Y--Weld Substation Stage 05
Awarded on August 25, 2026. Full description on SAM.gov.
Overview
- Posted
- August 25, 2026
- Notice type
- Award Notice
- NAICS
- 237130: Power and Communication Line and Related Structures Construction
- Agency
- Department of Energy
Notice details
- Office
- WESTERN-ROCKY MOUNTAIN REGION
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
- Award date
- Aug 25, 2026
- Award amount (SAM.gov award notice)
- $2.3M
Identifiers
- Solicitation number
- 89503226BWA000074
- Notice ID
- b0275b30a0694865b9ea9e6f12ad7c3d
- Award number (PIID)
- 89503226CWA000128
Description
Award Overview
Award Number
89503226CWA000128
Award Amount (SAM.gov award notice)
$2.3M
Award Date
Aug 25, 2026
Awardee
Awardee UEI
D4N8K3L9E824
Awardee CAGE Code
48738
Awardee Address
1526 HORSE CREEK RD, Cheyenne, WY 82009, UNITED STATES
Original Solicitation
Notice ID: b0275b30a0694865b9ea9e6f12ad7c3d
Posted Date: Aug 25, 2026
Original Response Deadline: Not specified
Contract Details
Contract data not yet available
Contract details typically appear within 2-4 weeks after award; DoD awards are published about 90 days after signature.
Contacts
Contracting Officer
Primary Contact
Documents
Links (1)
- Click here to see more information about this opportunity on FedConnectwww.fedconnect.netPosted
Lifecycle
- 2Version 2SolicitationArchived
Y--Weld Substation Stage 05
- 5Version 5Award NoticeArchivedCurrent
Type changed from Solicitation to Award Notice
Y--Weld Substation Stage 05
Other notices for this solicitation
- Pre-SolicitationRelated noticeMay 20, 2026
Y--Weld Substation Stage 05
- SolicitationRelated noticeJun 5, 2026
Y--Weld Substation Stage 05
- SolicitationRelated noticeJun 5, 2026
Glendo-Lusk Rural Tap and Quinn Creek Substation
- SolicitationRelated noticeJun 8, 2026
Y--Weld Substation Stage 05
- SolicitationRelated noticeJul 2, 2026
Y--Weld Substation Stage 05
- SolicitationRelated noticeJul 2, 2026
Y--Weld Substation Stage 05
- SolicitationRelated noticeJul 7, 2026
Y--Weld Substation Stage 05
- SolicitationRelated noticeJul 16, 2026
Y--Weld Substation Stage 05
- SolicitationRelated noticeJul 22, 2026
Y--Weld Substation Stage 05
- SolicitationRelated noticeJul 24, 2026
Y--Weld Substation Stage 05
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Folsom Dam Electronic Access Control and Surveillance (EACSS) Fiber Backbone Upgrade | - | Pre-Solicitation | 11/16/2026 |
ACTION: Pre-Solicitation Notice PRE-SOLICITATION NUMBER: 140P2024R0130 CLASSIFICATION CODE: Y1NZ - Construction of other utilities. CONTRACTING OFFICER: Tim Burger CONTRACT SPECIALIST: Brian Baugh DSC-CS Contracting Services Division National Park Service P.O. Box 25287 Denver, CO 80225 POINT OF CONTACT: CONTRACTING OFFICER: tim_burger@nps.gov CONTRACT SPECIALIST: brian_baugh@contractor.nps.gov PLACE OF PERFORMANCE: Voyageurs National Park, Minnesota. PLACE OF PERFORMANCE COUNTRY: USA Title of Project: Replace Power Distribution line. GENERAL: The National Park Service (NPS), Department of Interior (DOI), Denver Service Center (DSC), is soliciting proposals on a full and open basis from all interested businesses having the capability to perform the work described below. The solicitation will be issued electronically on the Federal Business Opportunities website at www.fedbizopps.gov . Proposal documents will be available for download in Microsoft Word, HTML, Microsoft Excel, and Adobe PDF; Specifications will be available in Adobe PDF format; and drawings will be available in PDF format. Please Note: Paper copies of the solicitation will not be made available. Vendors can search for opportunities and award history on www.fbo.gov without registering. The Federal Business Opportunities (www.fbo.gov) website has an Interested Vendors List and a Watchlist where you can add your company¿s interest. Registering provides the opportunity to receive notifications; this is a tool of convenience only and does not serve as a guarantee of notification. Interested vendors and plan holders are required to visit the website periodically to check for amendments and other changes to the synopsis or solicitation documents. Prospective offerors desiring to conduct business with the DOI are required to have an active registration in the Systems for Awards Management (SAM) at www.sam.gov. You are also required to have a DUNS number in order to conduct business with the Federal Government. This pre-solicitation announcement is not a solicitation document, but pre-notice of an upcoming solicitation. Specific instructions on submitting your proposal will be contained in the solicitation documents to be issued on or after the date listed below. Proposed Solicitation Issue Date: Estimated on/about September 3, 2024 This is currently an unfunded requirement with a high expectation that funds will be available. When and if funds become available a contract will be awarded at that time. The NAICS Code for this requirement is 237130 with a size standard of $45 million. Description: This project will replace the main underwater high voltage cable and multiple transformer boxes that run from the mainland to the Kettle Falls district. Pad-mounted switchgear, sectionalizing enclosures, elbow terminations, as well as individual and other associated components will be replaced as needed. An improved level of emergency backup generation for critical loads at Kettle Falls Area will be installed. Due to the compromised neutral wire, this poses a serious safety risk to visitors as well as employees. The neutral serves as a ground for the cable, and as more lightning strikes occur the chances of someone being struck increase. Secondly when power goes out facilities are forced to be closed such as restrooms, showers, and the restaurant. There is also a food safety factor at the restaurant due to the freezers and coolers loss of power. This has potential for food to develop bacteria that could lead to sickness of visitors. The Fire suppression system pumps are run by electricity; therefore, if there is no power then there is no fire protection for the Historic hotel. This jeopardizes the visitor's safety as well as the historic building. The new backup generator would allow the concession to continue to stay operational in the event of a power outage. Estimated Price Range: Over $10,000,000 Estimated Period of Performance: 730 calendar days Proposal receipt date is not known at this time. The actual date will be established in the solicitation documents A pre-proposal meeting may be posted and date/location will be noted in the solicitation or a forthcoming amendment. This procurement will be competed via full and open. All responsible sources may submit an offer which, if submitted in a timely manner, will be considered. It is the policy of the government to provide maximum practicable opportunities in its acquisitions to small business, veteran-owned small business, small disadvantaged business, and women-owned small business concerns. Such concerns must also have the maximum practicable opportunity to participate as subcontractors in the contracts awarded by any executive agency, consistent with efficient contract performance. All offerors are strongly encouraged to contact their local Small Business Administration Office, to post their need for qualified subcontractors at http://www.sba.gov . | - | Pre-Solicitation | 10/03/2024 |
This announcement is to all Small Business, 8(a) Small Business, HUBZone Small Business, Indian Small Business Economic Enterprises, Service-Disabled Veteran-Owned Small Business and Women-Owned Small Business concerns that may be interested in performing a contract for the California Great Basin Region of the Bureau of Reclamation. The work to be performed is described below. Based upon response to this announcement, the Government may determine to set this acquisition aside or proceed with an unrestricted solicitation. The applicable North American Industry Classification System (NAICS) Code is 237110 and the related small business size standard is $45M. This notice is not a request for proposal and the information presented in this announcement will not obligate the Bureau of Reclamation in any manner. The estimated cost of this project is $500,000.00-$1,000,000.00. This procurement will require 100% performance and payment bonds. This sources sought notice is for market research and acquisition planning purposes only. No formal solicitation for this work exists at this time. The work is located at the Oak Shores and Smittle Recreation Areas located in Napa County, California. Interested parties should include the following information in their response: (a) Business name, address, cage code, size classification based on NAICS size standard, socioeconomic classification (i.e. HUBZone; 8(a), etc.), and a point of contact; (b) A positive statement of your intention to submit an offer for this solicitation as a prime contractor; (c) Evidence of your experience performing work similar in type and scope to the work in this announcement within the last five years. The evidence should include: contract numbers, project titles, dollar amounts and points of contacts with telephone numbers. Please do not include more than three past projects; and (d) Include attachments cataloging the company's equipment assets, personnel resources and financial resources that demonstrate company responsibility and capability to perform required work. (e) If bonding is required, also provide evidence of your bonding capacity; All interested parties are encouraged to respond to this notice, by e-mail to Marianna_mezentseva@ios.doi.gov not later than 5PM PDT on November 11, 2026. The information provided in this announcement is all information the Government has available at this time. There are no specifications, drawings, bid packages, or source lists available. System for Award Management (SAM) applies to this procurement. Prospective contractors must be registered in the System for Award Management (SAM) prior to award. Lack of registration in the SAM database will make an offeror ineligible for award. Information on SAM registration can be obtained via the Internet at http://www.sam.gov PRINCIPAL COMPONENTS OF WORK: ¿ Replace 2¿ gate lateral valve at Main rated for 200 psi. ¿ Install N30 utility valve box w/water on lid, and appropriate quantity of risers to surface grade at Main lateral shut off 2¿ valve ¿ Reduce to 1¿ for lateral pipe to C.S. Install 1¿ lateral water line from main line 2¿ valve to PRV and 1¿ gate valve at rear of C.S. at Chase room ¿ Install 1¿ pressure reducing valve and 1¿ gate valve at rear of C.S. at Chase room Exterior in the proximity ¿ Install 1¿ pressure reducing valve and 1¿ gate valve rated for 200 psi. ¿ Install N30 utility valve box w/water on lid, and appropriate quantity of risers to surface grade over 1¿ PRV and gate valve ¿ Drill holes in brick on each side of C.S. Chase room access door approx. 1 ft above exterior floor ¿ Install 1¿ galvanized pipe from exterior PRV/gate valve, split into 2 lines, and run pipe in each hole to near interior copper line connection point. Fill wall holes with concrete. ¿ Install interior PRV and 1¿ gate valve, and tee with pressure gauge (1¿ face 0 to 60 psi) after PRV between 1¿ galvanized pipe and copper pipe, connect to copper pipe on each side of Chase room ¿ Flush and pressure test all connections prior to backfill of excavation from main lie to copper line connections interior of Chase room | - | Market Research | 11/11/2026 |
November 5, 2026- Amendment 1 issued to clarify timne and location of the Pre-Proposal Meeting. This scope of work is to rebuild and renovate the Kautz Road Substation (KRS), which is UIP subproject SP-2. The KRS supplies electricity to various lab buildings and systems. These systems serve both conventional facility needs, as well as process utility requirements. It is vital to Fermilab’s mission that KRS be revitalized and expanded, ensuring the ability to serve existing and future loads. The General contractor shall furnish all required supervision, labor, materials, tools, plant and appurtenances necessary to perform diligently and fully all work as described in the drawings and technical specifications. All work includes transportation, overhead, bonding costs, safety oversight, quality control oversight, and supervision as required to construct the project described in the drawings, technical specification and the detailed description contained herein. The critical schedule constraint for construction of this project is Fermilab’s accelerator shutdown, with an anticipated scheduled start on January 1, 2028, and anticipated end date of January 1, 2030- these dates may change depending on the needs of the Lab. The General Contractor must start their on-site efforts, and complete the construction scope under this contract, within the shutdown window. This project includes the following milestones: Milestone 1 – 60 Calendar Days after issuance of Notice to Proceed (NTP). This milestone is intended for completion of necessary submittals and RFIs, approval of shop drawings for fabrication and procurement. Milestone 2 – 4th January 2028; This milestone marks the point where access is permitted inside Kautz Road Substation yard and construction work may begin. Milestone 3 – 31st of March 2028; This milestone marks the completion of building foundation and ready for placement of the new prefabricated control house building (provided by FermiForward). Milestone 4 – 2nd July 2029; This milestone marks the formal issuance of an Authorization for Use and Possession (AUP) of the KRS Substation facility, including all remedial work following removal of site trailers, but not including seasonal work and all final punch list items addressed.. Milestone 5 – 30th September 2029; This milestone marks the completion of the project. | - | Solicitation | 12/18/2026 |
Amendment 7- Extend proposal due date to 11/13/2026- California Oregon Transmission Project (COTP) Two-Phase Design-Build 525kV Series Capacitor Bank Replacement Project | - | Solicitation | 11/13/2026 |
Additional Details
Solicitation Number
89503226BWA000074
Archive Date
Sep 9, 2026
Office Address
LOVELAND, CO, 80538