Notice ID: 2227a107b489437495e1eff5b2486cb2Solicitation
Provide Material for Seven New Manholes, Handhole, Conduits from building 91 to 252 at Glynco, GA
Archived on August 19, 2021. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 4:30 PM UTC−04:00
- Posted
- August 10, 2021
- Notice type
- Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 238210: Electrical Contractors and Other Wiring Installation Contractors
- Agency
- Department of Homeland SecurityFEDERAL LAW ENFORCEMENT TRAINING CENTER
Notice details
- Office
- FLETC GLYNCO PROCUREMENT OFFICE
- Place of performance
- Brunswick, GA, 31524
- Last updated
- Dec 4, 2025
Identifiers
- Solicitation number
- 70LGLY21QSSB00082
- Notice ID
- 2227a107b489437495e1eff5b2486cb2
Description
Provide Material for seven new manholes. handholes, conduits in accordance with the attached RFQ.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
70LGLY21QSSB00082- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- SolicitationCurrentAug 10, 2021
Provide Material for Seven New Manholes, Handhole, Conduits from building 91 to 252 at Glynco, GA
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
The U.S. Coast Guard Academy requires a qualified, licensed electrical contractor to inspect, repair as necessary, test, and restore Eaton/Cutler-Hammer MVS2 13.2 kV medium-voltage load interrupter switchgear, with primary work focused on Cabinet 5 and the associated 15 kV feeder cable serving Smith Hall. The contractor shall inspect Cabinet 5 for damage or missing/cannibalized components; remove and replace three Eaton 15CLE-250E fuses; procure and deliver three additional matching fuses for on-site spares; perform insulation-resistance testing of the feeder cable in accordance with current ANSI/NETA standards; provide certified test and field-service reports; coordinate all required outages and lockout/tagout procedures with the Government; and safely re-energize the cabinet and feeder upon successful completion of repairs and testing. All work shall comply with applicable OSHA, NFPA 70E, federal, state, and local requirements, including proper licensed personnel, arc-flash personal protective equipment, site protection, cleanup, and disposal of waste materials. | - | Combined Synopsis | 11/12/2026 |
The Peterson Space Force Base (PSFB) 21st Contracting Squadron is requesting information from vendors who provide the work outlined in Attachement 1 – PWS Smart T Power Project. The North American Industry Classification System (NAICS) code is 238210 – Electrical Contractors and Other Wiring Installation Contractors, and the small business size standard is $19 Million Dollars This sources sought is issued for the purpose of market research in accordance with RFO Part 10. PSFB, CO is requesting information for the subject part number for Market Research Purposes. | - | Market Research | 11/18/2027 |
This Sources Sought Posting is being issued in accordance with Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) Part 10, Market Research. The purpose of this posting is to gain knowledge of potential sources for this service including interested Small Business Concerns. Its sole purpose is to provide information for planning and market research only and shall not be construed as either a solicitation or obligation on the part of the Government. The Government welcomes responses from all interested parties; however, no decision or award of contract will be made based on responses from industry. The Government will not pay for the preparation of, nor the subsequent use of, information submitted in response to this Sources Sought. Respondents will not be notified of the outcome of the Government’s review of the information received. Additionally, the Government does not intend to hold discussions concerning this Sources Sought with any interested parties but reserves the right to contact vendors if additional information is required for clarifications as it pertains to the Sources Sought. The objective of this effort is to engineer, furnish & install (EF&I) a new inside plant (ISP) telecomm conduit that the 129 CS will use to support the future install of a new outside plant (OSP) fiber optic cable (FOC). The primary necessity of this effort is to ensure that an ISP telecomm conduit pathway is already in place and available for use prior to the onset of the forthcoming OSP FOC install inside Rm 21A. See attached draft Statement of Objectives for more information. The NAICS code for this requirement is 238210, Electrical Contractors and Other Wiring Installation Contractors. The Small Business Administration size standard for small businesses in this industry is $19,000,000. Instructions to Vendors All interested concerns will submit a written notice, not to exceed five (5) pages, stating the concern’s positive intention to submit a proposal as a prime contractor no later than the deadline posted with this notice. Responses to this Sources Sought should include the following information: A positive statement of intent to submit a proposal as a prime contractor, A listing of projects completed during the past five (5) years for both Government and private industry. The list should provide the type of service, dollar value, contract number, location, and point of contact. Also, please indicate whether the firm was a prime or subcontractor—if the firm was a subcontractor, please provide a point of contact with the prime contractor, A brief outline of resources, subcontractors, and key personnel that would be used to accomplish the contract, and Demonstration of the firm’s socioeconomic status (i.e., SB, 8(a), HUBZone, EDWOSB, WOSB, SDVOSB, etc.), and size. If adequate small business firms are not available for adequate competition for this project, it may be advertised as an unrestricted solicitation. Submit responses directly to austin.breault.1@us.af.mil; telephone calls and facsimile responses will not be honored. Please reference the Notice ID and project title in the subject of your message. Please limit your responses to standard documents (i.e., Microsoft Office, Adobe PDF, etc.). Do not send compressed (i.e., .zip or .exe extension) or other file types as they will be stripped from your message. | - | Market Research | 11/16/2026 |
TENKILLER 15KV SWITCHGEAR AND STATION SERVICE REPLACEMENT *PLEASE NOTE: The previous industry notices for this project are as follows: W912BV26SS04 was the Sources Sought posting for Market Research. W912BV26RA032 was the previous solicitation number posted with the Pre-Solicitation Notice. The solicitation number has been updated to W912BV27RA003. | - | Solicitation | 12/03/2026 |
The Contractor shall furnish all equipment, materials, labor, installation, integration, programming, testing, documentation, training, preventive maintenance, technical support, repair and replacement support, and other services required to upgrade, modernize, and sustain the Video Teleconferencing (VTC) and Audiovisual (A/V) system in Conference Room 203, Building 1624, Hanscom AFB, MA. All work shall be performed in accordance with Attachment 1, Statement of Work. Site Visit Registration Due: Tuesday, November 17, 2026, 3:00 PM ET Site Visit Walkthrough: Friday, November 20, 2026, 10:00 AM ET Questions Due Cut-Off: Tuesday, November 24, 2026, 3:00 PM ET Quotation Due Date: Friday, December 4, 2026, 3:00 PM ET The previous Notice ID 2026-PZI-0023 | - | Combined Synopsis | 12/04/2026 |
Additional Details
Solicitation Number
70LGLY21QSSB00082
Archive Date
Aug 19, 2021
Office Address