Replace Medium Voltage Cutoff Switches PSN 16677450
Archived on January 15, 2026. Sources Sought posted by HOMELAND SECURITY, DEPARTMENT OF (US COAST GUARD) on December 1, 2025. Solicitation 70Z0G126SCCODReplaceMediumVoltageCutoffSwitches.
NAICS 238210 (Electrical Contractors and Other Wiring Installation Contractors). Place of performance: Buzzards Bay, Massachusetts. Original response deadline: . Full description on SAM.gov.
Description
SOURCES SOUGHT: THIS IS ONLY A MARKET SURVEY FOR WRITTEN INFORMATION ONLY. THIS IS NOT A SOLICITATION FOR PROPOSALS, AND NO CONTRACT WILL BE AWARDED FROM THIS ANNOUNCEMENT.
No reimbursement will be made for any costs associated with providing information in response to this announcement or any follow-up information requests. In order to protect the procurement integrity of any future procurement that may arise from this announcement, information regarding the technical point of contact will not be given and no appointments for presentations will be made.
The U.S. Coast Guard is considering whether or not to set aside an acquisition for HUBZone Small Business concerns, Service-Disabled Veteran-Owned Small Business concerns (SDVOSB), 8(a) certified Small Businessconcerns, Woman-Owned Small Business concerns or Small Business concerns, or solicit Unrestricted. The applicable North American Industry Classification System (NAICS) code is 238210, with a small business size standard of $19.0 Million. The estimated value of the procurement is between $250,000 and $500,000. Performance and Payment bonds will be required.
The U.S. Coast Guard is seeking Interested Vendors with successful past performance, current relevant experience, personnel/resources, equipment, and capability to perform the following work:
The Coast Guard requires design-build services to provide replacement of (2) 5KV distribution switches and all, incidental wiring and incidental related work. The New switches will be replaced with a new state-of-the-art system that meets current state and federal codes, design standards and industry best practices.
Contractor shall furnish all design, labor, materials, equipment, supervision, transportation and disposal necessary to provide a complete operational 5KV distribution system that meets or exceeds the National Electrical Code. Work will be completed at USCG Joint Base Cape Cod Buzzards Bay, MA.
If your Company is interested in this Requirement your response MUST include the following: (a) a positive statement of your intent to submit a proposal for this solicitation as prime contractor; (b) evidence of bonding capacity; (c) a statement identifying your certified small business designation (if any); and, (d) evidence of prior successful work similar in scope and magnitude to include contract numbers, project titles, dollar amounts, points of contact and telephone numbers. Your response is required no later than 17 December 2025. All of the above must be submitted in sufficient detail for a decision to be made on an applicable set-aside, however, limit responses to four (4) pages.
Interested Contractors should submit information via email to Christopher.L.Hunsberger2@uscg.mil with a copy to Simon.W.Leung@uscg.mil with “Sources Sought Notice 70Z0G1-26-S-Replace Medium Voltage Transformer Cutoff Switches” in the subject line.
Overview
Award Overview
Possible prior contracts
Sign in to see possible prior contracts for this requirement (matched by agency, NAICS and place of performance; not confirmed).
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
No documents available.
Lifecycle
70Z0G126SCCODReplaceMediumVoltageCutoffSwitches- Market Research
Pre-solicitation or formal solicitation typically follows within 30–180 days. (estimate)
- Market ResearchCurrentDec 1, 2025
Replace Medium Voltage Cutoff Switches PSN 16677450
Similar Opportunities
Title | Phase | Agency | NAICS | Set Aside | Posted | Deadline | Location |
|---|---|---|---|---|---|---|---|
| Awarded | 238220 | No Set-Aside | 09/24/2026 | Open | Guilford, CT | ||
Notice of Intent for Stamford Hurricane Barrier – Control Systems Replacement – Mechanical & Hydraulic Components Under the authority of RFO 6.103-1, the U.S. Army Corps of Engineers (USACE), New England District (NAE) intends to require, on a brand-name basis, the purchase and installation of highly specialized hydraulic and electronic components for the upcoming Stamford Hurricane Barrier Control System Replacement project in Stamford, Connecticut. The Stamford Hurricane Barrier is a critical life-safety public infrastructure asset providing immediate tidal flood and storm surge protection to the City of Stamford and surrounding communities. The brand-name components specified herein are manufactured by: Bosch Rexroth HYDAC Des-Case Honeywell (Sensotec) Dwyer Omega Lisle Corporation These components are required for the rehabilitation, modernization, and control integration of the existing main Hydraulic Power Units (HPUs) and hydraulic manifold assemblies. The use of these brand-name components is essential to meet the Government’s strict safety, compatibility, and performance requirements for the following reasons: The project requires direct integration with the existing HPU structures and manifolds, which were originally designed and manufactured by Rexroth. The new components must be fully compatible with the existing proprietary hydraulic flow paths, mechanical port configurations, and pressure curves. The barrier's two massive gate cylinders must operate in perfect synchronization to prevent twisting, binding, and potential catastrophic mechanical failure. The specified Bosch Rexroth proportional and counterbalance valves possess proprietary flow-gain curves and spool alignments that are essential to ensure this synchronized movement. Using any other manufacturer's valves would introduce a mismatch, inducing severe structural stress on the barrier. The existing manifolds are machined with proprietary Rexroth cavity and mounting standards. Generic commercial valves and filters will not seat properly without custom adapters, which would introduce leak paths and degrade system reliability. The specified components ensure a precise physical fit within the existing infrastructure. Schedule of Intended Brand-Name Components To afford industry full visibility to review and provide feedback, the intended schedule of brand-name components is itemized below by contract drawing schedules: HPU Replacement Parts Quantities reflect the complete project scope across both East and West Abutment HPUs (2 HPUs total). Tech Pos Description / Function Manufacturer Specified Model / Part Number Qty / HPU Total Project Qty 12 3/4" Square-Head Magnetic Trap Plug Lisle Corporation Part No. 4054121 2 4 20 Float Level Switch Assembly Bosch Rexroth Model 800PUA31-05 3 SW (Part No. R978835263) 2 4 25 Reservoir Filler Connection / Cap Bosch Rexroth Model F/ELF5-10-2.0 PUA42-11 (Part No. 97884631) 2 4 30 Desiccant Breather & Mounting Adapter Des-Case Breather DC/CS-4 & Adapter DC-12 (Part Nos. R978839894 / R978840030) 2 4 35 Temperature Switch Bosch Rexroth Model TEMP SW PUA31-30B E55-14103 (Part No. 97888127) 2 4 40 Bulbwell Steel (11.44" Long) Bosch Rexroth Model BULBWELL 11.44 LG PUA31-22 (Part No. R978802575) 2 4 43 Temperature Transducer (RTD) Dwyer Omega Model PR-12-2-100-1/4-12-E 2 4 44 Bulbwell for Temperature Transducer Dwyer Omega Model 3/4-260S-U10 2 4 45 Bimetal Thermometer Bosch Rexroth Model BIMET PUA31-14 WIKA 33X0278 (Part No. 978804856) 2 4 50 Bulbwell Steel (5.25" Long) Bosch Rexroth Model BULBWELL 5.25 LG PUA31-22 (Part No. 978804619) 2 4 75 High-Pressure Filter Assembly HYDAC Model DF BH/HC 330 T F 10 D 1.0 /-L110-B6 (Part No. 1250576) 2 4 77 Return Line Filter Assembly HYDAC Model RF BN/HC 30 B B 10 D 1.0 /-L110 (Part No. 1266488) 2 4 80 3/4" Check Valve (0.5 bar cracking) Bosch Rexroth Model S15A05-1X/420/12 4 8 85 1-1/2" Check Valve (0.5 bar cracking) Bosch Rexroth Model S30A05-1X/420/12 (Part No. R901454196) 4 8 93 Low-Pressure Gauge Assembly Bosch Rexroth Model GSA 4/400PUA31-10A (Part No. 978837831) 2 4 95 High-Pressure Gauge Assembly Bosch Rexroth Model GSA 4/3000PUA31-10A (Part No. 978837833) 2 4 110 Direct-Operated Relief Valve Bosch Rexroth Model DBDS15G1X/50-12 (Part No. 900534613) 2 4 120 Pilot-Operated Relief Valve Bosch Rexroth Model DBW15BG2-5X/315-6EW110N9K4/12 (Part No. 978917231) 2 4 Manifold Wearable Components Quantities reflect the complete project schedule for the dual-cylinder manifold assemblies. Item / Tech Pos Description / Function Manufacturer Specified Model / Part Number Manifold Schedule Qty 201.1 High-Pressure Transducer (0–2000 psi) Honeywell (Sensotec) Model Sensotec AP415DL (Part No. 60-F499-01) 6 203.1 Low-Pressure Transducer (0–500 psi) Honeywell (Sensotec) Model Sensotec AP415CR (Part No. 60-F441-01) 2 219 Directional Valve Bosch Rexroth Model 4WE6D5X/AW120-60NDA/5 (Proportional directional valve w/ OBE) 2 220 Proportional Directional Valve Bosch Rexroth Model 4WRZ16-15005X/6A24N9TD3/M-116 (Proportional directional valve w/ OBE) 2 223 Pressure Compensator Bosch Rexroth Model ZDC16P-2X/M (Part No. R900489668) 2 225 Counterbalance Valve Bosch Rexroth Model FD25KA2X/B04/12 (Part No. R900518087) 2 Salient Characteristics and Technical Rationales The use of the specified brand-name components is essential to meet the Government’s strict life-safety, mechanical synchronization, fluid cleanliness, and physical compatibility requirements. Bosch Rexroth (Hydraulic Valves, Controls, and Switches): The existing HPUs and distribution manifold blocks were originally engineered and machined to proprietary Rexroth cavity and porting standards. Replacement valves must drop directly into existing cavities without adapter plates, which introduce leak paths and structural compliance issues. The barrier gate is actuated by two massive hydraulic cylinders on opposite sides of the navigational opening. These cylinders must operate in strict displacement and velocity synchronization to prevent mechanical twisting, binding, and structural failure. Rexroth proportional (Item 220) and counterbalance valves (Item 225) possess proprietary flow-gain curves, matched spool alignments, and factory-calibrated on-board electronics (OBE) essential to maintaining synchronized motion. HYDAC (Pressure and Return Line Filtration): The close-tolerance proportional valves require hydraulic fluid (Mobil DTE 10 Excel 32) maintained strictly at ISO 4406 cleanliness rating 17/15/12. HYDAC Betamicron filter elements provide the validated single-pass Beta ratio (β10(c) ≥1000) required to prevent spool erosion and sticking. The filter assemblies match existing piping brackets and incorporate integral clogging indicators (110V/B6 signal outputs) that wire directly into the PLC input modules. Des-Case (Desiccant Breathers & Adapters): In a harsh marine environment, humid and salt-laden air entering the reservoir causes rapid oil emulsification and valve corrosion. Des-Case DC/CS-4 breathers utilize high-efficiency silica gel media coupled with 3-micron particulate filtration and bi-directional internal check valves. The DC-12 quick-flange adapter interfaces directly with existing reservoir cover plates, providing a hermetic, vibration-proof seal without field drilling or hot-work near oil reservoirs. Honeywell Sensotec (Precision Pressure Transducers): The automated control system monitors real-time cylinder pressure to balance load sharing and detect hydraulic stalls. Honeywell Sensotec AP415DL and AP415CR transducers are electrically matched to the scaling tables and signal registers programmed into the PLC analog cards. Feature high-pressure flush-diaphragm threaded connections engineered to seal into existing Rexroth manifold sensor cavities without pipe-thread adapters. Dwyer Omega (Temperature Transducers / RTDs): Cold hydraulic oil degrades proportional valve response time. The Dwyer Omega PR-12E RTD temperature sensor monitors reservoir fluid temperature to manage immersion heaters and prevent barrier deployment when fluid viscosity exceeds safe operating thresholds. Features 1/4" NPT threads and probe immersion dimensions matching existing reservoir thermowells. Lisle Corporation (Magnetic Reservoir Trap Plugs): Captures recirculating microscopic ferrous wear particles that escape surface filters, protecting high-pressure pump pistons and valve spools. Engineered with heavy-duty 3/4" square-head profiles that seat into existing tank cleanout ports and resist stripping during routine maintenance. Submission of Capabilities: THIS IS A NOTICE OF INTENT, NOT A REQUEST FOR COMPETITIVE PROPOSALS OR A SOLICITATION. A solicitation will be issued at a later date. However, any firm that believes it can provide alternative components that meet all the critical salient characteristics (e.g., mechanical footprint, flow-gain curves, porting, sensor scaling) and can demonstrate how using such components would not compromise the operational safety and synchronization of the Stamford Hurricane Barrier may submit a capability statement. This notice is a market research tool being used to determine the availability of other qualified sources that can meet the requirements identified above. The Government is not obligated to and will not pay for any information received because of this notice. All responses received within 15 days of the posting of this notice will be considered by the Government. A determination by the Government to require the specified brand names is solely within the discretion of the Government. Submit responses within 15 days of the posting of this notice of intent via email to: Distephano.Marcellus@usace.army.mil (list “W912WJ27BA001 – Stamford Hurricane Barrier Mechanical Components” in the subject line of the email). | Special Notice | 238210 | No Set-Aside | 09/17/2026 | 10/02/2026 | Stamford, CT | |
The U.S. Army Corps of Engineers - New England District is issuing a Presolicitation Notice for Dike B Generator Installation, Mansfield Hollow Dam, Mansfield Center, CT. QUESTIONS REGARDING THE PROCUREMENT WILL NOT BE ANSWERED DURING THE PRESOLICITATION PHASE. SUBMIT QUESTIONS TO THE CONTRACT SPECIALIST AFTER THE SOLICITATION AND ASSOCIATED DOCUMENTS HAVE BEEN POSTED. THE WORK CONSISTS OF: The Contractor shall furnish all necessary materials, equipment, and labor required to construct and commission a new power system for the Dike B Operator unit. The scope of work involves comprehensive site preparation to support the construction of a reinforced concrete generator pad and the installation of secure perimeter fencing. The Contractor is responsible for the procurement and installation of a standalone, propane-powered generator and a corresponding propane fuel storage tank. Following the physical installation, the Contractor shall execute all final electrical connections and integration into the existing sluice gate operator unit and control panel. All work shall comply with all applicable federal, state, and municipal laws and codes, and shall be completed in accordance with the Statement of Work. This is not a request for quotes at this time. The solicitation requirements and contract documents, to include instructions for submission, and the response date will be available on or about October 1, 2026. Neither telephonic, mailed nor faxed requests for hard copies of this solicitation will be accepted. The solicitation will only be available online; in order to download the solicitation offerors must access the Contract Opportunities website (www.SAM.gov). This procurement is set-aside for small business vendors. The applicable NAICS code is 238210 with a Small Business Size Standard of $19 Million. ALL VENDORS MUST HAVE AN ACTIVE REGISTRATION IN SAM.GOV AT THE TIME OF SUBMISSION IN ORDER TO BE CONSIDERED. ANY VENDOR THAT DOES NOT HAVE AN ACTIVE SAM.GOV REGISTRATION WILL BE REJECTED AS NON RESPONSIVE. | Pre-Solicitation | 238210 | Total Small Business Set-Aside | 09/14/2026 | Open | Mansfield Center, CT | |
The U.S. Army Corps of Engineers, New England District is solicitating an Invitation for Bids (IFB) for Electrical Feeder Upgrades at the Black Rock Lake Dam in Thomaston, Connecticut. This will be a 100% Small Business Set-Aside IFB procurement. The NAICS code for the work described below is 238210 with a size standard of $19M. The project is planned to be issued in July 2026 and will be set aside for Small Businesses. The period of performance will be approximately 180 days. The estimated magnitude of this project is between $750,000 and $1,250,000.The work of this project involves electrical feeder upgrades at the Black Rock Lake Dam in Thomaston, Connecticut. Specific work tasks include, but are not limited to, replacing the existing overhead dam feeder (which runs underneath a high voltage line) from the project office to a designated manhole with a buried conduit duct bank.The existing gate tower feeder is in an existing buried duct bank which runs up the dam face and in exposed conduit beneath the gate tower bridge will be removed and replaced with new. The fused disconnect at the existing overhead line end will be removed. The existing manual transfer switches in the gate tower and project office will be removed. The existing 480V Panel-A, transformer, and 120/208 Panel-B in the gate tower will be removed and replaced with new. The existing service entrance circuit breaker and its enclosure will remain and be reused. Install new propane genset in the project office parking lot. Install a new propane tank with an underground propane line connected to the genset. The new genset will be sized to power both the project office and the gate tower on loss of utility. The propane tank will be sized to provide 5 days of run time before needing to be refilled. Install a new properly sized automatic transfer switch to feed existing panel MDP-1 from either the existing utility feeder or the new propane genset. | Solicitation | 238210 | No Set-Aside | 09/11/2026 | 09/10/2026 | - | |
The U.S. Army Corps of Engineers, New England District is solicitating an Invitation for Bids (IFB) for Electrical Feeder Upgrades at the Black Rock Lake Dam in Thomaston, Connecticut. This will be a 100% Small Business Set-Aside IFB procurement. The NAICS code for the work described below is 238210 with a size standard of $19M. The project is planned to be issued in July 2026 and will be set aside for Small Businesses. The period of performance will be approximately 180 days. The estimated magnitude of this project is between $750,000 and $1,250,000.The work of this project involves electrical feeder upgrades at the Black Rock Lake Dam in Thomaston, Connecticut. Specific work tasks include, but are not limited to, replacing the existing overhead dam feeder (which runs underneath a high voltage line) from the project office to a designated manhole with a buried conduit duct bank.The existing gate tower feeder is in an existing buried duct bank which runs up the dam face and in exposed conduit beneath the gate tower bridge will be removed and replaced with new. The fused disconnect at the existing overhead line end will be removed. The existing manual transfer switches in the gate tower and project office will be removed. The existing 480V Panel-A, transformer, and 120/208 Panel-B in the gate tower will be removed and replaced with new. The existing service entrance circuit breaker and its enclosure will remain and be reused. Install new propane genset in the project office parking lot. Install a new propane tank with an underground propane line connected to the genset. The new genset will be sized to power both the project office and the gate tower on loss of utility. The propane tank will be sized to provide 5 days of run time before needing to be refilled. Install a new properly sized automatic transfer switch to feed existing panel MDP-1 from either the existing utility feeder or the new propane genset. | Solicitation | 238210 | No Set-Aside | 09/08/2026 | 09/10/2026 | - |
Additional Details
Solicitation Number
70Z0G126SCCODReplaceMediumVoltageCutoffSwitches
Archive Date
Jan 15, 2026
Office Address
WARWICK, RI, 02886