GovChime
Notice ID: 3a392e9f6d03923441f1bc49dd2c43baCombined Synopsis/Solicitation

Custom Fuel Truck Chassis and Tank

Archived on September 8, 2018. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
2:00 PM UTC−06:00
Posted
August 21, 2018
Notice type
Combined Synopsis/Solicitation
NAICS
237120: Oil and Gas Pipeline and Related Structures Construction

Notice details

Place of performance
NASA/MSFC
PSC
38: CONSTRUCT/MINE/EXCAVATE/HIGHWY EQPT
Last updated
Jan 23, 2026

Identifiers

Solicitation number
80NSSC18Q1168
Notice ID
3a392e9f6d03923441f1bc49dd2c43ba

Description

Please see attached RFQ

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

Showing 1 of 1 items

Document
Source
Agency
Posted Date
File Size
Actions
Combined Synopsis/SolicitationSAM.govAug 21, 2018-

Lifecycle

Solicitation:80NSSC18Q1168
  1. Combined Synopsis
  1. Combined SynopsisCurrentAug 21, 2018

    Custom Fuel Truck Chassis and Tank

    Notice 3a392e9f6d03923441f1bc49dd2c43ba on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Project is located in Mather, CA. Includes all work to install a sampling gauge hatch on a manway, install a clock type mechanical gauge on a manway, recoat the exterior of the tank, replace the collision barriers, add a catwalk that extends across the entirety of the tank, and replace the audible and visual alarms. o Fix the remote containment basin drainage issue. o Replace the asphalt on the NE side of the fueling facility. o Repair the refueler parking concrete. o Replace the dispenser fuel monitor with a non-coalescing filter and install a water draw off system with a hand pump. o Replace the asphalt near the loading/unloading facility with a concrete path. o Replace POL building of the same size and at the same location. o Complete supplying, installation, and testing ATG system on Fuel Storage Tank, AVGAS. o Relocate the generator that is inside the compartmentalized area.
-Solicitation12/04/2026
This is a combined synopsis/solicitation for construction services. Solicitation 36C26027R0029 is issued as a Request for Proposal (RFP). This solicitation is conducted in accordance with FAR Part 15, Contracting by Negotiation, and FAR Part 36, Construction and Architect-Engineer Contracts, as applicable, including any Revolutionary FAR Overhaul (RFO) deviations in effect on the solicitation issue date. This announcement constitutes the only solicitation; proposals are being requested. This solicitation is a total Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside. The associated NAICS code is 237120, Oil and Gas Pipeline and Related Structures Construction, and the small business size standard is $45.0 million in average annual receipts. To be eligible for consideration and award, an offeror must meet all of the following at the time of proposal submission and at the time of award: 1. Be certified as a Service-Disabled Veteran-Owned Small Business (SDVOSB) by the U.S. Small Business Administration (SBA), with active certification shown in the SBA database. 2. Have an active registration in the System for Award Management (SAM), www.sam.gov, that lists NAICS code 237120 and represents the offeror as a small business under that NAICS code. 3. Offerors must submit a bid bond with their proposal. An offeror that does not meet these requirements will be ineligible for award. DESCRIPTION: The Department of Veterans Affairs, VA Puget Sound Health Care System, has a requirement for a Contractor to provide Under Dispenser Containment (UDC) and Sump Installation, Project 663A4-27-001, at the American Lake Campus, 9600 Veterans Drive SW, Tacoma, WA 98493. SITE VISIT: One site visit is scheduled for November 10, 2026, from 08:00 to 11:00 a.m. PST at the American Lake Campus. Advance confirmation of attendance is required. See Attachment: Site Visit, for instructions. TERMS: This requirement incorporates one or more clauses and provisions by reference, with the same force and effect as if they were given in full text. The full text of a clause or provision may be accessed at http://www.acquisition.gov/far/index.html and http://www.va.gov/oal/library/vaar/. Offerors are encouraged to, and responsible for, reviewing the full solicitation (attached) for the detailed requirement description, applicable terms and conditions, provisions, proposal submission instructions, and evaluation procedures before submitting proposals. All offerors must have an active registration in the System for Award Management (SAM), www.sam.gov, at the time of submittal. QUESTIONS: Any questions about this requirement must be sent by email only to derek.crockett@va.gov no later than 12:00 PST on November 12, 2026. Solicitation 36C26027R0029 in the subject line of the email. Responses to questions will be posted as an amendment to the solicitation once the question period has expired. Offerors are responsible for monitoring Contracting Opportunities at www.sam.gov for any amendments, as the Government will not send notice of amendments. Representatives of potential offerors shall not contact any VA Medical Center representative to discuss or inquire about this solicitation. Telephonic questions will not be accepted.
-Combined Synopsis11/17/2026
***This solicitation is a Small Business set-a-sided, restricted to 100% small business only.***The project includes repairs and upgrades to an existing fuel storage and dispensing facility. Work includes repairing concrete and pavement; removing water from an underground communications access box; installing an emergency fuel shutoff station and leak detection equipment; and repairing and recoating fuel system canopies, piping, and related components. Additional work includes replacing tank vents, repairing and improving grounding systems, modifying platforms to provide safe access to tank equipment, and upgrading the automatic tank gauging (ATG) system and associated controls.*****Proposal Due Date has been extended from 11/23/2026 to 12/21/2026 at 14:00 CST*****
-Solicitation11/23/2026
This is a SOURCES SOUGHT notice; a market survey for information only, to be used for preliminary planning purposes. This is NOT a request for quotes or proposals. The intent of this notice is to identify qualified, experienced, and interested offerors capable of performing the type of work as described herein for information and planning purposes. The information received will be utilized by the United States Air Force to facilitate the planning and decision-making process and will not be disclosed outside of the agency. No reimbursement will be made for any costs associated with providing information in response to this announcement or any follow-up information requests. Respondents will NOT be notified of the results of this sources sought. Respondents are not required to submit information in response to this announcement to participate in any future solicitation that may come as a result of the information received. In accordance with Revolutionary Federal Acquisition Regulation Overhaul (RFO) 15.101(c)(2), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The 55th Contracting Squadron, Offutt Air Force Base, NE, is seeking information for the following items listed below: General: The purpose of this sources sought is to conduct Market Research in accordance with RFO Part 10, for the repair and replacement of existing gas leaks on 6” pipe and 8” pipe and valves, along with some associated component replacement on 2” pipe and valves. This requirement consists of repairing and replacing identified gas distribution system components, site verification, coordination for excavation, system outages, Lock-Out-Tag-Out, utility coordination, and operational testing. Please see the attached Statement of Work for more information. All project work and related services shall be performed IAW all terms, conditions, special contract requirements, specifications, attachments, technical exhibits and references and publications contained in the contract or incorporated by reference. All information is voluntary. The capabilities package should be complete and sufficiently detailed enough to allow the Government to determine the firm’s qualifications to perform the defined work. Your response should include the following information: Company Information Company name Address Point of contact Telephone and fax number E-mail address Website (if available) Commercial and Government Entity (CAGE) Code Unique Entity ID (UEI) Number Socio-Economic status (i.e., 8(a), HUBZone, women-owned, service-disabled veteran-owned, etc.) Experience and overview of your company Responses to this sources sought announcement can be submitted to the 55th Contracting Squadron via e-mail to gabriel.holcombe@us.af.mil by 12:00 PM Central Standard Time on 17 November 2026. IF A SOLICITATION IS ISSUED, IT WILL BE ANNOUNCED AT A LATER DATE. All interested parties must respond to any solicitation announcement separately from the responses to this announcement. No reimbursement will be made for any costs associated with providing information in response to this announcement.
-Market Research11/17/2026
Description This is a solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 75110PR270000104 is issued as a request for quotation (RFQ) for gas-leak detection and repair, gas-valve installation, gravel backfill, asphalt patching, and site cleanup at Birmingham Southern College in Birmingham, Alabama. This acquisition is set aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01 Effective Date 03/13/2026. The associated North American Industrial Classification System (NAICS) code for this procurement is 237120, with a small business size standard of $45.0M. Product Service Code is Z2NA. Submission of offers. Submit signed and dated offers to the office specified in this solicitation at or before the exact time specified in this solicitation. As a minimum, offers shall include— (1) The solicitation number. (2) The name, address, telephone number of the Offeror. (3) The Offeror’s Unique Entity Identifier (UEI) (4) Information necessary to evaluate the factors contained in the provision at 52.212-2 (5) Responses to provisions that require Offeror completion of information, representations, and certifications (other than those collected via the System for Award Management (SAM)); and (6) A statement specifying the extent of agreement with all terms, conditions, and provisions included in the solicitation and any solicitation amendments. Period for acceptance of offers. The Offeror agrees to hold the prices in its offer firm for 30 calendar days from the date specified for receipt of offers, unless another time period is specified in an addendum to the solicitation. The Coast Guard Training Center Birmingham Southern is seeking to purchase gas-leak repair services, including excavation, gas-line repair, gas-valve installation, testing, gravel backfill, asphalt patching, and site cleanup. All interested companies must provide quotation(s) for the following services: CLIN 0001 — Gas Leak Detection, Excavation, Spoil Removal, and Gravel Backfill. The Contractor shall locate the gas leak, saw-cut and excavate the parking lot as needed, use required safety measures, remove and dispose of excavated material and debris, and place and compact clean gravel or approved backfill after repair and testing. The expected excavation area is about 6 feet by 6 feet and up to 6 feet deep. The Government will provide utility markings before excavation; however, the Contractor remains responsible for safe digging. This CLIN is associated with SOW Task 2.1, SOW Task 2.3, and SOW Section 5.0. CLIN 0002 — Gas-Line Repair, Valve Installation, Testing, and Test Record. The Contractor shall provide all labor, materials, equipment, pipe, fittings, connectors, one new gas shutoff valve, and testing needed to repair the identified gas leak. The Contractor shall test the repaired gas line and valve before backfill and provide a written test record to the GTR and Contracting Officer. The Contractor shall not restart gas service until testing is successful and any required gas-utility approval is received. This CLIN is associated with SOW Task 2.2. CLIN 0003 — Asphalt Repair. After the gas-line repair, testing, and backfill are complete, the Contractor shall prepare the base and install an asphalt patch. The patch shall match the existing pavement as closely as practical, be properly compacted and level with the surrounding surface, and be safe for normal parking-lot traffic. The Contractor shall seal edges and joints as needed. This CLIN is associated with SOW Task 2.3. CLIN 0004 — Site Cleanup and Demobilization. The Contractor shall remove all debris, spoils, excess materials, equipment, signs, barriers, and temporary items from the work area. The Contractor shall leave the site clean, orderly, and safe for normal use. This CLIN is associated with SOW Task 2.4. Reference Attached Statement of Work in Solicitation 75110PR270000104 The period of performance for this firm-fixed-price contract must not exceed ten (10) business days from the date of award. All work, including final cleanup and demobilization, must be completed within this period Place of Performance The primary place of performance is the parking lot at Coast Guard Training Center Birmingham Southern, 900 Arkadelphia Road, Birmingham, AL 35204. 52.237-1 Site Visti (Apr 1984) To facilitate this process, an organized site visit has been scheduled for November 5, 2026, at 10:00am cst. Participants are requested to assemble at Training Center Birmingham main gate. Please note that all visitors must provide the following information prior to scheduling a site visit: full legal name, date of birth, contact number, email address, Real Id Driver’s License, registration of vehicle and proof of insurance. No personnel with felony convictions are permitted to access Coast Guard facilities under any circumstance. All vendors interested in attending a site visit shall submit their request and information by sending an email to john.h.caicedo2@uscg.mil with the following information: 1: Company Name 2. Company Phone 3: Visitor Name 4: Last 4 of SSN: 5: Date of Birth: 6: Place of Birth: 7: Real Id Driver’s License Number:
-Solicitation11/12/2026

Additional Details

Solicitation Number

80NSSC18Q1168

Archive Date

Sep 8, 2018