GovChime
Notice ID: 13429637d43c4161a53c8039f48ceb25Special Notice

C--Architect-Engineering Services in support of the National Energy Technology Lab

Archived on March 29, 2022. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
5:30 PM UTC−05:00
Posted
January 20, 2022
Notice type
Special Notice
NAICS
541330: Engineering Services
Agency
Department of Energy

Notice details

Office
NATIONAL ENERGY TECHNOLOGY LABORATORY
Last updated
Sep 9, 2025

Identifiers

Solicitation number
89243322RFE000067
Notice ID
13429637d43c4161a53c8039f48ceb25

Description

Architect-Engineering Services in support of the National Energy Technology Laboratory - Amendment 001 to provide contractor Questions and Responses and to provide revised synopsis language. ALL INFORMATION NEEDED FOR INTERESTED PARTIES TO SUBMIT A STANDARD FORM (SF) 330, ARCHITECT- ENGINEER QUALIFICATIONS IS CONTAINED HEREIN. THERE IS NO SEPARATE SOLICITATION PACKAGE TO DOWNLOAD. FEDERAL ACQUISITION REGULATION (FAR) PART 36.6 (THE SELECTION OF ARCHITECTS & ENGINEERS STATUTE) SELECTION PROCEDURES APPLY. Architect/Engineer (A/E) services in support of the Department of Energy (DOE) National Energy Technology Laboratory (NETL) are required for a firm-fixed-price Indefinite Delivery, Indefinite Quantity (IDIQ) contract for various types of A/E tasks related to construction projects and renovation or modification of existing facilities. The task orders issued under this IDIQ may include: Feasibility and Engineering Studies; Preliminary Design Services; Detailed Design Services; Construction Inspection Services; Energy and Environmental Management Activities; Value Engineering Activities; Risk Assessment; and Commissioning/Decommissioning. A strong multi-discipline team is required. This team can be comprised of a prime and subcontractors. Only Offerors who can provide the full range of services identified above should respond. The DOE NETL has research facilities in Pittsburgh, Pennsylvania; Morgantown, West Virginia; and Albany, Oregon. In addition, services on an as needed basis may be provided to other DOE off-site facilities for selected NETL supported projects. The principal places of performance will be at the Pittsburgh, Pennsylvania; Morgantown, West Virginia; and Albany, Oregon locations. The period of performance for the resultant contract shall include a two-year base period, and a three-year option period for a maximum of five-years. The maximum contract value may not exceed an aggregate total of $10,000,000.00 over the five-year period. The minimum guarantee for the IDIQ contract shall be $100,000.00 for the life of the contract. Task Orders may be issued between the amounts of $2,500.00 and $2,500,000.00. Multiple task orders may be awarded with similar completion schedules and overlapping delivery dates. The North American Industry Classification Systems (NAICS) Codes for this procurement are 541330, and the annual small business size standard is $16.5M. This procurement is a 100% SMALL BUSINESS SET-ASIDE. Small businesses may team together or with large businesses, and be eligible for award of a set-aside contract, as prescribed by the Small Business Administration guidelines. The Government may award one or more contracts from this public announcement, but anticipates a single award. The resulting contract(s) shall include the clause FAR 52.217-8, Option to Extend Services. Services may be accomplished in the firm's operating office with the exception of field/subsurface investigations and surveys as required at the specific task order project sites. Limited office space at the NETL facilities may be provided if space is available. Task orders are primarily for the preparation of detailed drawings and specifications, calculations, studies and cost estimates used by the Government for issuance of construction solicitations or for construction support/inspection services. Criterion 1 - Professional qualifications necessary for satisfactory performance of required services (1) Professional qualifications/resumes for key disciplines (i.e. to include, but not be limited to the Business Manager, Project Manager, Architect/Lead Designer, Lead Inspector, Structural Engineer, etc.) will be evaluated on the years and type of experience, level of education, types of degrees, professional certifications and licenses held; and (2) The types and number of projects the firms (or design team members) have worked together over the past five (5) years. Criterion 2 - Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials (1) Specialized experience and technical competence will be evaluated based on the design team members knowledge, both individually and collectively as a team, in Facility & Plant Engineering Design High Performance Sustainable Building Design Historic Preservation Evaluations Information and Communication Technology Modeling Software Construction Inspection Services Siting Studies and Engineering Studies New Construction and Renovations. (2) Firms (or design team members) will also be evaluated on their experience at incorporating sustainability principles into designs and evaluations, descriptions of waste reduction techniques and energy efficiency in facilities designed by the team, as well as familiarity with use of recovered materials on construction contracts per FAR 52.223-9. Criterion 3 - Capacity to accomplish the work in the required time (1) The volume, type, and dollar amount of the firm and design team members to accomplish multiple, large and small projects simultaneously, at different locations, within required timeframes, accomplished in either the public or private sector over the last five (5) years; and (2) The number of and types of employees (prime and subcontractor), including the availability of additional competent, regular employees for support of projects, and the depth and size of the organization so that any necessary expansion or acceleration of project workload can be handled adequately will be evaluated. Criterion 4 - Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules (1) The Government will evaluate the firms past performance and any subcontractors to determine the degree to which it demonstrates the likelihood it can successfully perform the requirements of the work here in. To be considered recent past performance the contract shall either be currently active or completed within the past five years of the closing date of this synopsis. In the case of a joint venture, LLC, or other team arrangement formed for the purpose of competing for this contract, the Government will evaluate relevant past performance of the entities that comprise the newly formed entity. Relevant past performance includes current or past contracts similar in size (dollar value), scope (type and nature of work), and complexity (duration, and/or risk) to the work described in the herein. The Government will use information either furnished by the Offeror and reference(s) and/or information obtained from other independent data sources in evaluating relevant past performance. For firms without a record of relevant past performance or for whom relevant past performance information is not available, the firm will not be evaluated favorably or unfavorably. Criterion 5 ( Acceptable / Unacceptable ) - Location in the general geographical area of the project and knowledge of the locality of the project. (1) The geographic location of the operating office shall be located in one of the following counties: MARYLAND: Allegany and Garrett; OHIO: Belmont and Monroe; PENNSYLVANIA: Allegheny, Armstrong, Beaver, Butler, Fayette, Greene, Indiana, Lawrence, Washington, and Westmoreland; and WEST VIRGINIA: Barbour, Brooke, Doddridge, Hancock, Harrison, Marion, Marshall, Monongalia, Ohio, Preston, Taylor, Tucker, Tyler, and Wetzel. (2) The offeror must demonstrate knowledge of OREGON, PENNSYLVANIA, and WEST VIRGINIA code and geographic requirements for designs and evaluations. Examples of demonstrated knowledge may include state licenses or projects completed within these states. The relative importance of the Technical Proposal Criteria is as follows: Criterion 1 and Criterion 2 are of equal importance, and when combined are of more important than Criterion 3 and Criterion 4 when combined. Criterion 3 and Criterion 4 are of equal importance and are more important than Criteria 5. The individual elements that comprise criteria 1, 2, 3, 4, and 5 are not listed in order of importance and will not be individually weighted, but rather will be considered as a whole in developing an overall rating for each criterion. Prospective offerors shall submit their SF 330 -- Architect-Engineer Qualifications Parts I and II in response to the request for qualifications. The SF 330's shall ensure that sufficient detail is provided to highlight the breadth and depth of the firm's experience in each of the evaluation areas. The A/E must demonstrate their and each key personnels qualifications with respect to the published evaluation criteria for all services. SUBMISSION REQUIREMENTS: The Department of Energys (DOE), National Energy Technology Laboratory (NETL) is using the FedConnect web portal (found at https://www.fedconnect.net) to disseminate the synopsis, receive questions, and accept responses for this requirement. ONLY RESPONSES SUBMITTED THROUGH FEDCONNECT WILL BE CONSIDERED FOR AWARD. To register, please visit the FedConnect web portal at https://www.fedconnect.net, and click on the link: Click here to register . Please note that before you can register in FedConnect, you will need a DUNS (http://fedgov.dnb.com/webform) and a System for Award Management (SAM) account (www.sam.gov). You are encouraged to register as soon as possible and should allow at least 14 days to complete these registrations. To find this synopsis, click on Search Public Opportunities and search by the Synopsis Number, 89243322RFE000067. Please bookmark this page and check it frequently for updates to this requirement. It is highly recommended that once you access the opportunity that you request to be alerted for amendments, messages, and any e-mail alerts associated with this requirement. To do so, you will need to click on the Register to Receive Notifications button under What do I do now? If someone from your company has already registered interest for this opportunity, the Register to Receive Notifications button will not display. Instead, you will have the option to join the response team by clicking the Join the Team button within the Response Team section. All questions regarding the content of this synopsis must be submitted electronically via FedConnect. You must register with FedConnect to respond as an interested party to submit questions, and to view responses to questions. Questions and answers will also be posted to the electronic reading room available at the following Web address http://netl.doe.gov/business/site-support. Questions will not be answered over the phone. The Contracting Officer must receive questions regarding the RFP via FedConnect no later than January 18, 2022 by 5:30 PM Eastern Local Tim. The Government reserves the right to not respond to any questions received after this timeframe. Please note - FedConnect is owned and operated by Compusearch Software Systems Inc., not by the Department of Energy and DOE does not provide help desk assistance for FedConnect. For assistance with FedConnect, please contact FedConnect directly: By e-mail: support@FedConnect.net By phone: 1-800-899-6665 (8:00 a.m. to 8:00 p.m., Eastern Local Time, except Federal holidays). Interested A/E firms having the capabilities to perform this work shall submit their response in accordance with the Instruction contained herein. Responses shall only be accepted through FedConnect and must be received no later than January 28, 2022 by 5:30 PM Eastern Local Time. No other notification will be made. Solicitation packages are not provided for A-E contracts. This is not a request for proposals. All responsible small business sources may submit the required SF 330 which will be considered by the agency. Electronic files of a large size may take a considerable amount of time to upload. It is your responsibility to allow an adequate amount of time for your proposal submission. You are strongly encouraged to submit your response at least 24 hours before the specified deadline in order to have time to resolve any transmission problems. RESPONSES THAT HAVE A FEDCONNECT DATE/TIME STAMP LATER THAN THE IDENTIFIED DEADLINE WILL BE CONSIDERED LATE AND WILL NOT BE REVIEWED OR CONSIDERED FOR AWARD. The Offeror shall be notified that their proposal was determined as being submitted late and was not further evaluated. It is the responsibility of the interested A/E firm, prior to the response due date and time, to verify successful transmission. Interested Architect-Engineer firms must submit the completed SF330 (03/2013) Part I and II for the prime firm and all consultants/subcontracts. The SF330 shall not exceed 50 single pages (5 pages if double sided). All pages shall be single spaced, using 12 point font, 1 margins, and when printed will fit on size 8 by 11 paper. The 12 point font is mandatory to ensure readability of the response and is intended for the response body text. It is not the Governments intent to require 12 point font size in headers/footers and/or to require interested firms to redo their graphics or tables to conform to this font size (where applicable). However, readability is at the risk of the interested firm and graphics/tables with less than 12 point font may not be considered in evaluation of the responses if they are not legible and clear to the evaluator. The page limits identified above do not apply to the cover pages, table of contents, glossary(ies), list of acronyms, or cross reference matrix(es). Response pages that exceed the identified page limitation listed above shall not be evaluated and will be removed from the end of the respective file (end of the section counting towards the page limitation; i.e. items excluded from the page limitation such as a glossary appearing at the end of the file will not be removed, only those pages that count towards the page count and that exceed the authorized limit shall be removed). The most highly qualified firm(s) may be required to provide in-person presentations prior to final selection and will be advised accordingly.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:89243322RFE000067
  1. 4×
    Special NoticeCurrentDec 9, 2021

    C--Architect-Engineering Services in support of the National Energy Technology Lab

    Notice 13429637d43c4161a53c8039f48ceb25 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Task Order is for Title III (Post Approved for Construction) Services for Task Nos. BM-MM-674C, BM-OM-2368, and BM-OM-2389 - Site Building Upgrades - Roof Replacements Buildings 242, 210, 244
78%
AwardedOpen
Task Order for Task No. WH-MM-2254, Raw Water Intake Structure Piping System Upgrades, Title I Preliminary and Title II Definitive Services
78%
AwardedOpen
This SOURCES SOUGHT ANNOUNCEMENT is a Market Survey for written information only. This is not a solicitation announcement for proposals and no contract will be awarded from this announcement. No reimbursement will be made for any costs associated with providing information in response to this announcement or any follow-up information requests. There is no bid package or solicitation. The Naval Facilities Engineering Command Engineering and Expeditionary Warfare Center (NAVFAC EXWC), Port Hueneme, CA is conducting a market survey and seeking sources for an Indefinite Delivery Indefinite Quantity (IDIQ), Firm-Fixed-Price (FFP) Single Award Contract; Architectural and Engineering firms that are capable of performing architect-engineer and design services for Energy Efficiency projects and services to shore facilities and utility systems at various locations, worldwide. The architect-engineer and engineering services may require expertise in installation and facility energy, water, and utility systems, with supporting architectural, mechanical, electrical, civil, structural, and environmental discipline as it pertains to Department of War (DoW) utility systems and energy consuming systems within the naval shore infrastructure. This is a follow-on requirement to contract N39430-23-D-4051, previously awarded to CH2M Hill Clark Nexsen Energy Partners JV. Award is anticipated to be made by June 2028. Security Requirements: Task Orders (TOs) issued under this contract may require performance at locations with security protocols more restrictive than the baseline contract requirements. For those locations, additional personnel information may be required before site access will be authorized for the team members assigned to the TO. The purpose of thus sources sought synopsis is to obtain additional information from interested/qualified sources. The applicable NAICS code is 541330 Engineering Services, with a size standard of $25.5M. The applicable Product Service Code is C219 Architect and Engineering – General: Other. Firms should also list whether it has a facilities clearance, and if not, would be able and willing to obtain a facilities clearance. Comments on the SAES are welcome. Response can be emailed to the contract specialize and contracting officer. At a minimum, provide the following information in your submittal: 1. Name and address of company and contact information/point of contact. 2. CAGE code and Unique Entity ID (UEI): 3. A brief statement of qualifications (not to exceed seven (7) total pages) to include experience relative to this procurement, or any other information that clearly demonstrates your capabilities, expertise and experience to perform the requirements listed in the attached Statement of Architect-Engineering Services (SAES). General marketing material may be included but must fall within the seven (7) page submittal requirement. Firms should provide the approximate number of personnel that are available to perform the work required and the size status in comparison to the NAICS code. 4. Statement as to small business program size status to the above NAICS Code and identification of any existing contract vehicles currently in place which may be used and fit the proposed contract scope. 5. Possible teaming arrangements: If you are responding as a prime contractor, provide anticipated subcontractors and their business size under the identified NAICS code. If you are responding as any other business or teaming entity, please identify the entity and the business size under the NAICS code, if known (e.g., Partnership, Joint Venture, LLC). This sources sought synopsis does not constitute a Request for Quotation (RFQ), Request for Proposal (RFP), or an Invitation for Bid (IFB), and is not to be considered as a commitment by the Government for any purpose other than market research, nor does issuance restrict the Governments acquisition approach. Respondents will not be notified of the results of the evaluation. The Government recognizes that proprietary data may be a part of your submittal. If so, clearly mark such restricted or proprietary data and present it as an addendum to the non-restricted/non-proprietary information. All submittals received will be reviewed for informational purposes. The Government reserves the right to independently verify all information submitted. Notifications of interest must be submitted in writing via email; phone calls will not be accepted. Notifications that do not address all the required information will not be considered. Interested parties should respond as soon as possible but no later than 1200 (Noon) Pacific Standard Time 03 December 2026. Responses to this Sources Sought Notice shall be emailed to the following points of contact: Contract Specialist Emily Rummell at emily.r.rummell.civ@us.navy.mil Contracting Officer Anthony Gonzales at anthony.j.gonzales104.civ@us.navy.mil
75%
Market Research12/03/2026
CONTRACT INFORMATION: This contract is being procured in accordance with the Selection of Architect Engineers Act, the provisions outlined in FAR Subpart 36.6 and the procedures provided in Engineer Pamphlet (EP) 715-1-7, section 3-16. Architect-Engineers (A-E) will be selected for negotiations based on demonstrated competence and qualifications for the type of professional services required. Work will be performed for the Corps of Engineers and its customers to include other Government agencies, and State and local entities. Orders may only be issued for Flood Control Dam and Levee work. Work will predominantly occur within the boundaries of the continental United States and its territories though limited work may potentially occur outside the continental United States when such work is assigned to the U.S. Army Corps of Engineers (USACE). Architect-Engineering services are required for diverse types of Flood Control Dam and Levee Safety Civil Works and MILCON support projects assigned to or by the Dam Safety Modification Center (DSMC). The contract will also provide capacity within the USACE Flood Control Dam and Levee Safety community requesting Architect-Engineering assistance through the Dam Safety Modification Center. A minimum of (3) firm-fixed price indefinite delivery contracts will be negotiated and awarded with a base period of one year and four option periods, one year each. The award amount will not exceed $250,000,000.00 combined capacity over the life of the contracts and work will be issued by negotiated firm-fixed price task orders with the most highly qualified in the pool selected via the Task Order Requirements Notice Process. Task Orders may be awarded between $2,500 and $120,000,000 in value. The contracts are expected to be awarded in July 2026. North American Industrial Classification System code is 541330, which has a size standard of $25.5 million in average annual receipts. This announcement is open to all businesses regardless of size. Large businesses must comply with FAR clause 52.219-9 (DEVIATION 2018-O00018) regarding the requirement for a subcontracting plan on the part of work it intends to subcontract; this is only required by the most highly qualified A-Es and is not part of the submittal for this synopsis. The A-Es found most highly qualified will be required to submit a Small Business Subcontracting Plan meeting the statutory small business limits of 23% overall, 5% small disadvantaged (including 8(a)), 5% woman owned and 3% each for Service-Disabled Veteran-Owned Small Business, and HUBZone businesses prior to award. The A-Es corporate Quality Control Plan is required with this submittal and will be evaluated as outlined in factor E. Each task order with site work will require a Site-Specific Safety and Health Plan and all require an individual task order specific Quality Control plan. To be eligible for contract award, each A-E must be registered in the System Award Management (SAM). Register via the SAM website at https://www.sam.gov/portal/public/SAM. Multiple contracts are being awarded under this synopsis, at least the three most highly qualified firms will each receive a Request for Proposal to allow development and submission of a price proposal. Task Orders will be awarded in accordance with the Selection of Architect Engineers Act guidance to ensure fair distribution of awards using the Task Order Requirements Notice procedures to the most highly qualified out of the pool of awarded contractors. PROJECT INFORMATION: The A-E services to be provided under this contract will be to provide Engineering Services for Flood Control Dam and Levee Safety efforts nationally. The A-E services will be multidisciplinary (see paragraph on Specialized Experience and Technical Competence below) in nature to support our mission to plan, design, construct, oversee construction, modify, operate, and control flood control reservoirs, dams, and levees. The A-E shall provide the appropriate personnel, materials, equipment, management, quality, and cost controls to perform all phases of engineering, and architectural services to include, but not limited to, planning studies; engineering investigations; risk assessments; designs; reports; construction plans and specifications; preliminary cost estimates; general construction and engineering type surveys and related services; Computer-Aided Design and Drafting (CADD); and construction consultation and inspection/quality assurance including engineering during construction. Work shall be accomplished in full compliance with established USACE manuals, policies, standards and practices and other professional practices and standards as necessitated by project conditions or job requirement. CADD information shall conform to paragraph (E) below. Capability for scanning hard copy into the CADD and 3D design system is also required. Work may require using the metric system. All work shall be prepared to be compatible with MS Office 365, and all specifications shall use SPECSINTACT format. Services shall also include any or all of the following based on need: Site characterization studies, Engineering evaluations and analyses in support of hydrologic (e.g. Inflow Design Flood) and seismic loading, consequence studies, Dam and Levee screenings, feasibility studies, preliminary and/or final designs, value engineering, constructability reviews, preparation of construction plans and specifications, or other analyses or studies related to the dam and levee safety programs. Services will be required to evaluate flood control dams and levee appurtenances including bridges, gates, spillways, pumping stations and other appurtenant structures attached to dams and levees as necessary to characterize the project. Earth embankment and foundation seepage analyses, inspection, assessment and design of concrete hydraulic structures and hydraulic steel structures associated with dam and levee safety projects. The A-E will be required to provide dam and levee safety experts to participate in highly complex dam and levee safety risk based Independent Expert Peer Reviews (IEPR), Expert Opinion Elicitations (EOE), for consultation, review of in-progress dam and levee safety design and construction activities, completed dam and levee safety construction, Risk Assessment and Analyses, Potential Failure Modes Analysis (PFMA), and numerical modeling of features associated with dam and levee safety projects. SELECTION CRITERIA: The selection criteria for this particular contract are listed below in descending order of importance. Criteria (i) through (vi) are primary. Criteria (vii) and (viii) are secondary and will only be used as a tiebreaker among firms that are essentially technically equal. i. Specialized Experience and Technical Competence: Firms must demonstrate specialized experience allowing objective evaluation and ranking of A-E capabilities on the following criteria/elements, which are listed in descending order of importance. For the proposed team, provide a maximum of ten (10) specific, completed projects that best illustrate overall team experience. Projects submitted shall have been completed as the prime A-E and be within the past five (5) years from the date qualifications submittals are due. Include a brief narrative for each project. Discuss conformance to scope, adherence to performance schedules, limiting changes, and delivering a product that satisfies the requirements. The A-E must only describe its exact efforts on the project and not appear to have made more effort than it did and be specific about firms effort. Dam Safety Design and Analysis to include experience with Risk Assessments, Issue Evaluation Studies, Dam Safety Modification Studies, Dam Modification Alternatives Development and Evaluation, Design Documentation Reports, Rehabilitation Reports, Plans and Specifications, Engineering Support During Construction, Geotechnical studies, Hydrologic and Hydraulic studies to include Computational Fluid Dynamics, Inflow Design Flood modeling, sediment transport modeling, scour evaluations and modeling, and cavitation assessments and modeling. Flood Damage Reduction Engineering to include experience with Planning and Design of floodwalls, levees and appurtenant structures, Design Documentation Reports, Rehabilitation Reports, Hydrologic and Hydraulic Studies, Plans and Specifications, Engineering Support during Construction. Engineering during construction and construction project evaluation of work in progress to report to the USACE work of others meeting contract requirements. Civil Engineering to include experience in civil site layout (preparation of applications for NPDES, as well as, construction permits, performing civil site layout to derive a reasonable and logical sequence of construction activities).Other Engineering, Architectural and Planning Services in support of Flood Control Dam and Levee Safety (each of equal importance) to include: Hydrologic and Hydraulic Studies Structural Analysis and Design Geotechnical and Engineering Geology Analysis and Design Electrical/Mechanical Design and Analysis Design of Sanitary and Water Projects Design, Inspection and Assessment of Bridges Roadway Design and Analysis Cost development of designs Scheduling of work ii. Professional Qualifications: The evaluation of professional qualifications will consider relevant experience, education, training, professional registration, organizational certifications, and longevity with the firm. The firm should indicate professional registrations/licenses, certifications from commercial organizations, professional recognition, professional associations, advanced training, and specific work experience of key personnel. The firm must staff the necessary Registered/Licensed Engineers, Geologists, Scientists, Architects and Surveyors having professional qualifications and specialized experience to perform and/or oversee that all work is accomplished as required by law and professional engineering architectural and surveying practices. Firms will be ranked on the above qualified registered professional personnel in the following key disciplines: Disciplines in the following group (Group A) are of equal importance: Structural Engineers, Geotechnical Engineers, Geologists, Hydraulic Engineers, Civil Engineers, Mechanical Engineers, Cost Engineers, and Electrical Engineers.Disciplines in the following group (Group B) are also of equal importance but are of lesser importance than the previous group (Group A): Specification Writers, Cost Engineers, Estimators, Engineering Technicians (Draftsmen/CADD Operators/GIS), Sanitary Waste Engineers, Planners, Architects, Professional Surveyors, Environmental Engineers, Environmental Geologists, Biologists (Ecologist), Safety Professionals, Hydrogeomorphologists, Industrial Hygienists and Construction Inspectors/Quality Assurance. Personnel proposed for Dam Safety Design and Analysis shall be shown in the Levels of Experience listed below. Provide appropriate documentation to justify their experience level. Level 1 experience includes five to ten (5-10) years of conventional engineering experience for dam/levee safety planning, engineering, design and/or construction in structural, geotechnical, engineering geology, hydraulic, civil, electrical, or mechanical engineering. Level 2 experience includes ten to fifteen (10-15) years of conventional engineering experience in dam/levee safety, and at least 5 years of risk-based/risk-informed engineering experience in dams and levee systems. Experience must include all experience within Level 1, plus participation on risk analysis teams for dam and levee systems, facilitation or participation in potential failure mode analysis (PFMA), or estimation of conditional probabilities of failure for static, hydrologic, and seismic failure modes, and estimating loss of life and economic consequences. Level 3 experience includes more than fifteen (15+) years of conventional engineering experience in dam/levee safety, and at least 5 years of risk-based/risk-informed engineering experience in dams and levee systems. Experience must include all experience within Levels 1 and 2, plus leading risk analysis teams, leading and/or participating in Expert Opinion Elicitations, and constructing event trees or using risk-based models to estimate risks for dam and levee projects. Experience conducting external peer review, quality control review, and consistency of decision and action review of Risk Analysis Reports and corrective action studies for dam and levee modifications is required. The criteria will include a review of projects submitted to determine relevant experience for both personnel and the firm, as well as Quality Management of engineering products. iii. Capacity: The PDT divided the NTE amount of $249,500,000.00 by the five-year period to arrive at the $49,900,000.00 capacity for the firm to perform within a one-year period in a satisfactory and efficient manner. The evaluation will consider the availability of an adequate number of personnel in key disciplines. The firm should have one point of contact for this contract and demonstrate past/projected-working relationships with subcontractors. Subcontracting with firms with specialized experienced areas is encouraged. Include an organization chart of the key personnel assigned to the contract. Firms should demonstrate strong ability to provide comprehensive program and project management for complex work; strong ability to provide comprehensive complex technical support; ability to provide necessary personnel for expedited, complex and unexpected work; ability to initiate, manage and complete multiple concurrent task orders; ability to meet unforeseen schedule changes and maintain delivery of a quality product on a timely schedule. iv. Past Performance: Past Performance during the past 5 years from the date the synopsis is posted to SAM.gov on similar contracts with respect to cost control, quality of work, ability to work independently and compliance with performance schedules as determined from Contractor Performance Assessment Reporting System (CPARS), FAPIIS data in SAM.gov, and other sources. However, any credible, documented evaluations may be considered, but the government is not required to seek other information on the past performance of a firm if none is available from CPARS. Relevant information to provide includes the following: Similar or equal work in terms of complexity in scope and size. Key personnel, offices, and subcontractors to be utilized on this contract. Firms role in the contract if a team such as a joint venture or prime-subcontractor relationship. Each A-Es past performance will be evaluated individually as well as in a team. The most recent projects will be given preference as they are indicative of current knowledge and abilities. Trends in performance as identified in PPIRS and FAPIIS. Credibility and detail in firms past performance report. Formal federal evaluations will be given more weight. High ratings on former DoD A-E contracts will be given a higher rating. v. Quality Management System: The evaluation will consider the firms Quality Management System. Firms must describe their quality control and quality assurance procedures with any subcontracts and procedures for continual improvement and ensuring customer satisfaction. State any experience with the International Standards Organization (ISO) 9001 standard and the DrChecks automated comment and response system. vi. CADD and Office Automation: All drawings and exhibits for design work, surveying work, drawings, maps, and details to be provided under this contract shall be accomplished and developed using computer-aided design (CAD) software and procedures conforming to the following criteria and most current versions of Target Software: National CAD Standard A/E/C CAD Standard Bentley ProjectWise most current version Autodesk AutoCAD Autodesk Revit Autodesk Civil 3DAutodesk Map 3DAutodesk Inventor Autodesk InfraWorks Autodesk Navisworks Autodesk ReCap Autodesk 3ds Max Bentley ProjectWise InterPlot Server and Client Bentley Open Ground Cloud Windows 11 operating system Microsoft Office Suite 365Adobe Acrobat Professional7z or compatible zip program Micro-Computer Aided Cost Estimating System II (MCACES)Bentley Products Legacy software may be required to convert or utilize documents. Consideration will be given to offerors that indicate compatibility with the above CAD standards, but preference will be given to offerors that demonstrate experience with the above standards. vii. Small Business Participation: SB and SDB Participation: The extent of participation of small businesses (including women-owned, HUBZone, small disadvantaged and service-disabled veteran-owned businesses) measured as a percentage of the total anticipated contracted effort, regardless of whether the small business is a prime contractor, subcontractor, or joint venture partner. viii. Equitable Distribution of DOD Contracts: Volume of DoD A-E contract awards in the last 12-months, with the objective of effecting an equitable distribution of DoD A-E contracts among qualified firms, including Small Business and Small Disadvantaged Business. SUBMISSION REQUIREMENTS: ALL RESPONSES TO THIS REQUIREMENT SHOULD BE SUBMITTED ELECTRONICALLY. Offerors shall submit SF330 Part I and Part II through the PIEE Solicitation Module at https://piee.eb.mil/ and reference the Solicitation number, W9123726RA007. Electronic submissions shall be maximum 2-pages per individual resumes and maximum 4-pages per project information, front-only, and 12-point, Times New Roman font except where mandated fillable forms require smaller fonts. Not to exceed 200 pages total (past performance is not included in page count). No paper copies, CD, DVD, thumb drives, email, or facsimile will be accepted. Electronic submissions must be received to the Government NLT, 5:00 PM Eastern Time on June 17, 2026. Electronic submissions shall be based on 8.5 x11 page size. The only exceptions are Organization Chart or Experience/Qualification matrix which may be based on a 11x17 page size. Personnel resumes shall be limited to two electronic pages (one page front and back equivalent) per person. Any information on a resume beyond the two electronic pages (one page front and back equivalent) will not be considered. Include the A-Es Cage or UEI number. Solicitation packages are not provided, and no additional project information will be given to A-Es during the announcement period. This is not a Request for Proposal. The POC for this procurement is Lillie V. Bodie, lillie.v.bodie@usace.army.mil.
69%
Combined Synopsis06/17/2026
CONTRACT INFORMATION: This contract is being procured in accordance with the Selection of Architect Engineers Act, the provisions outlined in FAR Subpart 36.6 and the procedures provided in Engineer Pamphlet (EP) 715-1-7, section 3-16. Architect-Engineers (A-E) will be selected for negotiations based on demonstrated competence and qualifications for the type of professional services required. Work will be performed for the Corps of Engineers and its customers to include other Government agencies, and State and local entities. Orders may only be issued for Flood Control Dam and Levee work. Work will predominantly occur within the boundaries of the continental United States and its territories though limited work may potentially occur outside the continental United States when such work is assigned to the U.S. Army Corps of Engineers (USACE). Architect-Engineering services are required for diverse types of Flood Control Dam and Levee Safety Civil Works and MILCON support projects assigned to or by the Dam Safety Modification Center (DSMC). The contract will also provide capacity within the USACE Flood Control Dam and Levee Safety community requesting Architect-Engineering assistance through the Dam Safety Modification Center. A minimum of (3) firm-fixed price indefinite delivery contracts will be negotiated and awarded with a base period of one year and four option periods, one year each. The award amount will not exceed $250,000,000.00 combined capacity over the life of the contracts and work will be issued by negotiated firm-fixed price task orders with the most highly qualified in the pool selected via the Task Order Requirements Notice Process. Task Orders may be awarded between $2,500 and $120,000,000 in value. The contracts are expected to be awarded in July 2026. North American Industrial Classification System code is 541330, which has a size standard of $25.5 million in average annual receipts. This announcement is open to all businesses regardless of size. Large businesses must comply with FAR clause 52.219-9 (DEVIATION 2018-O00018) regarding the requirement for a subcontracting plan on the part of work it intends to subcontract; this is only required by the most highly qualified A-Es and is not part of the submittal for this synopsis. The A-Es found most highly qualified will be required to submit a Small Business Subcontracting Plan meeting the statutory small business limits of 23% overall, 5% small disadvantaged (including 8(a)), 5% woman owned and 3% each for Service-Disabled Veteran-Owned Small Business, and HUBZone businesses prior to award. The A-E’s corporate Quality Control Plan is required with this submittal and will be evaluated as outlined in factor E. Each task order with site work will require a Site-Specific Safety and Health Plan and all require an individual task order specific Quality Control plan. To be eligible for contract award, each A-E must be registered in the System Award Management (SAM). Register via the SAM website at https://www.sam.gov/portal/public/SAM. Multiple contracts are being awarded under this synopsis, at least the three most highly qualified firms will each receive a Request for Proposal to allow development and submission of a price proposal. Task Orders will be awarded in accordance with the Selection of Architect Engineers Act guidance to ensure fair distribution of awards using the Task Order Requirements Notice procedures to the most highly qualified out of the pool of awarded contractors. PROJECT INFORMATION: The A-E services to be provided under this contract will be to provide Engineering Services for Flood Control Dam and Levee Safety efforts nationally. The A-E services will be multidisciplinary (see paragraph on Specialized Experience and Technical Competence below) in nature to support our mission to plan, design, construct, oversee construction, modify, operate, and control flood control reservoirs, dams, and levees. The A-E shall provide the appropriate personnel, materials, equipment, management, quality, and cost controls to perform all phases of engineering, and architectural services to include, but not limited to, planning studies; engineering investigations; risk assessments; designs; reports; construction plans and specifications; preliminary cost estimates; general construction and engineering type surveys and related services; Computer-Aided Design and Drafting (CADD); and construction consultation and inspection/quality assurance including engineering during construction. Work shall be accomplished in full compliance with established USACE manuals, policies, standards and practices and other professional practices and standards as necessitated by project conditions or job requirement. CADD information shall conform to paragraph (E) below. Capability for scanning hard copy into the CADD and 3D design system is also required. Work may require using the metric system. All work shall be prepared to be compatible with MS Office 365, and all specifications shall use SPECSINTACT format. Services shall also include any or all of the following based on need: Site characterization studies, Engineering evaluations and analyses in support of hydrologic (e.g. Inflow Design Flood) and seismic loading, consequence studies, Dam and Levee screenings, feasibility studies, preliminary and/or final designs, value engineering, constructability reviews, preparation of construction plans and specifications, or other analyses or studies related to the dam and levee safety programs. Services will be required to evaluate flood control dams and levee appurtenances including bridges, gates, spillways, pumping stations and other appurtenant structures attached to dams and levees as necessary to characterize the project. Earth embankment and foundation seepage analyses, inspection, assessment and design of concrete hydraulic structures and hydraulic steel structures associated with dam and levee safety projects. The A-E will be required to provide dam and levee safety experts to participate in highly complex dam and levee safety risk based Independent Expert Peer Reviews (IEPR), Expert Opinion Elicitations (EOE), for consultation, review of in-progress dam and levee safety design and construction activities, completed dam and levee safety construction, Risk Assessment and Analyses, Potential Failure Modes Analysis (PFMA), and numerical modeling of features associated with dam and levee safety projects. SELECTION CRITERIA: The selection criteria for this particular contract are listed below in descending order of importance. Criteria (i) through (vi) are primary. Criteria (vii) and (viii) are secondary and will only be used as a “tiebreaker” among firms that are essentially technically equal. Specialized Experience and Technical Competence: Firms must demonstrate specialized experience allowing objective evaluation and ranking of A-E capabilities on the following criteria/elements, which are listed in descending order of importance. For the proposed team, provide a maximum of ten (10) specific, completed projects that best illustrate overall team experience. Projects submitted shall have been completed as the prime A-E and be within the past five (5) years from the date qualifications submittals are due. Include a brief narrative for each project. Discuss conformance to scope, adherence to performance schedules, limiting changes, and delivering a product that satisfies the requirements. The A-E must only describe its exact efforts on the project and not appear to have made more effort than it did and be specific about firms’ effort. Dam Safety Design and Analysis to include experience with Risk Assessments, Issue Evaluation Studies, Dam Safety Modification Studies, Dam Modification Alternatives Development and Evaluation, Design Documentation Reports, Rehabilitation Reports, Plans and Specifications, Engineering Support During Construction, Geotechnical studies, Hydrologic and Hydraulic studies to include Computational Fluid Dynamics, Inflow Design Flood modeling, sediment transport modeling, scour evaluations and modeling, and cavitation assessments and modeling. Flood Damage Reduction Engineering to include experience with Planning and Design of floodwalls, levees and appurtenant structures, Design Documentation Reports, Rehabilitation Reports, Hydrologic and Hydraulic Studies, Plans and Specifications, Engineering Support during Construction. Engineering during construction and construction project evaluation of work in progress to report to the USACE work of others meeting contract requirements. Civil Engineering to include experience in civil site layout (preparation of applications for NPDES, as well as, construction permits, performing civil site layout to derive a reasonable and logical sequence of construction activities). Other Engineering, Architectural and Planning Services in support of Flood Control Dam and Levee Safety (each of equal importance) to include: Hydrologic and Hydraulic Studies Structural Analysis and Design Geotechnical and Engineering Geology Analysis and Design Electrical/Mechanical Design and Analysis Design of Sanitary and Water Projects Design, Inspection and Assessment of Bridges Roadway Design and Analysis Cost development of designs Scheduling of work Professional Qualifications: The evaluation of professional qualifications will consider relevant experience, education, training, professional registration, organizational certifications, and longevity with the firm. The firm should indicate professional registrations/licenses, certifications from commercial organizations, professional recognition, professional associations, advanced training, and specific work experience of key personnel. The firm must staff the necessary Registered/Licensed Engineers, Geologists, Scientists, Architects and Surveyors having professional qualifications and specialized experience to perform and/or oversee that all work is accomplished as required by law and professional engineering architectural and surveying practices. Firms will be ranked on the above qualified registered professional personnel in the following key disciplines: Disciplines in the following group (Group A) are of equal importance: Structural Engineers, Geotechnical Engineers, Geologists, Hydraulic Engineers, Civil Engineers, Mechanical Engineers, Cost Engineers, and Electrical Engineers. Disciplines in the following group (Group B) are also of equal importance but are of lesser importance than the previous group (Group A): Specification Writers, Cost Engineers, Estimators, Engineering Technicians (Draftsmen/CADD Operators/GIS), Sanitary Waste Engineers, Planners, Architects, Professional Surveyors, Environmental Engineers, Environmental Geologists, Biologists (Ecologist), Safety Professionals, Hydrogeomorphologists, Industrial Hygienists and Construction Inspectors/Quality Assurance. Personnel proposed for Dam Safety Design and Analysis shall be shown in the Levels of Experience listed below. Provide appropriate documentation to justify their experience level. Level 1 experience includes five to ten (5-10) years of conventional engineering experience for dam/levee safety planning, engineering, design and/or construction in structural, geotechnical, engineering geology, hydraulic, civil, electrical, or mechanical engineering. Level 2 experience includes ten to fifteen (10-15) years of conventional engineering experience in dam/levee safety, and at least 5 years of risk-based/risk-informed engineering experience in dams and levee systems. Experience must include all experience within Level 1, plus participation on risk analysis teams for dam and levee systems, facilitation or participation in potential failure mode analysis (PFMA), or estimation of conditional probabilities of failure for static, hydrologic, and seismic failure modes, and estimating loss of life and economic consequences. Level 3 experience includes more than fifteen (15+) years of conventional engineering experience in dam/levee safety, and at least 5 years of risk-based/risk-informed engineering experience in dams and levee systems. Experience must include all experience within Levels 1 and 2, plus leading risk analysis teams, leading and/or participating in Expert Opinion Elicitations, and constructing event trees or using risk-based models to estimate risks for dam and levee projects. Experience conducting external peer review, quality control review, and consistency of decision and action review of Risk Analysis Reports and corrective action studies for dam and levee modifications is required. The criteria will include a review of projects submitted to determine relevant experience for both personnel and the firm, as well as Quality Management of engineering products. Capacity: The PDT divided the NTE amount of $249,500,000.00 by the five-year period to arrive at the $49,900,000.00 capacity for the firm to perform within a one-year period in a satisfactory and efficient manner. The evaluation will consider the availability of an adequate number of personnel in key disciplines. The firm should have one point of contact for this contract and demonstrate past/projected-working relationships with subcontractors. Subcontracting with firms with specialized experienced areas is encouraged. Include an organization chart of the key personnel assigned to the contract. Firms should demonstrate strong ability to provide comprehensive program and project management for complex work; strong ability to provide comprehensive complex technical support; ability to provide necessary personnel for expedited, complex and unexpected work; ability to initiate, manage and complete multiple concurrent task orders; ability to meet unforeseen schedule changes and maintain delivery of a quality product on a timely schedule. Past Performance: Past Performance during the past 5 years from the date the synopsis is posted to SAM.gov on similar contracts with respect to cost control, quality of work, ability to work independently and compliance with performance schedules as determined from Contractor Performance Assessment Reporting System (CPARS), FAPIIS data in SAM.gov, and other sources. CPARS is the primary source of information on past performance. However, any credible, documented evaluations may be considered, but the government is not required to seek other information on the past performance of a firm if none is available from CPARS. Relevant information to provide includes the following: Similar or equal work in terms of complexity in scope and size. Key personnel, offices, and subcontractors to be utilized on this contract. Firm’s role in the contract if a team such as a joint venture or prime-subcontractor relationship. Each A-Es past performance will be evaluated individually as well as in a team. The most recent projects will be given preference as they are indicative of current knowledge and abilities. Trends in performance as identified in PPIRS and FAPIIS. Credibility and detail in firm’s past performance report. Formal federal evaluations will be given more weight. High ratings on former DoD A-E contracts will be given a higher rating. Quality Management System: The evaluation will consider the firm’s Quality Management System. Firms must describe their quality control and quality assurance procedures with any subcontracts and procedures for continual improvement and ensuring customer satisfaction. State any experience with the International Standards Organization (ISO) 9001 standard and the DrChecks automated comment and response system. CADD and Office Automation: All drawings and exhibits for design work, surveying work, drawings, maps, and details to be provided under this contract shall be accomplished and developed using computer-aided design (CAD) software and procedures conforming to the following criteria and most current versions of Target Software: National CAD Standard A/E/C CAD Standard Bentley ProjectWise most current version Autodesk AutoCAD Autodesk Revit Autodesk Civil 3D Autodesk Map 3D Autodesk Inventor Autodesk InfraWorks Autodesk Navisworks Autodesk ReCap Autodesk 3ds Max Bentley ProjectWise InterPlot Server and Client Bentley OpenGround Cloud Windows 11 operating system Microsoft Office Suite 365 Adobe Acrobat Professional 7z or compatible zip program Micro-Computer Aided Cost Estimating System II (MCACES) Bentley Products Legacy software may be required to convert or utilize documents. Consideration will be given to offerors that indicate compatibility with the above CAD standards, but preference will be given to offerors that demonstrate experience with the above standards. Small Business Participation: SB and SDB Participation: The extent of participation of small businesses (including women-owned, HUBZone, small disadvantaged and service-disabled veteran-owned businesses) measured as a percentage of the total anticipated contracted effort, regardless of whether the small business is a prime contractor, subcontractor, or joint venture partner. Equitable Distribution of DOD Contracts: Volume of DoD A-E contract awards in the last 12-months, with the objective of effecting an equitable distribution of DoD A-E contracts among qualified firms, including Small Business and Small Disadvantaged Business. SUBMISSION REQUIREMENTS: ALL RESPONSES TO THIS REQUIREMENT SHOULD BE SUBMITTED ELECTRONICALLY. Offerors shall submit SF330 Part I and Part II through the PIEE Solicitation Module at https://piee.eb.mil/ and reference the Solicitation number of W9123726RA007. Electronic submissions shall be maximum 2-pages per individual resumes and maximum 4-pages per project information, front-only, and 12-point, Times New Roman font except where mandated fillable forms require smaller fonts. Not to exceed 200 pages total (past performance is not included in page count). No paper copies, CD, DVD, thumb drives, email, or facsimile will be accepted. Electronic submissions must be received to the Government NLT, 5:00 PM Eastern Time on 12 June 2026. Electronic submissions shall be based on 8.5 x11 page size. The only exceptions are Organization Chart or Experience/Qualification matrix which may be based on a 11x17 page size. Personnel resumes shall be limited to two electronic pages (one page front and back equivalent) per person. Any information on a resume beyond the two electronic pages (one page front and back equivalent) will not be considered. Include the A-E's Cage or UEI number. Solicitation packages are not provided, and no additional project information will be given to A-Es during the announcement period. This is not a Request for Proposal. The POC for this procurement is Lillie V. Bodie, lillie.v.bodie@usace.army.mil. This contract is being procured in accordance with the Selection of Architect Engineers Act, the provisions outlined in FAR Subpart 36.6 and the procedures provided in Engineer Pamphlet (EP) 715-1-7, section 3-16. Architect-Engineers (A-E) will be selected for negotiations based on demonstrated competence and qualifications for the type of professional services required. Work will be performed for the Corps of Engineers and its customers to include other Government agencies, and State and local entities. Orders may only be issued for Flood Control Dam and Levee work. Work will predominantly occur within the boundaries of the continental United States and its territories though limited work may potentially occur outside the continental United States when such work is assigned to the U.S. Army Corps of Engineers (USACE). Architect-Engineering services are required for diverse types of Flood Control Dam and Levee Safety Civil Works and MILCON support projects assigned to or by the Dam Safety Modification Center (DSMC). The contract will also provide capacity within the USACE Flood Control Dam and Levee Safety community requesting Architect-Engineering assistance through the Dam Safety Modification Center. A minimum of (3) firm-fixed price indefinite delivery contracts will be negotiated and awarded with a base period of one year and four option periods, one year each. The award amount will not exceed $250,000,000.00 combined capacity over the life of the contracts and work will be issued by negotiated firm-fixed price task orders with the most highly qualified in the pool selected via the Task Order Requirements Notice Process. Task Orders may be awarded between $2,500 and $120,000,000 in value. The contracts are expected to be awarded in July 2026. North American Industrial Classification System code is 541330, which has a size standard of $25.5 million in average annual receipts. This announcement is open to all businesses regardless of size. Large businesses must comply with FAR clause 52.219-9 (DEVIATION 2018-O00018) regarding the requirement for a subcontracting plan on the part of work it intends to subcontract; this is only required by the most highly qualified A-Es and is not part of the submittal for this synopsis. The A-Es found most highly qualified will be required to submit a Small Business Subcontracting Plan meeting the statutory small business limits of 23% overall, 5% small disadvantaged (including 8(a)), 5% woman owned and 3% each for Service-Disabled Veteran-Owned Small Business, and HUBZone businesses prior to award. The A-E’s corporate Quality Control Plan is required with this submittal and will be evaluated as outlined in factor E. Each task order with site work will require a Site-Specific Safety and Health Plan and all require an individual task order specific Quality Control plan. To be eligible for contract award, each A-E must be registered in the System Award Management (SAM). Register via the SAM website at https://www.sam.gov/portal/public/SAM. Multiple contracts are being awarded under this synopsis, at least the three most highly qualified firms will each receive a Request for Proposal to allow development and submission of a price proposal. Task Orders will be awarded in accordance with the Selection of Architect Engineers Act guidance to ensure fair distribution of awards using the Task Order Requirements Notice procedures to the most highly qualified out of the pool of awarded contractors. PROJECT INFORMATION: The A-E services to be provided under this contract will be to provide Engineering Services for Flood Control Dam and Levee Safety efforts nationally. The A-E services will be multidisciplinary (see paragraph on Specialized Experience and Technical Competence below) in nature to support our mission to plan, design, construct, oversee construction, modify, operate, and control flood control reservoirs, dams, and levees. The A-E shall provide the appropriate personnel, materials, equipment, management, quality, and cost controls to perform all phases of engineering, and architectural services to include, but not limited to, planning studies; engineering investigations; risk assessments; designs; reports; construction plans and specifications; preliminary cost estimates; general construction and engineering type surveys and related services; Computer-Aided Design and Drafting (CADD); and construction consultation and inspection/quality assurance including engineering during construction. Work shall be accomplished in full compliance with established USACE manuals, policies, standards and practices and other professional practices and standards as necessitated by project conditions or job requirement. CADD information shall conform to paragraph (E) below. Capability for scanning hard copy into the CADD and 3D design system is also required. Work may require using the metric system. All work shall be prepared to be compatible with MS Office 365, and all specifications shall use SPECSINTACT format. Services shall also include any or all of the following based on need: Site characterization studies, Engineering evaluations and analyses in support of hydrologic (e.g. Inflow Design Flood) and seismic loading, consequence studies, Dam and Levee screenings, feasibility studies, preliminary and/or final designs, value engineering, constructability reviews, preparation of construction plans and specifications, or other analyses or studies related to the dam and levee safety programs. Services will be required to evaluate flood control dams and levee appurtenances including bridges, gates, spillways, pumping stations and other appurtenant structures attached to dams and levees as necessary to characterize the project. Earth embankment and foundation seepage analyses, inspection, assessment and design of concrete hydraulic structures and hydraulic steel structures associated with dam and levee safety projects. The A-E will be required to provide dam and levee safety experts to participate in highly complex dam and levee safety risk based Independent Expert Peer Reviews (IEPR), Expert Opinion Elicitations (EOE), for consultation, review of in-progress dam and levee safety design and construction activities, completed dam and levee safety construction, Risk Assessment and Analyses, Potential Failure Modes Analysis (PFMA), and numerical modeling of features associated with dam and levee safety projects. SELECTION CRITERIA: The selection criteria for this particular contract are listed below in descending order of importance. Criteria (i) through (vi) are primary. Criteria (vii) and (viii) are secondary and will only be used as a “tiebreaker” among firms that are essentially technically equal. Specialized Experience and Technical Competence: Firms must demonstrate specialized experience allowing objective evaluation and ranking of A-E capabilities on the following criteria/elements, which are listed in descending order of importance. For the proposed team, provide a maximum of ten (10) specific, completed projects that best illustrate overall team experience. Projects submitted shall have been completed as the prime A-E and be within the past five (5) years from the date qualifications submittals are due. Include a brief narrative for each project. Discuss conformance to scope, adherence to performance schedules, limiting changes, and delivering a product that satisfies the requirements. The A-E must only describe its exact efforts on the project and not appear to have made more effort than it did and be specific about firms’ effort. Dam Safety Design and Analysis to include experience with Risk Assessments, Issue Evaluation Studies, Dam Safety Modification Studies, Dam Modification Alternatives Development and Evaluation, Design Documentation Reports, Rehabilitation Reports, Plans and Specifications, Engineering Support During Construction, Geotechnical studies, Hydrologic and Hydraulic studies to include Computational Fluid Dynamics, Inflow Design Flood modeling, sediment transport modeling, scour evaluations and modeling, and cavitation assessments and modeling. Flood Damage Reduction Engineering to include experience with Planning and Design of floodwalls, levees and appurtenant structures, Design Documentation Reports, Rehabilitation Reports, Hydrologic and Hydraulic Studies, Plans and Specifications, Engineering Support during Construction. Engineering during construction and construction project evaluation of work in progress to report to the USACE work of others meeting contract requirements. Civil Engineering to include experience in civil site layout (preparation of applications for NPDES, as well as, construction permits, performing civil site layout to derive a reasonable and logical sequence of construction activities). Other Engineering, Architectural and Planning Services in support of Flood Control Dam and Levee Safety (each of equal importance) to include: Hydrologic and Hydraulic Studies Structural Analysis and Design Geotechnical and Engineering Geology Analysis and Design Electrical/Mechanical Design and Analysis Design of Sanitary and Water Projects Design, Inspection and Assessment of Bridges Roadway Design and Analysis Cost development of designs Scheduling of work Professional Qualifications: The evaluation of professional qualifications will consider relevant experience, education, training, professional registration, organizational certifications, and longevity with the firm. The firm should indicate professional registrations/licenses, certifications from commercial organizations, professional recognition, professional associations, advanced training, and specific work experience of key personnel. The firm must staff the necessary Registered/Licensed Engineers, Geologists, Scientists, Architects and Surveyors having professional qualifications and specialized experience to perform and/or oversee that all work is accomplished as required by law and professional engineering architectural and surveying practices. Firms will be ranked on the above qualified registered professional personnel in the following key disciplines: Disciplines in the following group (Group A) are of equal importance: Structural Engineers, Geotechnical Engineers, Geologists, Hydraulic Engineers, Civil Engineers, Mechanical Engineers, Cost Engineers, and Electrical Engineers. Disciplines in the following group (Group B) are also of equal importance but are of lesser importance than the previous group (Group A): Specification Writers, Cost Engineers, Estimators, Engineering Technicians (Draftsmen/CADD Operators/GIS), Sanitary Waste Engineers, Planners, Architects, Professional Surveyors, Environmental Engineers, Environmental Geologists, Biologists (Ecologist), Safety Professionals, Hydrogeomorphologists, Industrial Hygienists and Construction Inspectors/Quality Assurance. Personnel proposed for Dam Safety Design and Analysis shall be shown in the Levels of Experience listed below. Provide appropriate documentation to justify their experience level. Level 1 experience includes five to ten (5-10) years of conventional engineering experience for dam/levee safety planning, engineering, design and/or construction in structural, geotechnical, engineering geology, hydraulic, civil, electrical, or mechanical engineering. Level 2 experience includes ten to fifteen (10-15) years of conventional engineering experience in dam/levee safety, and at least 5 years of risk-based/risk-informed engineering experience in dams and levee systems. Experience must include all experience within Level 1, plus participation on risk analysis teams for dam and levee systems, facilitation or participation in potential failure mode analysis (PFMA), or estimation of conditional probabilities of failure for static, hydrologic, and seismic failure modes, and estimating loss of life and economic consequences. Level 3 experience includes more than fifteen (15+) years of conventional engineering experience in dam/levee safety, and at least 5 years of risk-based/risk-informed engineering experience in dams and levee systems. Experience must include all experience within Levels 1 and 2, plus leading risk analysis teams, leading and/or participating in Expert Opinion Elicitations, and constructing event trees or using risk-based models to estimate risks for dam and levee projects. Experience conducting external peer review, quality control review, and consistency of decision and action review of Risk Analysis Reports and corrective action studies for dam and levee modifications is required. The criteria will include a review of projects submitted to determine relevant experience for both personnel and the firm, as well as Quality Management of engineering products. Capacity: The PDT divided the NTE amount of $249,500,000.00 by the five-year period to arrive at the $49,900,000.00 capacity for the firm to perform within a one-year period in a satisfactory and efficient manner. The evaluation will consider the availability of an adequate number of personnel in key disciplines. The firm should have one point of contact for this contract and demonstrate past/projected-working relationships with subcontractors. Subcontracting with firms with specialized experienced areas is encouraged. Include an organization chart of the key personnel assigned to the contract. Firms should demonstrate strong ability to provide comprehensive program and project management for complex work; strong ability to provide comprehensive complex technical support; ability to provide necessary personnel for expedited, complex and unexpected work; ability to initiate, manage and complete multiple concurrent task orders; ability to meet unforeseen schedule changes and maintain delivery of a quality product on a timely schedule. Past Performance: Past Performance during the past 5 years from the date the synopsis is posted to SAM.gov on similar contracts with respect to cost control, quality of work, ability to work independently and compliance with performance schedules as determined from Past Performance Information Retrieval System (PPIRS), FAPIIS data in SAM.gov, and other sources. PPIRS is the primary source of information on past performance. However, any credible, documented evaluations may be considered, but the government is not required to seek other information on the past performance of a firm if none is available from PPIRS. Relevant information to provide includes the following: Similar or equal work in terms of complexity in scope and size. Key personnel, offices, and subcontractors to be utilized on this contract. Firm’s role in the contract if a team such as a joint venture or prime-subcontractor relationship. Each A-Es past performance will be evaluated individually as well as in a team. The most recent projects will be given preference as they are indicative of current knowledge and abilities. Trends in performance as identified in PPIRS and FAPIIS. Credibility and detail in firm’s past performance report. Formal federal evaluations will be given more weight. High ratings on former DoD A-E contracts will be given a higher rating. Quality Management System: The evaluation will consider the firm’s Quality Management System. Firms must describe their quality control and quality assurance procedures with any subcontracts and procedures for continual improvement and ensuring customer satisfaction. State any experience with the International Standards Organization (ISO) 9001 standard and the DrChecks automated comment and response system. CADD and Office Automation: All drawings and exhibits for design work, surveying work, drawings, maps, and details to be provided under this contract shall be accomplished and developed using computer-aided design (CAD) software and procedures conforming to the following criteria and most current versions of Target Software: National CAD Standard A/E/C CAD Standard Bentley ProjectWise most current version Autodesk AutoCAD Autodesk Revit Autodesk Civil 3D Autodesk Map 3D Autodesk Inventor Autodesk InfraWorks Autodesk Navisworks Autodesk ReCap Autodesk 3ds Max Bentley ProjectWise InterPlot Server and Client Bentley OpenGround Cloud Windows 11 operating system Microsoft Office Suite 365 Adobe Acrobat Professional 7z or compatible zip program Micro-Computer Aided Cost Estimating System II (MCACES) Bentley Products Legacy software may be required to convert or utilize documents. Consideration will be given to offerors that indicate compatibility with the above CAD standards, but preference will be given to offerors that demonstrate experience with the above standards. Small Business Participation: SB and SDB Participation: The extent of participation of small businesses (including women-owned, HUBZone, small disadvantaged and service-disabled veteran-owned businesses) measured as a percentage of the total anticipated contracted effort, regardless of whether the small business is a prime contractor, subcontractor, or joint venture partner. Equitable Distribution of DOD Contracts: Volume of DoD A-E contract awards in the last 12-months, with the objective of effecting an equitable distribution of DoD A-E contracts among qualified firms, including Small Business and Small Disadvantaged Business. SUBMISSION REQUIREMENTS: ALL RESPONSES TO THIS REQUIREMENT SHOULD BE SUBMITTED ELECTRONICALLY. Offerors shall submit SF330 Part I and Part II through the PIEE Solicitation Module at https://piee.eb.mil/ and reference the Solicitation number of W9123726RA007. Electronic submissions shall be maximum 2-pages per individual resumes and maximum 4-pages per project information, front-only, and 12-point, Times New Roman font except where mandated fillable forms require smaller fonts. Not to exceed 200 pages total (past performance is not included in page count). No paper copies, CD, DVD, thumb drives, email, or facsimile will be accepted. Electronic submissions must be received to the Government NLT, 5:00 PM Eastern Time on 12 June 2026. Electronic submissions shall be based on 8.5 x11 page size. The only exceptions are Organization Chart or Experience/Qualification matrix which may be based on a 11x17 page size. Personnel resumes shall be limited to two electronic pages (one page front and back equivalent) per person. Any information on a resume beyond the two electronic pages (one page front and back equivalent) will not be considered. Include the A-E's Cage or UEI number. Solicitation packages are not provided, and no additional project information will be given to A-Es during the announcement period. This is not a Request for Proposal. The POC for this procurement is Lillie V. Bodie, lillie.v.bodie@usace.army.mil.
69%
Pre-Solicitation06/12/2026

Additional Details

Solicitation Number

89243322RFE000067

Archive Date

Mar 29, 2022

Office Address

MORGANTOWN, WV, 26507