GovChime
Notice ID: 1a8af077f9a74b35963e4c47cfe527cfPresolicitationArchived

Multisizer 4e Coulter Counter

Archived on June 3, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
9:00 AM EDT
Posted
May 22, 2026
Notice type
Presolicitation
Set-aside
No Set aside used
NAICS
334516: Analytical Laboratory Instrument Manufacturing
Agency
Department of Health and Human ServicesNATIONAL INSTITUTES OF HEALTH

Notice details

Office
NATIONAL INSTITUTES OF HEALTH OLAO
Place of performance
Maryland, 20892
PSC
6640: LABORATORY EQUIPMENT AND SUPPLIES
Last updated
Oct 29, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
75N98026Q00434
Notice ID
1a8af077f9a74b35963e4c47cfe527cf

Description

The required Multisizer provides improved functionality and analysis capabilities, in addition to allowing continued measurement of cell size, counts, and distribution using the Coulter method across multiple clinical research study protocols. 

                                                  Specifications & Requirements

                        The product shall include/use: 

  • Coulter method of measurement using patented digital pulse processing technology 

  • Automatic aperture blockage detection and clearing during runs and sample analysis 

  • Code scanner to scan bar codes on samples, electrolytes, aperture tubes, and sample beakers 

  • Fluid level monitoring for solutions and waste 

  • Selectable stirrer speed and direction 

  • Particle sizing range: 0.2 – 1,600uM 

  • Measurement range: 2 – 80% of aperture size 

  • Measurement linearity: Diameter ± 1%, Volume ± 3% 

  • Dynamic range (accuracy): 1:40 (diameter), 1:64,000 (volume) 

  • Accurate determination of sample cell number, size, distribution, and concentration 

  • Particle count, sizing, and volume distribution data, including diameter, volume, and area of number, number percent, number per mL, volume, volume percent, volume per mL, surface area, surface area percent, surface area per mL 

  • Pulse distribution data, including time, sequence and width for pulse height diameter, pulse height volume, pulse height volt, pulse width, pulse area, average pulse height diameter, average pulse height volume and average pulse width. Number distribution by width. 

  • Up to 400 size classes or channels with the ability to change number of size classes or channels and width and reprocess as needed without having to re-run the samples 

  • Time-stamped pulses up to 525,000 per single analysis 

  • Modes for Total Count (up to 500,000 counts), Modal Count (up to 100,000 counts), and Volumetric Count (up to 2000uL) 

  • Digital Pulse Processor with proprietary high-speed signal digitalization 
  • Real time detection of volume changes 

  • Stirrer with ability to adjust stir speed and direction for even particle distribution in sample suspensions 

  • 100uM and 400uM size aperture tubes, with instrument ability to use apertures ranging from 10uM up to 2000uM size as needed, with aperture tube calibration and verification 

  • 100/200mL beakers, with ability to use additional size beakers and accuvettes, as required by the sample type, sample volume, or other need 

  • Isoton II Diluent and Coulter Clenz solutions for instrument operation and cleaning, and spigot assemblies for both solutions 

  • Mixed Standards Kit (L2, L5, L10, L20, L40) 

  • 300uM Particle Standard 

  • Installation 

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Documents

Files (1)

  • Specifications Requirements rev2.docx

    19 KBAdded in Presolicitation version 3Posted
    Download

Lifecycle

  1. 3
    Version 3PresolicitationArchivedCurrent

    Multisizer 4e Coulter Counter

    Notice 1a8af077f9a74b35963e4c47cfe527cf on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

75N98026Q00434

Archive Date

Jun 3, 2026

Office Address