Y--Shiprock-Vernal-Hayden Substation HVAC

Awarded on August 6, 2026. Full description on SAM.gov.

Awarded tounder 89503226CWA000127 (source: SAM.gov award notice)• $61.8K

Overview

Posted
August 6, 2026
Notice type
Award Notice

Notice details

Office
WESTERN-ROCKY MOUNTAIN REGION
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov
Award date
Aug 6, 2026
Award amount (SAM.gov award notice)
$61.8K

Identifiers

Solicitation number
89503226RWA000025
Notice ID
b3a19c10d86f4bc1a3b45eee578d54c7
Award number (PIID)
89503226CWA000127

Description

Shiprock-Vernal-Hayden Substation HVAC - replace the heating, ventilation, and air conditioning (HVAC) systems in the garage and service buildings at Hayden Substation in Routt County, Colorado; in the microwave building within the confines of Shiprock Substation in San Juan County, New Mexico; and in the service building within the confines of Vernal Substation in Uintah County, Utah. Equipment used for the proposed action includes hand tools as well as any tools required for the refrigerant removal and addition. Work will be completed within the confines of WAPA’s Hayden and Vernal Substations on WAPA lands, and within the confines of WAPA’s Shiprock Substation on Bureau of Land Management-Farmington Field Office lands. The substations will be accessed by existing access routes; no access road maintenance or new road construction is authorized. Work may occur at any time prior to the expiration date.

Full description on SAM.gov

Award Overview

Award Number

89503226CWA000127

Award Amount (SAM.gov award notice)

$61.8K

Award Date

Aug 6, 2026

Awardee

Awardee UEI

QQKUBHK3TKQ3

Awardee CAGE Code

7MRG6

Awardee Address

830 VIVIAN ST, Lakewood, CO 80401, UNITED STATES

Original Solicitation

Notice ID: b3a19c10d86f4bc1a3b45eee578d54c7

Posted Date: Aug 6, 2026

Original Response Deadline: Not specified

Contract Details

Contract data not yet available

Contract details typically appear within 2-4 weeks after award; DoD awards are published about 90 days after signature.

Contacts

Contracting Officer

Primary Contact

Documents

Lifecycle

  1. 4
    Version 4SolicitationArchived

    Shiprock-Vernal-Hayden Substation HVAC

    Notice fd7fbb64785f43ceb09cce5ade6a382b on SAM.gov

  2. 6
    Version 6Award NoticeArchivedCurrent

    Type changed from Solicitation to Award Notice

    Y--Shiprock-Vernal-Hayden Substation HVAC

    Notice b3a19c10d86f4bc1a3b45eee578d54c7 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Folsom Dam Electronic Access Control and Surveillance (EACSS) Fiber Backbone Upgrade
62%
Pre-Solicitation11/16/2026
SOURCES SOUGHT NOTICE Electrical Upgrades to Support Future Three-Phase Power Supply Service - Lac qui Parle Dam near Watson, MN Notice ID: W912ES27SS0001 Issuing Office: U.S. Army Corps of Engineers (USACE) - St. Paul District Response Due Date and Time: 19 Nov 2026, 5:00pm (central time) 1.0 General Information Primary Point of Contact: Name: Justin Rose Title: Contract Specialist Email: justin.h.rose@usace.army.mil Secondary Point of Contact: Name: Sharon Frank-Scheierl Title: Contracting Officer Email: sharon.m.frank-scheierl@usace.army.mil NAICS Code: 237130, Power and Communication Line and Related Structures Construction Small Business Size Standard: $45 million Place of Performance: Lac qui Parle Dam, Watson, MN 56295. 2.0 Disclaimer This Sources Sought notice is issued in accordance with Revolutionary FAR Overhaul (RFO) Federal Acquisition Regulation (FAR) 15.201 for market research and planning purposes only and does not constitute a solicitation or a promise to issue a solicitation in the future. This notice does not commit the U.S. Government to contract for any supply or service whatsoever. The Government will not award a contract based on responses to this notice. The Government is not responsible for any costs incurred by respondents in the preparation of information for submission in response to this notice. All information received in response to this notice that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. All responsible sources may submit a capability statement, which shall be considered by the agency. 3.0 Project Description & Background The USACE - St. Paul District is conducting market research to identify qualified sources capable of performing electric upgrades at Lac qui Parle Dam near Watson, MN. Anticipated Scope of Work: The anticipated work is intended to prepare the dam for future three-phase gate-actuator upgrades while maintaining operation of existing 120/240-volt, single-phase actuators. The construction contractor’s anticipated work includes furnishing all labor, tools, equipment, supervision, testing, and incidental work necessary to: Maintain/refeed the single phase 120/240-volt transformer located on the southeast side of the dam for lighting, gage house, and toilet area; Supply and install multiple utility poles (likely from the south heading north); Supply and install three (3) 480-volt transformers and metering equipment on final utility pole near dam; Connection from an existing 480-volt, three-phase source to a new service/distribution panel; Existing conduit and conductors will be demolished and cut (removal of demolished conduit will be completed by USACE); Existing single-phase feed to the dam will be disconnected by the contractor, the contractor may salvage the wire; Coordinate easements with the U.S. Army Corps of Engineers (and Lac qui Parle County for any work is off USACE property); Coordinate metering, transformers, power access, and other needs with USACE and MN Valley Light and Power (local utility service); Testing, grounding, submittals, and applicable state inspection; Potential for tree and brush removal. Objective: USACE is seeking market feedback on: The availability of qualified small businesses; Appropriate NAICS and size standard; Feasibility of a small-business set-aside; Likely construction duration, lead times, and site/utility coordination constraints. Schedule Flexibility: The Government anticipates coordinating the work with the serving utility. Any resulting solicitation will identify the anticipated period of performance, access procedures, outage coordination requirements, and site-visit information. Estimated Magnitude for Construction: The estimated magnitude of this project is between $30,000.00 and $70,000.00. The Government is seeking information to assess market capability, small-business interest, appropriate acquisition strategy, and potential schedule or utility-coordination concerns. 4.0 Information Requested from Interested Parties Interested firms are invited to submit a capability statement of no more than two (2) pages, not including attachments like letters of commitment. The Government is requesting only the minimum information necessary to determine capability, in accordance with RFO FAR 10.001. Your response must include the following information: Firm name, address, primary point of contact (name, title, phone, email); SAM UEI/CAGE and business-size/socioeconomic status under the selected NAICS; Please certify your firm's status for NAICS 237130: Small Business (SB), 8(a) Business Development, HUBZone, Service-Disabled Veteran-Owned Small Business (SDVOSB), Woman-Owned Small Business (WOSB), or Other than Small Business Confirmation of capacity to perform licensed electrical construction work in Minnesota; At least two (2) relevant projects, with a brief description and approximate value; Whether the firm can self-perform the principal electrical work; Interest in a site visit, if one is contemplated; Any material concerns with the anticipated scope, schedule, utility coordination, outage requirements, or permitting/inspection. Capability and Experience Capability Narrative: A brief narrative describing your firm's capabilities, special qualifications, certifications, and equipment relevant to performing the work described in Section 3.0 above. Relevant Project Experience: Provide at least two (2) examples of projects completed within the last five (5) years that are similar in size, scope, and complexity to this requirement. For each project, provide: * Project Title and Location * Contract Number and Type * Initial and Final Contract Value and Completion Dates Period of Performance * Role (Prime Contractor or Subcontractor) and percentage of work self-performed. * A brief narrative describing the project and how it relates to the scope of this notice. * A customer point of contact (Name, Title, Phone, Email). 5.0 Submission Instructions Responses are due no later than the date and time specified in this notice. Submit responses electronically to the Primary and Secondary Points of Contact. The email subject line shall read: "Sources Sought Response: Notice ID W912ES27SS0001 - [Your Company Name]" or similar. Marketing materials are not requested and will not be reviewed. Do not submit a proposal.
59%
Market Research11/19/2026
Amendment 8- Extend proposal due date to 03/05/2027- California Oregon Transmission Project (COTP) Two-Phase Design-Build 525kV Series Capacitor Bank Replacement Project
54%
Solicitation03/05/2027
November 5, 2026- Amendment 1 issued to clarify timne and location of the Pre-Proposal Meeting. This scope of work is to rebuild and renovate the Kautz Road Substation (KRS), which is UIP subproject SP-2. The KRS supplies electricity to various lab buildings and systems. These systems serve both conventional facility needs, as well as process utility requirements. It is vital to Fermilab’s mission that KRS be revitalized and expanded, ensuring the ability to serve existing and future loads. The General contractor shall furnish all required supervision, labor, materials, tools, plant and appurtenances necessary to perform diligently and fully all work as described in the drawings and technical specifications. All work includes transportation, overhead, bonding costs, safety oversight, quality control oversight, and supervision as required to construct the project described in the drawings, technical specification and the detailed description contained herein. The critical schedule constraint for construction of this project is Fermilab’s accelerator shutdown, with an anticipated scheduled start on January 1, 2028, and anticipated end date of January 1, 2030- these dates may change depending on the needs of the Lab. The General Contractor must start their on-site efforts, and complete the construction scope under this contract, within the shutdown window. This project includes the following milestones: Milestone 1 – 60 Calendar Days after issuance of Notice to Proceed (NTP). This milestone is intended for completion of necessary submittals and RFIs, approval of shop drawings for fabrication and procurement. Milestone 2 – 4th January 2028; This milestone marks the point where access is permitted inside Kautz Road Substation yard and construction work may begin. Milestone 3 – 31st of March 2028; This milestone marks the completion of building foundation and ready for placement of the new prefabricated control house building (provided by FermiForward). Milestone 4 – 2nd July 2029; This milestone marks the formal issuance of an Authorization for Use and Possession (AUP) of the KRS Substation facility, including all remedial work following removal of site trailers, but not including seasonal work and all final punch list items addressed.. Milestone 5 – 30th September 2029; This milestone marks the completion of the project.
49%
Solicitation12/18/2026
This announcement is to all Small Business, 8(a) Small Business, HUBZone Small Business, Indian Small Business Economic Enterprises, Service-Disabled Veteran-Owned Small Business and Women-Owned Small Business concerns that may be interested in performing a contract for the California Great Basin Region of the Bureau of Reclamation. The work to be performed is described below. Based upon response to this announcement, the Government may determine to set this acquisition aside or proceed with an unrestricted solicitation. The applicable North American Industry Classification System (NAICS) Code is 237110 and the related small business size standard is $45M. This notice is not a request for proposal and the information presented in this announcement will not obligate the Bureau of Reclamation in any manner. The estimated cost of this project is $500,000.00-$1,000,000.00. This procurement will require 100% performance and payment bonds. This sources sought notice is for market research and acquisition planning purposes only. No formal solicitation for this work exists at this time. The work is located at the Oak Shores and Smittle Recreation Areas located in Napa County, California. Interested parties should include the following information in their response: (a) Business name, address, cage code, size classification based on NAICS size standard, socioeconomic classification (i.e. HUBZone; 8(a), etc.), and a point of contact; (b) A positive statement of your intention to submit an offer for this solicitation as a prime contractor; (c) Evidence of your experience performing work similar in type and scope to the work in this announcement within the last five years. The evidence should include: contract numbers, project titles, dollar amounts and points of contacts with telephone numbers. Please do not include more than three past projects; and (d) Include attachments cataloging the company's equipment assets, personnel resources and financial resources that demonstrate company responsibility and capability to perform required work. (e) If bonding is required, also provide evidence of your bonding capacity; All interested parties are encouraged to respond to this notice, by e-mail to Marianna_mezentseva@ios.doi.gov not later than 5PM PDT on November 11, 2026. The information provided in this announcement is all information the Government has available at this time. There are no specifications, drawings, bid packages, or source lists available. System for Award Management (SAM) applies to this procurement. Prospective contractors must be registered in the System for Award Management (SAM) prior to award. Lack of registration in the SAM database will make an offeror ineligible for award. Information on SAM registration can be obtained via the Internet at http://www.sam.gov PRINCIPAL COMPONENTS OF WORK: ¿ Replace 2¿ gate lateral valve at Main rated for 200 psi. ¿ Install N30 utility valve box w/water on lid, and appropriate quantity of risers to surface grade at Main lateral shut off 2¿ valve ¿ Reduce to 1¿ for lateral pipe to C.S. Install 1¿ lateral water line from main line 2¿ valve to PRV and 1¿ gate valve at rear of C.S. at Chase room ¿ Install 1¿ pressure reducing valve and 1¿ gate valve at rear of C.S. at Chase room Exterior in the proximity ¿ Install 1¿ pressure reducing valve and 1¿ gate valve rated for 200 psi. ¿ Install N30 utility valve box w/water on lid, and appropriate quantity of risers to surface grade over 1¿ PRV and gate valve ¿ Drill holes in brick on each side of C.S. Chase room access door approx. 1 ft above exterior floor ¿ Install 1¿ galvanized pipe from exterior PRV/gate valve, split into 2 lines, and run pipe in each hole to near interior copper line connection point. Fill wall holes with concrete. ¿ Install interior PRV and 1¿ gate valve, and tee with pressure gauge (1¿ face 0 to 60 psi) after PRV between 1¿ galvanized pipe and copper pipe, connect to copper pipe on each side of Chase room ¿ Flush and pressure test all connections prior to backfill of excavation from main lie to copper line connections interior of Chase room
49%
Market Research11/11/2026

Additional Details

Solicitation Number

89503226RWA000025

Archive Date

Aug 21, 2026

Office Address

LOVELAND, CO, 80538