Notice ID: 88125c744e0849cdbea1c1f304883d0fAward NoticeAwarded
LAANG HANGAR 5 FIRE SYSTEMS REPAIR NAS JRB NEW ORLEANS, LA
Awarded on September 23, 2026. Full description on SAM.gov.
Awarded tounder N6945019D1088 (source: SAM.gov award notice)• $10.5M
Overview
- Posted
- September 23, 2026
- Notice type
- Award Notice
- NAICS
- 238210: Electrical Contractors and Other Wiring Installation Contractors
- Agency
- Department of WarDepartment of the Navy
Notice details
- Office
- NAVFAC.NAVFAC ATLANTIC CMD.NAVFAC SOUTHEAST.NAVFACSYSCOM SOUTHEAST
- Place of performance
- Naval Air Station JRB, 400 Russell Ave, New Orleans, LA 70143, 70143
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
- Award date
- Sep 23, 2026
- Award amount (SAM.gov award notice)
- $10.5M
Identifiers
- Solicitation number
- N6945026RDC24
- Notice ID
- 88125c744e0849cdbea1c1f304883d0f
- Award number (PIID)
- N6945019D1088
Description
LAANG Hangar 5 Fire System Repairs (Current Mission): upgrades/replacement of the fire protection systems to in the hangar bay to comply with the Department of the Air Force Sundown Policy for Foam Fire Suppression Systems memorandums dated 16 November 2021 (AF Tab1), 18 January 2022 (AF Tab2), and Fire Suppression Design Change Instruction and Code Criteria Update, Naval Air Station Joint Reserve Base, RQLH142018, Repair Maintenance Hangar, B5. LAANG Hangar 5 is categorized as a Tier 2 Facility. Project includes demolition of the existing low-level fire suppression system in the hangar bay(previously AFFF system), demolition of the overhead wet-pipe sprinkler systems in the hangar bay(previously AFFF), installation of new wet-pipe fire sprinkler system(s) and detection system in the hangar bay, replacement of the fire alarm system throughout the entire building with a new fire alarm/mass notification system (MNS), addition of aircraft power service points, repurposing of existing space as a battery shop, and related repairs/upgrades.
Award Overview
Award Number
N6945019D1088
Award Amount (SAM.gov award notice)
$10.5M
Award Date
Sep 23, 2026
Awardee
Awardee UEI
L76UENTDZN29
Awardee CAGE Code
0SXZ4
Awardee Address
3805 FAYE RD, JACKSONVILLE, FL 32226, UNITED STATES
Delivery Order Number
N6945026F0525
Line Item Number
0001
Original Solicitation
Notice ID: 88125c744e0849cdbea1c1f304883d0f
Posted Date: Sep 23, 2026
Original Response Deadline: Not specified
Task Orders Under This IDV
Top 10 by total obligated
- $11.5MSigned Jun 4, 2026
- $11.4MSigned Nov 14, 2023
- $5.7MSigned Apr 17, 2026
- $5.4MSigned Jun 30, 2026
- $5.0MSigned Sep 26, 2022
- $4.8MSigned Aug 9, 2024
- $4.8MSigned May 20, 2024
- $4.1MSigned Dec 12, 2022
- $4.1MSigned Sep 26, 2019
- $4.1MSigned Feb 3, 2022
More From This Vendor
Top 5 most recent
- $5.4MSigned Jun 30, 2026
- $11.5MSigned Jun 4, 2026
- $5.7MSigned Apr 17, 2026
- $3.7MSigned Sep 24, 2025
Contacts
Contracting Officer
Primary Contact
Documents
Links (4)
- PIEE Solicitation Module Link for N6945026RDC24piee.eb.milPosted
- Web Based Training for the PIEE Solicitation Modulepieetraining.eb.milPosted
- Registration Instructions for the PIEE Solicitation Modulewww.acq.osd.milPosted
- Department of Defense Procurement Toolboxdodprocurementtoolbox.comPosted
Lifecycle
- 1Version 1Award NoticeCurrent
LAANG HANGAR 5 FIRE SYSTEMS REPAIR NAS JRB NEW ORLEANS, LA
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
The Department of Veterans Affairs, James A. Haley VA Medical Center is currently seeking information from any Service Disabled Veteran-owned Small Business (SDVOSB), Veteran-owned Small Business (VOSB), or Small Business (SB) vendors that can provide the following service. SCOPE OF WORK: The Contractor shall provide all labor, travel, parts, materials, transportation, equipment, tools, training, supplies, management and supervision to perform circuit tracing and documenting electrical circuits within the critical and non-critical areas of Building 1. The Contractor shall furnish all labor, equipment, sanitized, disinfected and labels for containers, supplies, materials, transportation and supervision required to provide pick up, transport, incineration and/or acceptable disposal of biomedical infectious, veterinary, chemotherapy, biological/pathological, sharps waste, and contaminated wastes. 1. Period of Performance:Â The period of performance for this contract 365 days from the Kickoff meeting or the Notice to proceed from the Contracting Officer. Government is aware that scheduling may be difficult at times and an extension may be needed. Contractor will notify the COR, and an extension can consist of Month-by-Month basis (up to 12 months). Tracing will include not limited to: Safely trace and document electrical circuits feeding hospital departments, including critical care areas. Ensure accurate identification of power sources for all outlets, devices, lighting, and life safety systems. Locate/trace electrical panels throughout building Label panels, breakers, and field devices to support fast emergency response and future maintenance. Produce comprehensive documentation in support of NFPA 99, NFPA 70 (NEC), and The Joint Commission requirements. Labeling panel schedule to reflect panel locations/line/loads. Determine amperage/voltage draw of panel loads. Ensure panel is following hospital codes/regulations Contractor shall apply compliant, durables labels to: Panelboard and breakers Device faceplates (outlets, switches) Subpanels and junction boxes Include power source panel and circuit number on each label. Emergency power circuits will be labeled with distinct color codes or markings. Summary Report: A comprehensive report including findings, panel schedules, and recommendations will be furnished after completion of work if applicable. Contractor shall Develop detailed circuit maps and panel schedules. Identify emergency vs normal power sources. Document any undocumented circuits, discrepancies, or safety issues. Submit digital and hard copy reports in a facility-approved format to the VA within 7 days of completion. Information shown in the report shall be as following: Company s name, addresses, telephone, & FAX numbers. Name and signature of contractors who perform the Circuit Tracing. VA Work Contract Number, name and number of VA Contracting Officer. Date and Time of work. Copies of contractors valid licenses, professional and training certificates. Descriptions and model number of specialized tools and equipment used. Such as (Fluke 2062 Advanced Pro Wire Tracer) Traced Location, Type, Name, and nameplate information of electrical equipment, labeled electrical circuits throughout designated areas. Updated panel schedules (digital + printable formats). Room-by-room circuit tracing maps. Emergency vs normal power path diagrams. Summary report with deficiencies, abandoned circuits, and suggested corrective actions Remarks on conditions of electrical equipment. List all deficiencies, Recommended corrective actions, if any. BACKGROUND: The electrical system throughout building 1 needs to have the circuits traced and labeled correctly. This work will be performed in patient rooms, ICU, NICU and other critical care units, Administrative and support spaces. Upon investigating the electrical systems for information to assist the maintenance operation section with shutdowns/additions/repairs/upgrades, it has been determined the panel schedules are not correct. Without having correct information, we unintentionally interfere with DIRECT PATIENT CARE and hospital operations. It now takes a minimal of 40-60 manhours to physically trace out a panel circuit to try and plan a more efficient shutdowns to minimize interruptions to patient care and hospital operations. The above issues are becoming critical and costing thousands of dollars in investigating. The applicable NAICS for this service is 238210, Electrical Contractors and Other Wiring Installation Contractors . To be considered for this requirement, vendors must be registered in the System for Award Management (SAM - https://www.sam.gov). Any vendor interested in this requirement should include the following information: Company Information (business name, UEI number, business size/category, GSA schedule if applicable) Capability Statement (brief background of capabilities, resources, experience, etc.) Contact information (POC name, email, and phone) All information regarding this requirement will be posted on Contracting Opportunities. All responses to this request for information notice shall be submitted to the following email address: keila.president@va.gov. The closing time/date for responses is 11/11/2026 @ 2:00 pm EST. This request for information is for market research purposes only. THIS IS NOT A SOLICITATION AND DOES NOT REQUIRE THE GOVERNMENT TO ISSUE A SOLICITATION. The Government will not pay for any information submitted under this notice. DISCLAIMER This request for information is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this request for information that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. | - | Market Research | 11/11/2026 |
End of Amendment 0002 | - | Solicitation | 11/06/2026 |
The USDA Office of Contracting and Procurement (OCP), on behalf of the USDA Animal and Plant Health Inspection Service (APHIS), Veterinary Services (VS), intends to award a firm-fixed-price purchase order on a sole-source basis to Advanced Control Corporation, Inc., for the modernization of the existing EcoStruxure Building Operation system at the USDA APHIS VS Animal Import Center located in Miami, Florida. The requirement includes replacing obsolete building automation controllers, integrating replacement components with the existing system, and performing associated programming, testing, and commissioning. Advanced Control Corporation originally installed and currently maintains the existing system. The proposed modernization requires compatible equipment and integration with proprietary controls while retaining functioning infrastructure and maintaining essential temperature monitoring and control capabilities. This notice is not a request for competitive quotations. However, all responsible sources that believe they can meet the requirement may submit a capability statement for Government consideration. Additional information and response instructions are provided in the attached presolicitation notice. | - | Special Notice | 11/19/2026 |
1. General: Project Location: C.W. Bill Young VA Medical Center located at, 10000 Bay Pines Blvd. Bay Pines, FL. 33744. These nine (9) emergency exit signs fixtures are for the Laundry Building (Building 13) by the Project Manager: Dale McDowell, Fire Protection Engineer. 2. Purpose: Provide all labor, materials, equipment, supervision, and testing necessary to furnish and install nine (9) illuminated emergency exit signs throughout Laundry Building, to improve occupant egress identification and life safety. | - | Market Research | 11/06/2026 |
| - | Awarded | Open |
Additional Details
Solicitation Number
N6945026RDC24
Archive Date
Sep 23, 2027
Office Address
NAS JACKSONVILLE, FL, 32212-0030