Notice ID: da3d5c0b44d5464e8202ef95a301973dAward NoticeAwardedArchived
A--Development of electromagnetic transmitter and receiver technology.
Awarded on September 17, 2026. Full description on SAM.gov.
Awarded tounder 89243326PFE001009 (source: SAM.gov award notice)• $598.0K
Overview
- Posted
- September 17, 2026
- Notice type
- Award Notice
- NAICS
- 541690: Other Scientific and Technical Consulting Services
- Agency
- Department of Energy
Notice details
- Office
- NATIONAL ENERGY TECHNOLOGY LABORATORY
- PSC
- AJ13: GENERAL SCIENCE & TECHNOLOGY R&D SVCS; GENERAL SCIENCE & TECHNOLOGY; EXPERIMENTAL DEVELOPMENT
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
- Award date
- Sep 17, 2026
- Award amount (SAM.gov award notice)
- $598.0K
Identifiers
- Solicitation number
- 89243326NFE000255
- Notice ID
- da3d5c0b44d5464e8202ef95a301973d
- Award number (PIID)
- 89243326PFE001009
Description
Development of electromagnetic transmitter and receiver technology.
Award Overview
Award Number
89243326PFE001009
Award Amount (SAM.gov award notice)
$598.0K
Award Date
Sep 17, 2026
Awardee
Awardee UEI
D4MBFWQ1NGW7
Awardee CAGE Code
42HX3
Awardee Address
1140 Applegate St Unit 1045, Philomath, OR 97370, UNITED STATES
Original Solicitation
Notice ID: da3d5c0b44d5464e8202ef95a301973d
Posted Date: Sep 17, 2026
Original Response Deadline: Not specified
Contacts
Contracting Officer
Primary Contact
Documents
No documents available.
Lifecycle
- 3Version 3Award NoticeArchivedCurrent
A--Development of electromagnetic transmitter and receiver technology.
Other notices for this solicitation
- Special NoticeRelated noticeAug 19, 2026
A--Notice of Intent to Sole Source for an electromagnetic transmitter to IoMT LLC.
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Louis A Johnson Medical Center seeks a contractor to provide industrial hygiene support, specifically quantitative respirator fit testing, for medical center employees. The contractor will supply all necessary fit testing equipment (such as TSI PortaCount machines), consumables, and Controlled Air Purifying Respirators (CAPRs) for personnel requiring alternatives to N95 respirators. Training for CAPRs and qualitative fit testing may also be required, depending on operational needs. | - | Combined Synopsis | 11/05/2026 |
The Department of Energy Office of Science requires a single contractor to provide security support services for the Office of Safety and Security , the Office of Science Consolidated Service Center, and the Oak Ridge Office of Environmental Management. The work location is in Oak Ridge, Tennessee. The mission of the support service contractor is to provide an array of site-wide security support functions that support Safeguards and Security responsibilities in a secure environment protecting critical national security assets. | - | Solicitation | 11/20/2026 |
Technology Summary: RELAP5-3D is a fully integrated system-level modeling code for simulating the behavior of nuclear power plants and other complex thermal-fluid systems. Originally developed for light water reactor safety analysis, RELAP5-3D supports detailed modeling of multiphase flow, heat transfer, reactor kinetics, and fluid-structure interactions. It is capable of performing both steady-state and transient analyses in one-, two-, or three-dimensional geometries, making it one of the most versatile nuclear systems analysis tools in use today. Problem Addressed: Designers, operators, and regulators of nuclear systems need validated tools to simulate a wide range of operating and accident scenarios, from routine transients to complex multi-physics events. Many commercial codes lack the physics detail or numerical flexibility needed to capture the behavior of advanced reactor designs, high-fidelity safety cases, or coupled systems involving multiple working fluids or complex geometries. Proposed Solution: RELAP5-3D enables high-fidelity simulations of nuclear thermal-hydraulics and safety behavior. Key capabilities include: Modeling of single- and two-phase flow using a two-fluid model Support for multiple fluids, flow regimes, and non-condensable gases Built-in reactor kinetics and neutron transport models (point kinetics or 3D neutron kinetics) Fully coupled heat structures and control system modeling Parallel processing and restart capabilities for large, complex runs Optional coupling with external tools for fuel performance, CFD, or systems-level co-simulation RELAP5-3D is actively maintained and enhanced to support modern reactor designs, including small modular reactors, high-temperature gas-cooled reactors, and liquid metal-cooled reactors. Key Advantages: Comprehensive Simulation Capabilities: Supports steady-state, transient, and accident analysis across multiple reactor types and configurations Multidimensional Modeling: Simulates flow and heat transfer in 1D, 2D, and 3D domains Built-In Neutronics: Includes tightly coupled neutron kinetics for integrated reactor core analysis High Fidelity and Flexibility: Validated models for a wide range of fluids, heat transfer modes, and operational conditions Interoperable Framework: Can be integrated with external modeling tools for coupled physics or system-level analysis Regulatory Acceptance: Used by U.S. national labs, industry, and regulators for licensing and safety evaluation Market Applications: •Advanced Reactor Design and Licensing: Used by developers of SMRs, microreactors, and Gen-IV systems Safety Analysis: Supports regulatory submittals and design basis accident analysis for existing and new reactors Plant Performance Evaluation: Useful for plant optimization, transient analysis, and control strategy development R&D and Academic Use: Widely used in national laboratories and universities for education and research Coupled System Modeling: Applicable in multi-domain simulations, including hybrid energy systems and integrated energy parks Licensing Opportunity: INL’s Technology Deployment department focuses solely on licensing intellectual property and collaborating with industry partners who can commercialize our innovations. We do not engage in purchasing, procurement, or hiring external services for technology development. Our objective is to connect with companies interested in licensing and bringing our technologies to market. | - | Special Notice | 11/01/2026 |
Opportunity: NETL is actively seeking collaboration to advance and commercialize an innovative adsorptive method for the highly efficient recovery of Heavy Rare Earth Elements (HREEs) and other Critical Minerals (CMs) from coal and its derivatives. This groundbreaking approach integrates physical enrichment for feedstock pre-concentration, significantly enhancing overall process efficacy. Background: Traditional HREE/CM extraction from coal derivatives is often costly, energy-intensive, and chemical-laden. Existing multi-step chemical extraction operations rely on vast amounts of expensive solvents and chemicals, resulting in low recovery and impure products due to inherently low REE concentrations. The heterogeneity of coal byproducts also demands complex pre-treatment, preventing a universal solution. Thus, there is an urgent need for cost-effective extraction technologies that significantly reduce chemical and energy consumption while offering feedstock flexibility. Description: NETL researchers have developed a process for the cost-effective recovery of concentrated HREEs and other critical minerals (CMs), including Gallium, Germanium, Vanadium, Cobalt, and Nickel. This method significantly reduces processing time to less than 5 minutes, demonstrates high selectivity for HREEs and CMs over fouling metals exceeding 1,000, and is proven effective with coal, coal refuse, and their derivatives. The core process involves an adsorptive technology to recover HREEs and CMs from coal and coal-derived solutions, followed by the release of high-purity HREEs and CMs through a pH-swing regeneration operation. Configured with multiple adsorption columns, the method can be continuously operated. It also incorporates a physical separation step, flotation or sonication enhanced flotation, for pre-concentrating REEs within the feedstock. This unique NETL method successfully recovers HREEs and CMs from feedstocks even at parts-per-million concentrations. By offering unparalleled low-maintenance requirements, affordability, and scalability compared to existing alternatives, it establishes a new standard for HREE/CM recovery technology. Advantages/Benefits: Improved cost efficiency. Minimal pressure drop. High capacity and selectivity for HREEs Short sorption contact times. Regenerable and robust performance tested in cyclability studies. Potential Applications: Coal refuse/waste streams Mine tailing/waste streams Acid mine drainage Industrial demineralization Development Status: Current stage of technology development: TRL ☐ 0-2 ☒ 3-5 ☐ 5-9 NETL has filed for patent protection on this invention. NETL is actively seeking industry partners with the capability and vision to bring this critical technology to market. By moving this innovation beyond the laboratory and into commercial application, our partners can gain a significant competitive advantage through licensing and/or cooperative research and development collaborations. Interested parties are invited to discuss this opportunity further under non-disclosure agreements to safeguard proprietary information. NOTE: THIS IS NOT A PROCUREMENT. Entities interested in developing technologies for HREE and CM recovery should provide an electronic or written statement of interest, which includes the following: 1. Company Name and Address 2. The name, address and telephone number of a point of contact 3. A description of the relevant expertise and/or facilities Please provide a complete statement to ensure consideration of your interest in this opportunity. The subject heading in an email response should include the Notice ID and the title of the opportunity and be directed to the Primary and Secondary points of contact listed below. | - | Special Notice | 11/10/2026 |
Mission Execution Support Services | - | Awarded | Open |
Additional Details
Solicitation Number
89243326NFE000255
Archive Date
Oct 2, 2026
Office Address
MORGANTOWN, WV, 26507