov and have completed online Representations and Certifications prior to contract award. In accordance with VAAR 819.7003(b), at the time of submission of bids, and prior to award of any contracts, the offeror must represent to the Contracting Officer that it is (1) SDVOSB eligible under VAAR Subpart 819.70; (2) Small business concern under the NAICS code assigned to this acquisition; and (3) SDVOSB listed as verified in SBA database at https://search.certifications.sba.gov/. Interested bidders will be required to furnish a Bid Bond; and the awarded Contractor will be required to provide Performance and Payment Bonds if needed. This presolicitation notice is not an invitation to submit a bid. The Contracting Officer and point of contact for this solicitation is Richard Adu at Richard.Adu@va.gov. Telephone requests will NOT be accepted. -End of Document-
76%
Pre-Solicitation10/20/2026
Contractor shall furnish all labor, materials, tools and equipment required for the following infrastructure improvements: electrical, bonding, UPS, building management system interfaces, access security, assess for new and upgrades to existing HVAC, reconfiguration, expansion and renovation of existing space in buildings as necessary, data center/main server room systems and infrastructure physical security upgrades, install diversified path to data center for wan, access and upgrade fiber infrastructure backbone campus wide within buildings and between buildings, hazardous materials abatement at the St. Cloud Veterans Affairs Health Care System (VAHCS). All work completed in accordance with the specifications and contract drawings.
74%
Solicitation08/16/2022
73%
Sole Source / J&AOpen

Additional Details

Solicitation Number

36C78622B0009

Archive Date

Aug 7, 2022

Office Address

QUANTICO, VA, 22134