USCGC Penobscot Bay Water Mist Suppression System
Archived on December 20, 2025. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 8:00 AM PST
- Posted
- December 1, 2025
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 336611: Ship Building and Repairing
- Agency
- Department of Homeland SecurityUS COAST GUARD
Notice details
- Office
- SFLC PROCUREMENT BRANCH 2(00085)
- Place of performance
- Bayonne, New Jersey, 07002
- Last updated
- Nov 5, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 70Z08526Q0000870-1
- Notice ID
- 4a670ed8c4c44ec8b5dc8bb1067d457a
Description
STATEMENT OF WORK
CGC PENOBSCOT BAY OPFAC: 17507 LOCATION: Bayonne, NJ
EQUIPMENT: Hi-Fog Water Mist Fire Suppression System
COMPONENT AFFECTED: 5YR and ANNUAL INSPECTION OF SYSTEM/ Renewal of 29 Bottles and certified
MPC: R-A-13380, R-M-13373, R-C-14526
Contractor must be HI-FOG certified Technician. Contractor must set up water mist system for testing; complete the water mist system test; and place water mist system back in normal operation once test is completed. Contractor must ensure all connections, fittings, and equipment within the water mist system are operating correctly as well. Contractor shall use MPC R-A-13380, R-M-13373, R-C-14526 as guidance.
Replacement Parts to be included in 5-Year Annual Inspection:
30 - HOSE 36INCH 8MM FOR GPU (UU1168) 1 - HOSE ASSEMBLY - N2REGULATOR (A20079.1) 2 - FILTER WATER FILTER R1 1/2, 60-MICROMETER (E31048) 1 - LOW PRESSURE FRESH WATER SAFETYVALVES (M-0010165) 2 - SVM20 DNV VALVE REBUILD KITS (V14020), Jockey Pump
Any discrepancies found shall be noted; and corrected only if no other cost is needed. If any discrepancy causes cost outside the quote, this shall be routed through customer before discrepancy is corrected.
POP: 08DEC25-12DEC25
LOCATION/POC:
Ricciardi, Vincent CWO-2 USCG CGC PENOBSCOT BAY (USA) Vincent.Ricciardi@uscg.mil
Address:
CGC Penobscot Bay (WTGB-107)
85 Port Terminal Blvd. Slip 2
Bayonne NJ. 07002
252-619-6669
Award Overview
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
Files (1)
- Download
25023-Penobscot Bay-SOW FOR 5yr and ANNUAL WATER MIST INSPECTION (002).pdf
28 KBAdded in Combined Synopsis/Solicitation version 3Posted
Lifecycle
- 3Version 3Combined Synopsis/SolicitationArchivedCurrent
USCGC Penobscot Bay Water Mist Suppression System
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
70Z08526Q0000870-1
Archive Date
Dec 20, 2025
Office Address