GovChime
Notice ID: da3d5c0b44d5464e8202ef95a301973dAward NoticeAwardedArchived

A--Development of electromagnetic transmitter and receiver technology.

Awarded on September 17, 2026. Full description on SAM.gov.

Awarded tounder 89243326PFE001009 (source: SAM.gov award notice)• $598.0K

Overview

Posted
September 17, 2026
Notice type
Award Notice
NAICS
541690: Other Scientific and Technical Consulting Services
Agency
Department of Energy

Notice details

Office
NATIONAL ENERGY TECHNOLOGY LABORATORY
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov
Award date
Sep 17, 2026
Award amount (SAM.gov award notice)
$598.0K

Identifiers

Solicitation number
89243326NFE000255
Notice ID
da3d5c0b44d5464e8202ef95a301973d
Award number (PIID)
89243326PFE001009

Description

Development of electromagnetic transmitter and receiver technology.

Full description on SAM.gov

Award Overview

Award Number

89243326PFE001009

Award Amount (SAM.gov award notice)

$598.0K

Award Date

Sep 17, 2026

Awardee

Awardee UEI

D4MBFWQ1NGW7

Awardee CAGE Code

42HX3

Awardee Address

1140 Applegate St Unit 1045, Philomath, OR 97370, UNITED STATES

Original Solicitation

Notice ID: da3d5c0b44d5464e8202ef95a301973d

Posted Date: Sep 17, 2026

Original Response Deadline: Not specified

Contacts

Contracting Officer

Primary Contact

Documents

No documents available.

Lifecycle

  1. 3
    Version 3Award NoticeArchivedCurrent

    A--Development of electromagnetic transmitter and receiver technology.

    Notice da3d5c0b44d5464e8202ef95a301973d on SAM.gov

Other notices for this solicitation

  1. Special NoticeRelated noticeAug 19, 2026

    A--Notice of Intent to Sole Source for an electromagnetic transmitter to IoMT LLC.

    Notice 39cf0e6a6bc04d68b32fe22b2c855d7f on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Louis A Johnson Medical Center seeks a contractor to provide industrial hygiene support, specifically quantitative respirator fit testing, for medical center employees. The contractor will supply all necessary fit testing equipment (such as TSI PortaCount machines), consumables, and Controlled Air Purifying Respirators (CAPRs) for personnel requiring alternatives to N95 respirators. Training for CAPRs and qualitative fit testing may also be required, depending on operational needs.
-Combined Synopsis11/05/2026
The Department of Energy Office of Science requires a single contractor to provide security support services for the Office of Safety and Security , the Office of Science Consolidated Service Center, and the Oak Ridge Office of Environmental Management. The work location is in Oak Ridge, Tennessee. The mission of the support service contractor is to provide an array of site-wide security support functions that support Safeguards and Security responsibilities in a secure environment protecting critical national security assets.
-Solicitation11/20/2026
Technology Summary: RELAP5-3D is a fully integrated system-level modeling code for simulating the behavior of nuclear power plants and other complex thermal-fluid systems. Originally developed for light water reactor safety analysis, RELAP5-3D supports detailed modeling of multiphase flow, heat transfer, reactor kinetics, and fluid-structure interactions. It is capable of performing both steady-state and transient analyses in one-, two-, or three-dimensional geometries, making it one of the most versatile nuclear systems analysis tools in use today. Problem Addressed: Designers, operators, and regulators of nuclear systems need validated tools to simulate a wide range of operating and accident scenarios, from routine transients to complex multi-physics events. Many commercial codes lack the physics detail or numerical flexibility needed to capture the behavior of advanced reactor designs, high-fidelity safety cases, or coupled systems involving multiple working fluids or complex geometries. Proposed Solution: RELAP5-3D enables high-fidelity simulations of nuclear thermal-hydraulics and safety behavior. Key capabilities include: Modeling of single- and two-phase flow using a two-fluid model Support for multiple fluids, flow regimes, and non-condensable gases Built-in reactor kinetics and neutron transport models (point kinetics or 3D neutron kinetics) Fully coupled heat structures and control system modeling Parallel processing and restart capabilities for large, complex runs Optional coupling with external tools for fuel performance, CFD, or systems-level co-simulation RELAP5-3D is actively maintained and enhanced to support modern reactor designs, including small modular reactors, high-temperature gas-cooled reactors, and liquid metal-cooled reactors. Key Advantages: Comprehensive Simulation Capabilities: Supports steady-state, transient, and accident analysis across multiple reactor types and configurations Multidimensional Modeling: Simulates flow and heat transfer in 1D, 2D, and 3D domains Built-In Neutronics: Includes tightly coupled neutron kinetics for integrated reactor core analysis High Fidelity and Flexibility: Validated models for a wide range of fluids, heat transfer modes, and operational conditions Interoperable Framework: Can be integrated with external modeling tools for coupled physics or system-level analysis Regulatory Acceptance: Used by U.S. national labs, industry, and regulators for licensing and safety evaluation Market Applications: •Advanced Reactor Design and Licensing: Used by developers of SMRs, microreactors, and Gen-IV systems Safety Analysis: Supports regulatory submittals and design basis accident analysis for existing and new reactors Plant Performance Evaluation: Useful for plant optimization, transient analysis, and control strategy development R&D and Academic Use: Widely used in national laboratories and universities for education and research Coupled System Modeling: Applicable in multi-domain simulations, including hybrid energy systems and integrated energy parks Licensing Opportunity: INL’s Technology Deployment department focuses solely on licensing intellectual property and collaborating with industry partners who can commercialize our innovations. We do not engage in purchasing, procurement, or hiring external services for technology development. Our objective is to connect with companies interested in licensing and bringing our technologies to market.
-Special Notice11/01/2026
Opportunity: NETL is actively seeking collaboration to advance and commercialize an innovative adsorptive method for the highly efficient recovery of Heavy Rare Earth Elements (HREEs) and other Critical Minerals (CMs) from coal and its derivatives. This groundbreaking approach integrates physical enrichment for feedstock pre-concentration, significantly enhancing overall process efficacy. Background: Traditional HREE/CM extraction from coal derivatives is often costly, energy-intensive, and chemical-laden. Existing multi-step chemical extraction operations rely on vast amounts of expensive solvents and chemicals, resulting in low recovery and impure products due to inherently low REE concentrations. The heterogeneity of coal byproducts also demands complex pre-treatment, preventing a universal solution. Thus, there is an urgent need for cost-effective extraction technologies that significantly reduce chemical and energy consumption while offering feedstock flexibility. Description: NETL researchers have developed a process for the cost-effective recovery of concentrated HREEs and other critical minerals (CMs), including Gallium, Germanium, Vanadium, Cobalt, and Nickel. This method significantly reduces processing time to less than 5 minutes, demonstrates high selectivity for HREEs and CMs over fouling metals exceeding 1,000, and is proven effective with coal, coal refuse, and their derivatives. The core process involves an adsorptive technology to recover HREEs and CMs from coal and coal-derived solutions, followed by the release of high-purity HREEs and CMs through a pH-swing regeneration operation. Configured with multiple adsorption columns, the method can be continuously operated. It also incorporates a physical separation step, flotation or sonication enhanced flotation, for pre-concentrating REEs within the feedstock. This unique NETL method successfully recovers HREEs and CMs from feedstocks even at parts-per-million concentrations. By offering unparalleled low-maintenance requirements, affordability, and scalability compared to existing alternatives, it establishes a new standard for HREE/CM recovery technology. Advantages/Benefits: Improved cost efficiency. Minimal pressure drop. High capacity and selectivity for HREEs Short sorption contact times. Regenerable and robust performance tested in cyclability studies. Potential Applications: Coal refuse/waste streams Mine tailing/waste streams Acid mine drainage Industrial demineralization Development Status: Current stage of technology development: TRL ☐ 0-2 ☒ 3-5 ☐ 5-9 NETL has filed for patent protection on this invention. NETL is actively seeking industry partners with the capability and vision to bring this critical technology to market. By moving this innovation beyond the laboratory and into commercial application, our partners can gain a significant competitive advantage through licensing and/or cooperative research and development collaborations. Interested parties are invited to discuss this opportunity further under non-disclosure agreements to safeguard proprietary information. NOTE: THIS IS NOT A PROCUREMENT. Entities interested in developing technologies for HREE and CM recovery should provide an electronic or written statement of interest, which includes the following: 1. Company Name and Address 2. The name, address and telephone number of a point of contact 3. A description of the relevant expertise and/or facilities Please provide a complete statement to ensure consideration of your interest in this opportunity. The subject heading in an email response should include the Notice ID and the title of the opportunity and be directed to the Primary and Secondary points of contact listed below.
-Special Notice11/10/2026
Mission Execution Support Services
-AwardedOpen

Additional Details

Solicitation Number

89243326NFE000255

Archive Date

Oct 2, 2026

Office Address

MORGANTOWN, WV, 26507