GovChime
Notice ID: f6a2246921be4d2395e90d1256fa2b4eAward NoticeAwardedArchived

6515--B&S Holdings of Somerset, Inc. dba Secure Mount 36F79726D0126 Award - 05/15/2026-05/14/2031

Awarded on May 15, 2026. The description is published on SAM.gov: Full description on SAM.gov.

Awarded tounder 36F79726D0126 (source: SAM.gov award notice)• $500.0K

Overview

Posted
May 1, 2026
Notice type
Award Notice
NAICS
339112: Surgical and Medical Instrument Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
NAC FEDERAL SUPPLY SCHEDULE (36F797)
Last updated
Oct 31, 2026
First published
Last updated on SAM.gov
Award date
May 15, 2026
Award amount (SAM.gov award notice)
$500.0K

Identifiers

Solicitation number
36F79726D0126
Notice ID
f6a2246921be4d2395e90d1256fa2b4e
Award number (PIID)
36F79726D0126

Description

No description in the SAM.gov data feed for this notice.

Full description on SAM.gov

Award Overview

Award Number

36F79726D0126

Award Amount (SAM.gov award notice)

$500.0K

Award Date

May 15, 2026

Awardee

Awardee UEI

T6HQSGMC5TS3

Awardee CAGE Code

0KQG8

Awardee Address

JACKSON, MI 49202, MI

Line Item Number

36

Original Solicitation

Notice ID: f6a2246921be4d2395e90d1256fa2b4e

Posted Date: May 1, 2026

Original Response Deadline: Not specified

Contacts

Contracting Officer

Primary Contact

FSS Help Desk
VA Federal Supply Schedule (FSS) Service

Documents

Files (1)

  • 36F79726D0126.docx

    13 KBAdded in Award Notice version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Award NoticeArchivedCurrent

    6515--B&S Holdings of Somerset, Inc. dba Secure Mount 36F79726D0126 Award - 05/15/2026-05/14/2031

    Notice f6a2246921be4d2395e90d1256fa2b4e on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
73%
Combined Synopsis12/31/2026
THIS IS A SOURCES SOUGHT FOR MARKET RESEARCH PURPOSES ONLY to determine the availability of potential Service-Disabled Veteran-Owned Small Businesses (SDVOSB) or Veteran-Owned Small Businesses (VOSB), Women Owned Small Businesses (WOSB) or any other small business firms for a small business category type set-aside. The Department of Veterans Affairs, Network Contracting Office (NCO) 8, is conducting market research to determine potential qualified sources capable of providing Thompson Surgical Reusable Instruments ( Brand Name or Equal) for Bay Pines VA Healthcare System. OVERVIEW: SEE ATTACHED DRAFT STATEMENT OF NEED. Please include the following information about your organization in your response: Company Name, Address, Size Standard, UEI#, Cage Code Capabilities Statement - including whether all items are on existing government contract Contract number (If applicable) Place of Manufacturing Point of Contact name, phone number, and email address Authorized distributorship letter from the manufacturer (If a distributor) Will the prime contractor provide products it manufactures? Will the prime contractor acquire the products from a small or large business manufacturer? *If it is a nonmanufacturer, is it providing the end items of a small business manufacturer? What percentage of the total contract value will be subcontracted? All questions shall be submitted in writing to Maia.rylandlesesene@va.gov and Cindy.Smith@va.gov Organizations responding to this RFI should provide the company s capabilities to perform this requirement. The North American Industry Classification System (NAICS) code is 339112 and the small business size standard is 1,000 Employees. The information received as a result of this notice will be considered solely for the purpose of determining whether to conduct a competitive procurement. A determination by the VA not to open the requirement to open competition, based on responses to this sources sought synopsis is solely within the discretion of the VA. The Government does not intend to pay for any information provided under this sources sought synopsis. The Capabilities Statement for this sources sought is not expected to be a Proposal, nor does it restrict the Government to an ultimate acquisition approach, but rather short statements regarding the company s ability to demonstrate experience in relation to the areas specified herein. All information received in response to this sources sought notice will be marked as proprietary and will be handled accordingly. This synopsis is for information and purposes only and is neither to be construed as a commitment by the Government. Respondents will NOT be notified of the results of the evaluation. **NOTE: Dept. of Veterans Affairs has the right to set aside for SDVOSBs/VOSBs if two or more responses are received with the required information listed above, by the due date specified below. All responses to this sources sought notice must be sent via email to Maia.rylandlesesene@va.gov and Cindy.Smith@va.gov no later than 1:00PM Eastern Standard Time on November 18, 2026, as specified above.
68%
Market Research11/18/2026
Revision: 01 Effective Date: 11/15/2024 Acquisition ID#36C252-27-AP-0957 Page 1 of 2 Please note that this is not a request for proposal nor a request for quote as there is no solicitation document available. Therefore, this is a notice of intent issued by the Department of Veterans Affairs to negotiate a limited source contract with Iramed Corporation. DEPARTMENT OF VETERANS AFFAIRS Justification for Single Source Awards RFO FAR 12.102 For Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K) Acquisition Plan Action ID: 36C252-27-AP-0957 Contracting Activity US Department of Veterans Affairs Great Lakes Acquisition Center (GLAC) VISN 12 115 S. 84th Street Milwaukee, WI 53214 2237: 556-27-1-2993-0011 Brief Description of Supplies/ Services required and the intended use/Estimated Amount: The Captain James A. Lovell Federal Healthcare Center (FHCC), Building 556, Nursing Services, is requesting the acquisition of one MRI-compatible IV infusion pump system for the Intensive Care Unit (ICU). MRI-compatible infusion pumps are medically necessary for ICU patients who require continuous vasoactive or sedative titratable infusions while undergoing magnetic resonance imaging (MRI) to support the diagnosis and evaluation of complex disease processes. Estimated Amount: $105,270.20 Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used: The availability of this equipment will enable FHCC to perform medically necessary MRI examinations on-site, reducing the need to transfer patients to outside facilities. Currently, these patients are often taken for CT scans; however, CT imaging may not provide the comprehensive diagnostic information required for certain conditions Standardization and compatibility with the MRI IV infusion equipment currently installed at the facility are essential requirements for this acquisition. The requested system is intended to integrate with the existing equipment and support established clinical workflows, training, maintenance, and operational procedures. Substituting products from another manufacturer could result in incompatibility, require additional accessories or system modifications, necessitate staff retraining, and increase costs to the facility. Therefore, procurement of the compatible MRI IV Infusion Pump System is justified to maintain system continuity, operational efficiency, and patient-care capabilities. Description of market research conducted and results or statement why it was not conducted: Market Research Findings: An SBA.gov search under NAICS code 339112 identified zero (5) SDVOSBs and (13) VOSBs. Two additional searches were conducted on sba.gov by combining NAICS code 339112 with the keywords Quad Non-Magnetic IV Pump System and Non-Magnetic IV Pump System and applying specific filters for SDVOSBs and VOSBs. Both searches yielded zero (0) results. A search on GSA Advantage using the keywords Non-Magnetic IV Pump System produced several results that does not appear to meet the requirement. The Contracting Officer (CO) searched Google.com using the keywords Non-Magnetic IV Pump System and identified several vendors, including BD, BioSpace, Hospital & Healthcare management, Iradimed, InMed, MDPI, and Ivenix. Although several alternative vendors were identified, their products are not compatible with the MRI IV infusion equipment currently installed at the facility. Standardization and compatibility are essential requirements for this acquisition. The requested system is designed to integrate with the existing equipment and support established clinical workflows, training, maintenance, and operational procedures. Substituting products from another manufacturer could lead to compatibility issues, require additional accessories or system modifications, necessitate staff retraining, and increase facility costs. Therefore, procuring the compatible MRI IV infusion pump system is justified to ensure system continuity, operational efficiency, and uninterrupted patient-care capabilities. CO received a letter of authorization from the vendor that certifies Iradimed Corporation is the sole manufacturer and authorized seller of the MRidium 3870 MRI Infusion System and its accessories. Due to proprietary considerations, Iradimed Corporation is also the exclusive source for replacement parts for the MRidium MRI Infusion Pump System. The MRidium 3870 MRI Infusion System is the only nonmagnetic, MRI-compatible IV infusion pump currently available on the market. Contracting Officer's Certification: Purchase is approved in accordance with RFO FAR 12.102. I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief. Vernise L. Newton Contracting Officer
68%
Special Notice11/17/2026
This market research notice is being conducted by Network Contracting Office (NCO) 17 VHA Regional Procurement Office-West (RPOW) 5441 Babcock Road Medical Center, 302 San Antonio TX 78240 for the procurement for the Multilab Series II Roorda Vascular System W/DICOM, integration capabilities for San Antoino Veterans Health Care System VA, TX 78229 Background and Requirement: San Antiona Veteran Healthcare System, 7400 Merton Minter, San Antonio, Tx 78229 is seeking a Multilabel Series II Roodra Vascular System W/DICOM. The purpose of this procurement is to acquire, deliver, install, test, and deploy four (4) Multilabel Series II Roodra Vascular Systems with DICOM integration capabilities. The required system is the Unetix Multilab II Roorda with DICOM functionality. The objective of this procurement is to provide the surgical service with advanced vascular diagnostic equipment that seamlessly integrated with existing imaging and clinical information systems through DICOM connectivity for their vascular clinic. The Unetix Multiab II Roorda is the only known vascular diagnostic system that is fully compactable with the facility s VascuPro network and reporting platform. Procuring this equipment will ensure continuity of operations, maintain interoperability with current infrastructure, and support efficient delivery of patient care without the need for costly system modification or workflow disruptions at 7400 Merton Minter, San Antonio, Tx 78229. If this is an item your business can provide, please respond to this Sources Sought Notice by 11:00 AM Central Time on Thursday, 19 November 2026. The intent of this notice is to establish sources to define the procurement strategy (e.g. set-aside, sole source, unrestricted) for a solicitation that VA intends to post soon. Interested contractors are requested to respond in accordance with the following: a. where is the item manufactured, the VA is interested in procuring items manufactured in the United States. If you have an existing GSA or VA, Federal Supply Schedule contract, include the contract details in your response. Please note that VA is particularly interested in determining the availability of Service Disable Veteran Owned Small Business/Veteran Owned Small Business or other Small Business manufacturers or authorized distributors that can provide this item. Respond to this notice if you can provide these products listed in the table in the background and requirement section above. In response, please cite your business size status. DISTRIBUTORS: You must provide proof that you are an authorized distributor. VA does not accept gray market items. Vendors are requested to submit estimated market research pricing with their responses. The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g. if CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside). Responses should include: (1) Business Name (2) Business Address (3) Point of Contact - Name - Phone Number - E-mail Address (4) SAM UID Number (5) NAICS code (6) Business Size: SMALL or LARGE (7) Type of Business: SERVICE-DISABLED VETERAN OWNED (SDVOSB), VETERAN OWNED(VOSB), 8A, HUBZone, WOMAN-OWNED (WOSB), etc. (8) Letter stating OEM authorized dealer, authorized distributor, or authorized reseller for the proposed equipment and/or services if applicable (9) GSA/FSS Contract Number if applicable All businesses eligible to provide this item are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement. Send responses to Michelle Cunningham at michelle.cunningham@va.gov. DISCLAIMER: THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, Contractors may submit a capability statement, proposal, or quotation which shall be considered by the contracting officer whether to continue with the sole source procurement or to provide for competition. Due to technical issues, please allow additional time if you re using electronic means. Responses received will be evaluated; however, a determination by the Government not to compete the proposed procurement based upon responses received to this notice is solely within the discretion of the Government.
68%
Market Research11/19/2026
Good day, SDVOSB s, VOSB s & SB's Sources Sought INTENT TO SOLE SOURCE Pre-Solicitation. This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SDVOSBs VOSBs , or SBs . This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if none or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete. Please reply in the affirmative via email if you are interested and can provide the required product/services for this requirement. Please provide your capability statement, and any other supportive documentation. I will accept responses for this Sources Sought until the 16th of November 2026 14:00 EDT, thanks. 1. General: C.W. Bill Young Veterans Medical Center Surgery Service located at 10000 Bay Pines Blvd. Bay Pines, Fl. 33744 is seeking procurement of six transducers and six trays from GE Healthcare. The department requires replacement of ultrasound transducers that have reached the end of their operational life and can no longer be repaired or supported by the manufacturer. 2. Background: These transducers are vital to patient diagnostic and procedural imaging. The existing probes have been evaluated by Biomedical Engineering and determined to be non-functional, unrepairable, and beyond economical repair. Without replacements, the service cannot maintain adequate imaging capacity to support patient care. 2.Scope of Work: This requirement needs to provide six (P/N: 9018) E14C4T Triplane endo transducers and six (P/N:UA2511) trays. 3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 36 for Equipment. 4.Period of Performance: The product is requested to be delivered no later than December 19th. 5.Type of Contract: Supply: Firm, Fixed Price. 6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below. 6.1 Salient Characteristics NAME BRAND - Equipment Requirement: GE Healthcare QTY. 6 - (P/N: 9018) E14C4T Triplane Endo Transducer QTY. 6 (P/N: UA2511) Reprocessing Trays for E14C4T Equipment Requirement: Minimum Required Features and Specifications Type / Intended Use: Must be a transrectal ultrasound transducer specifically designed for prostate imaging and biopsy guidance in urology applications. Must provide multi-plane (triplane) imaging capability allowing visualization of transverse, sagittal, and end-fire planes without changing probes. Frequency & Imaging Performance: Must operate within a frequency range of approximately 4 MHz to 14 MHz to provide both high-resolution and deep-penetration imaging of the prostate. Must support B-mode, M-mode, Color Doppler, and Power Doppler imaging modes (with optional elastography and contrast imaging if supported by the connected ultrasound system). Biopsy and Procedural Capability: Must include or support an integrated biopsy guide channel that allows both biplane and end-fire biopsy procedures without requiring probe exchange. Must accommodate standard 17- or 18-gauge biopsy needles through compatible biopsy guide attachments. Must permit real-time needle visualization during transrectal or transperineal prostate biopsy procedures. 4. Design & Ergonomics Must be a compact, endocavity-style probe suitable for patient comfort and operator ergonomics during transrectal use. Must include a control ( Smart ) button or equivalent for hands-free freezing, storing, or switching imaging planes directly from the probe handle. Must be designed for one-handed operation and compatible with sterile probe covers. 5. Compatibility Must be fully compatible with BK Medical ultrasound systems, including bk3000, bk5000, bkActiv, and bkSpecto platforms. Must connect using the appropriate BK Medical proprietary connector interface without the need for modification or adapters. 6. Cleaning & Sterilization Must be fully immersible and validated for standard high-level disinfection or sterilization processes used for endocavity probes. Must be compatible with approved sterile covers and disinfection solutions specified in the manufacturer s reprocessing guide. 7. Construction & Safety Must be constructed of biocompatible materials suitable for internal use (per ISO 10993 or equivalent standards). Must comply with applicable IEC/EN 60601-1 electrical safety and ultrasound acoustic output limits. Must be supplied new, manufacturer-certified, and covered under OEM warranty for clinical use. Summary Table Feature Category Requirement Type Triplane transrectal prostate ultrasound transducer Frequency 4 14 MHz Imaging Modes B, M, Color Doppler, Power Doppler (Elastography optional) Biopsy Capability Integrated dual-plane biopsy guide Needle Compatibility 17 18 G Operation One-handed, Smart Button on probe Sterilization Fully immersible, high-level disinfectable Compatibility bk3000, bk5000, bkActiv, bkSpecto Intended Use Prostate imaging and biopsy guidance Condition New OEM product, OEM warranty
68%
Market Research11/16/2026

Additional Details

Solicitation Number

36F79726D0126

Archive Date

Jun 30, 2026

Office Address

HINES, IL, 60141