GovChime
Notice ID: 4c1db05c67e6479c8a0f731fae6be06bCombined Synopsis/Solicitation

W--U.S. EPA - Water Filler Stations for DC

Archived on September 29, 2020. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
Posted
September 11, 2020
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
532420: Office Machinery and Equipment Rental and Leasing
Agency
Environmental Protection Agency

Notice details

Office
CINCINNATI ACQUISITION DIV (CAD)
PSC
W: LEASE/RENT EQUIPMENT
Last updated
Apr 29, 2026

Identifiers

Solicitation number
68HERC20Q0120
Notice ID
4c1db05c67e6479c8a0f731fae6be06b

Description

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; a quotation is being requested and a written solicitation will not be issued. The U.S. Environmental Protection Agency (EPA), Office of Mission Support (OMS) in Washington, D.C. requires a contractor to install, repair, replace, inspect and maintain freestanding and countertop water bottle fillers to provide cold and hot water supplied with tap water and associated filtration in approximately 90 pantries throughout EPA Headquarters buildings. All necessary components, materials and services for a freestanding or countertop water bottle filler shall be included with the following salient characteristics to meet the minimum requirements: This item description (further detailed in the attached Statement of Work and Filler Station Inventory) establishes the minimum requirements for the lease, installation and maintenance of the water bottle fillers. Utilizing this system, the EPA will be able to reduce the use of single-serving plastic water bottles and cut greenhouse gas emissions from water transportation and delivery. All necessary components and materials for a complete freestanding or countertop water bottle filler shall be included with the following salient characteristics to meet the minimum requirement: Unit Specification: Water bottle fillers will be either countertop or freestanding models and must meet the following performance requirements: - Deliver cold and hot water on demand - ENERGY STAR qualified - Equipped with filtration to remove: - Aesthetic chlorine - Particulate Class I (particle size 0.5 (1 micron) - Lead - Tested and certified in accordance with NSF/ANSI 42 and 53 - All units installed must be new - Contractor is responsible for all costs associated with the removal of units at the end of the contract's life, if required Installation Requirements: The contractor shall install freestanding or countertop water bottle fillers in each pantry. The contractor shall provide all necessary personnel, equipment, supplies, products and permits required for this project. All equipment and products supplied by the contractor shall be installed in accordance with the manufacturer's recommendations and applicable codes. The contractor shall be responsible for obtaining all necessary permits, licenses and/or inspections if required. The contractor shall comply with all local, state, and federal regulations. The contractor shall perform all work Monday through Friday, between the hours of 7:00 a.m. to 11:30 a.m. or 1:30 p.m. to 4:30 p.m., unless otherwise specified by the Project Officer (PO). Security escorts will be required for the installation period and during routine maintenance, repairs and replacements if the tech does not have a vetted EPA ID card. Personnel recommended by the contractor to work onsite must have favorable fingerprints, performed and confirmed by the EPA security office. Work must be scheduled and coordinated with the PO or a Facility Manager designated by the PO in advance to prevent the interruption of other ongoing work. No advertising or other signage is permitted onsite during or upon completion of this work without the permission of the EPA. The contractor shall provide an installation plan and a list of materials to be used prior to commencing work, including all plumbing value specifications. This includes a schematic of the intended plumbing approach, including intended materials, for approval by the EPA prior to installation. Materials shall include all necessary new equipment, hardware, pipe, tubing, plumbing fittings, electrical connections, and miscellaneous parts. All materials used shall be submitted to the EPA for review and approval. The contractor shall drill holes through the countertop or under the sink cabinet (laminate) to connect the water lines from the water source to the water filler/water coolers. All plumbing work, including installation of any water supply lines, must be completed by a Licensed Green Plumber (www.greenplumbersusa.com). All plumbing shall be permanently affixed to existing plumbing and include an isolation valve. The contractor shall not clamp on piercing saddle valves to existing pipe. The contractor shall be responsible for cleanup and repair of any damage to the EPA facility or equipment which results from project installation, repair, replacement and maintenance. The contractor shall remove and dispose of all installation and construction debris. The contractor shall not dispose debris or trash on the EPA property. All damage by the contractor to EPA's property shall be repaired within 24 hours after confirmation by the EPA. All materials used must be approved by the EPA Safety and Health Division, prior to commencement of repair work. Maintenance Requirements: All equipment and products supplied by the contractor shall be maintained in accordance with the manufacturer's recommendations and applicable codes. The contractor shall demonstrate to the EPA representatives designated by the PO how to use the water filler units. The contractor shall provide one complete copy of all manufacturer's operating and maintenance instructions to the PO upon completion of the project. The contractor shall provide the PO and any named alternate with a semi-annual maintenance schedule of services performed, maintenance type, building, pantry location, date services performed, filter replacement, etc. The contractor shall assume that approximately 50-75 employees will be using each of these units on a daily basis. The contractor shall replace the filters in all water bottle fillers every six (6) months. The contractor shall replace the filters in all or some water bottle fillers as needed for special/unique occurrences in rare occasions. Maintenance personnel shall provide schedules with enough notice to obtain the necessary escorts to enter EPA's facilities during normal business hours and visibly place a damage free removable sticker or other approved signage on units indicating filters have been changed (mm/dd/yy) and when the next filter change is scheduled (mm/dd/yy). The contractor shall respond to maintenance calls within 24 hours after receiving a telephone call or an email from the PO, Alternate PO or Facility Manager. The contractor shall provide a new comparable replacement unit within 24 hours after the PO's approval of the unit. There will be no charge to the EPA to remove units no longer required. Monthly Reports: The contractor shall submit monthly reports to the PO and any named Alternate which shall include the following information, but not limited to: - Date serviced - Problems detected - Date filter replaced - Building, floor and pantry number - Date repaired and/or replaced - Any impediments encountered - Current number of units onsite - Current active POCs and Techs (name, phone, and email) Partial orders will not be accepted. Offeror's must quote all requested items. Anticipated Period of Performance: Base Period 10/1/2020 - 9/30/2021 Option Period 1 10/1/2021 - 9/30/2022 Option Period 2 10/1/2022 - 9/30/2023 Option Period 3 10/1/2023 - 9/30/2024 Option Period 4 10/1/2024 - 9/30/2025 Any delivery shall be FOB Destination. Delivery shall be made to the addresses listed in the Statement of Work. This acquisition is a total small business set aside and will be processed in accordance with FAR Parts 12 and 13. The North American Industry Classification System (NAICS) code is 532420 with a small business size standard of $35M. The solicitation number is 68HERC20Q0120 and is issued as a request for quotation. All attachments are available through the FedConnect link included within this Federal Business Opportunities posting. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2020-08, effective 13 August 2020. This solicitation includes the following clauses and provisions: Clauses: 52.204-25 Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment; 52.212-4 Contract Terms and Conditions; and 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders; Provisions: 52.204-24 Representation Regarding Certain Telecommunications and Video Surveillance Services or Equipment; 52.212-1 Instructions to Offerors; 52.212-2 Evaluation - Commercial Items; 52.212-3 Offeror Representations and Certifications-Commercial Items; 52.225-25 Prohibition On Contracting With Entities Engaging In Sanctioned Activities Relating To Iran-Representation And Certifications; For 52.212-5 the following clauses apply within: 52.204-10 Reporting Executive Compensation and First-Tier Subcontractor Awards; 52.209-6 Protecting the Government's Interest when Subcontracting with Contractors Debarred, Suspended, or Proposed for Debarment; 52.219-6 Notice of Total Small Business Set-Aside; 52.219-28 Post-Award Small Business Program Rerepresentation; 52.222-3 Convict Labor; 52.222-19 Child Labor Cooperation with Authorities and Remedies; 52.222-21 Prohibition of Segregated Facilities; 52.222-26 Equal Opportunity; 52.222-35 Equal Opportunity for Veterans; 52.222-36 Equal Opportunity for Workers with Disabilities; 52.222-37 Employment Reports on Veterans; 52.222-50 Combating Trafficking in Persons; 52.223-18 Encouraging Contractor Policies to Ban Text Messaging while Driving; 52.225-5 Trade Agreements; 52.225-13 Restrictions on Certain Foreign Purchases and 52.232-33 Payment by Electronic Funds Transfer - System for Award Management. Award will be selected based on the Lowest-Priced, Technically Acceptable offer that meets all requirements of the Statement of Work. Offerors must itemize their total proposed price showing a monthly per unit price for each period of the contract. Quotations shall be submitted no later than September 10, 2020 by 3:00 pm Eastern Time (ET) via FedConnect.net. Emailed quotes will not be accepted. Interested offerors may submit questions to the Contracting Officer until 12:00pm ET on September 4, 2020. Quotations shall include all necessary documentation for the EPA to verify technical acceptability of the proposed equipment/services to meet the minimum specifications. The EPA anticipates awarding without discussions. All responsible sources may submit a quotation, which shall be considered by the agency. The point of contact for this requirement is Brad Werwick, Contracting Officer, at 513-487-2018 or email at Werwick.Brad@epa.gov.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:68HERC20Q0120
  1. Combined Synopsis
  1. 3×
    Combined SynopsisCurrentSep 2, 2020

    W--U.S. EPA - Water Filler Stations for DC

    Notice 4c1db05c67e6479c8a0f731fae6be06b on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
UPDATED 20 OCT 2026 - RFQ AMENDMENT #3 to update Attachment #3, HOTEL ATTESTATION 1. Verbiage change made for info regarding hotel fees, timelines, and loading information (highlighted in Document). 2. 26Q0012_Attch 3_Hotel Attestation is hereby amended to 26Q0012_Attch 3_Hotel Attestation_AMMENDMENT1 3. No other documents, terms, or conditions of this RFQ are revised or changed as a result of this amendment. - - - - - UPDATED 8 OCT 2026 - RFQ AMENDMENT #2 to update Attachment #5, Q&A Government Responses/ Request for Quotation (RFQ) 1. FORMAL RFQ for "FY27 Nursing Practice Oversight Course" is hereby amended to update Attachment #5, Q&A Spreadsheet (file "26Q0012_Attch 5_Q.A GOVERNMENT_Responses_5 Oct 26”) with Government responses to quoter questions received through COB 8 Oct 26. This RFQ will be updated as additional questions are submitted. 2. Request for Quotation (RFQ) (“26Q0012_0_RFQ_25 SEP 26”) is hereby amended to 26Q0012_0_RFQ_AMENDMENT 2_08 OCT 26.docx updating the NAICS CODE in section 1.1 to reflect 532490. 3. No other documents, terms, or conditions of this RFQ are revised or changed as a result of this amendment. - - - - - UPDATED 5 OCT 2026 - RFQ AMENDMENT #1 to update Attachment #5, Q&A Government Responses 1. FORMAL RFQ for "FY27 Nursing Practice Oversight Course" is hereby amended to update Attachment #5, Q&A Spreadsheet (file "26Q0012_Attch 5_Q.A GOVERNMENT_Responses_5 Oct 26”) with Government responses to quoter questions received through COB 2 Oct 26. This RFQ will be updated as additional questions are submitted. 2. No other documents, terms, or conditions of this RFQ are revised or changed as a result of this amendment. - - - - - ORIGINAL POSTING: 28 SEP 2026 – COMBINED SYNOPSIS/SOLICITATION 1. FORMAL RFQ for "FY27 Nursing Practice Oversight Course" releases the following attached documents: Request for Quotation (RFQ) (“26Q0012_0_RFQ_25 SEP 26”) Statement of Work (SOW) (“26Q0012_Attch 1_SOW_14 Sep 26”) Clauses & Provisions (CLS) ("26Q0012_Attch 2_Clauses") Hotel Attestation Form (“26Q0012_Attch 3_Hotel Attestation”) Pricing Schedule (“26Q0012_Attch 4_Pricing Schedule”) Q&A Spreadsheet ("26Q0012_Attch 5_Q.A Spreadsheet") Wage Determination (“26Q0010_Attch 6_DOL WD”)
-Combined Synopsis11/16/2026
Notice of Award for DoW Maintenance Symposium Exhibit Furnishings and Electrical Services Award Date: 5 Nov 2026 Contract Award Number: FA857927P0011 Contractor Awarded CAGE: 6V438 Contractor Awarded Name: SHEPARD EXPOSITION SERVICES INC Total Contract Value: $21,754.80
-AwardedOpen
This action is a single-source, firm-fixed-price purchase order to be awarded to Shepard Exposition Services, Inc., 1778 Marietta Blvd NW, Atlanta, GA 30318-3661, for rental exhibit furnishings and electrical services supporting the Headquarters Air Force (HAF) 20-foot by 40-foot booth assigned to AFSC A3/4 at the Department of War (DoW) Maintenance Symposium in Fort Lauderdale, Florida. This procurement will be conducted using simplified acquisition procedures under Federal Acquisition Regulation (FAR) Part 13. The authority permitting restriction of competition is FAR 13.106-1(b)(1), which allows solicitation from one source when the contracting officer determines only one source is reasonably available to satisfy the Government’s requirement. acquisition.gov. Restricting competition to Shepard Exposition Services, Inc. is in the best interest of the Government based on the following event-specific operational factors: Event-designated decorator, Exhibit-hall access and installation coordination, Event-controlled electrical service, Avoidance of performance and schedule risk, Time-sensitive pricing.
-Solicitation11/05/2026
DESCRIPTION The Cincinnati Veterans Administration Medical Center (VAMC) has a requirement to provide Temporary Bulk Oxygen Rental & Support Services for Medical Gas Line Repair. The intention of this Sources Sought is to obtain information only. Please do not send a proposal. Requested information: To aid acquisition planning, we re seeking capable and interested firms for the information requested. If your firm meets the criteria please send the point of contract (ronald.heidemann@va.gov) the following, via email: Firm s Name Socio-Economic Status Whether or not your company has a contract vehicle we can order against If your company believes there is an alternative NAICS code please provide this If your company has any questions please provide. 1. Contract Title. Temporary Bulk Oxygen Rental & Support Services for Medical Gas Line Repair 2. Background. Provide a turnkey temporary bulk oxygen supply and services (rental tank, transport, installation, line hookup, controlled shutdown/bleeding, monitoring, and removal) to maintain uninterrupted oxygen service while VA performs a pin hole leak repair in the hospital s piped oxygen system. Work shall comply with VHA Directive 7515(1) and NFPA 99 Health Care Facilities Code requirements for medical gas systems 3. Scope: The Contractor shall furnish all rental equipment, labor, materials, transport, and qualified personnel to: Deliver and set a temporary bulk liquid oxygen (LOX) tank with vaporizers and regulators sized for hospital demand. Connect the temporary supply to the hospital oxygen pipeline (via EOSC/auxiliary connection or source valve), including gauges, check valves, and isolation devices; verify pressure, purity, and flow stability per NFPA 99 Chapter 5. Coordinate and execute a controlled shutdown and bleeding of affected lines, isolate zone valves, and validate alarm behavior with VA Clinical Engineering and Respiratory Therapy. Monitor supply, pressure, and alarms throughout the outage; maintain contingency oxygen cylinders for clinical areas at risk. Support VA repair team during line replacement/brazing and re-qualification (e.g., leak tests, purity checks, pressure verification), then transition back to the permanent bulk system and remove temporary equipment. 4. Specific Tasks : Temporary LOX tank with vaporizers sized to meet peak hourly demand; provide pressure regulating, relief, and check devices; all oxygen service compatible, oil free. Auxiliary/EOSC connection hardware, hoses, and valves compliant with facility EOSC design; include filtration as required. (NFPA 99 2024 emphasizes auxiliary connections for emergency preparedness.) Alarm interface: ensure master and area alarms receive accurate signals during temporary supply (low pressure, source changeover). Performance. Delivery requirements are met: Following VA repair and verification, transition back to primary bulk supply; execute valve re opening sequence, purge procedures, re pressurization, and alarm validation; document test results. Remove temporary equipment and restore site; submit as left drawings, pressure logs, and certification reports if applicable. 6. Place of Performance. Cincinnati VAMC, 3200 Vine Steet, Cincinnati, Ohio 45220 7. Delivery: Cincinnati VAMC 3200 Vine Street Cincinnati Ohio 45220
-Market Research11/12/2026
Request for Quote: Procurement of Commercial Off the Shelf (COTS) Electronic Workpaper Solution for the the Office of Inspector General (OIG).
-Solicitation11/09/2026

Additional Details

Solicitation Number

68HERC20Q0120

Archive Date

Sep 29, 2020

Office Address

CINCINNATI, OH, 45268