Notice ID: bfcda9a00feb43b4b20b1779581b5242Combined Synopsis/Solicitation
Remove and replace existing R-22 Freon using Air Condition (AC) units
Archived on August 19, 2021. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 2:00 PM UTC−04:00
- Posted
- July 26, 2021
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of Homeland SecurityUS IMMIGRATION AND CUSTOMS ENFORCEMENT
Notice details
- Office
- MISSION SUPPORT WASHINGTON
- Place of performance
- Florence, AZ, 85132
- PSC
- 4120: AIR CONDITIONING EQUIPMENT
- Last updated
- Dec 4, 2025
Identifiers
- Solicitation number
- 70CMSW21Q00000017
- Notice ID
- bfcda9a00feb43b4b20b1779581b5242
Description
Remove and replace Jail Units - (4ea) 7.5-ton, (2ea) 4-ton, and (2ea) 5-ton package gas electric units and adapter curbs. Remove and replace Pod Units A,B,C,D,E (10ea) 7.5-ton package gas electric 2 stage high efficiency units and adapter curbs. The Jail units 3 & 4 need to be re-configured to avoid intake and discharge of air into each other. Relocate and replace the jail POD disconnects to the outside of the surrounding wall and replace all other disconnects. Remove and replace 28 AC units and air handling units . The units range from 3-12.5 ton, an inventory list will be provided upon request. Crane up new units with new adapter curbs for all roof mounted units. Verify ground units accessibility and provide quotes accordingly. Install new A/C whips to each unit. Install new gas flex to each unit where applicable. Check conduit for good condition and reuse. Replace if necessary. Install energy management controllers with discharge air sensors, fan/compressor stats, tie into existing system to Building Management Systems, install Wi-Fi routers and hard wire units on roof with new space temp stainless steel plates. The existing BMS is Niagra by Tritium Bacnet to interface. The final integration of this system must be coordinated by onsite ICE staff and local servicing contractor. Contractor shall pass along any applicable manufacturer and installer warranty to the Government .
Award Overview
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
70CMSW21Q00000017- Combined Synopsis
- Combined SynopsisCurrentJul 26, 2021
Remove and replace existing R-22 Freon using Air Condition (AC) units
Similar Opportunities
Additional Details
Solicitation Number
70CMSW21Q00000017
Archive Date
Aug 19, 2021
Office Address
WASHINGTON, DC, 20024