Notice ID: a03549d6220c2e8b8d274cc4805009ddAward NoticeAwarded
UV Lamps
Awarded on September 25, 2019. Full description on SAM.gov.
Awarded tounder 191BWC19P0132 (source: SAM.gov award notice)• $130.2K
Overview
- Posted
- September 25, 2019
- Notice type
- Award Notice
- NAICS
- 335110: Classification Not Available
Notice details
- Place of performance
- Nogales Wastewater Treatment Plant 865 Rio Rico Industrial Park, Nogales, AZ, 85648
- PSC
- 46: WATER PURIFICATION/SEWAGE TREATMENT
- Last updated
- Dec 6, 2025
- Award date
- Sep 25, 2019
- Award amount (SAM.gov award notice)
- $130.2K
Identifiers
- Solicitation number
- 93093282127
- Notice ID
- a03549d6220c2e8b8d274cc4805009dd
- Award number (PIID)
- 191BWC19P0132
Description
The purpose of this amendment is to provide the question and answer received against this RFQ: Q1. Can you provide me with a part number for the UV Blubs, and the Quartz sleeves. There are several bulbs and sleeves for that model of Trojan UV unit. A1. The Trojan part numbers are: • Lamp: 794447-ORD • Quartz sleeve: 316136
Award Overview
Award Number
191BWC19P0132
Award Amount (SAM.gov award notice)
$130.2K
Award Date
Sep 25, 2019
Awardee
Awardee UEI
KNH5WMWSKMX9
Original Solicitation
Notice ID: a03549d6220c2e8b8d274cc4805009dd
Posted Date: Sep 25, 2019
Original Response Deadline: Not specified
Contract Details
No FPDS record matches this award number at the same department yet
Contract details typically appear within 2-4 weeks after award; DoD awards are published about 90 days after signature.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
93093282127- Combined Synopsis
- Awarded
This opportunity has been awarded.
- 2×
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
DMC Power Connectors for Warehouse Stock, Western Area Power Administration, Desert Southwest Region, Phoenix | - | Combined Synopsis | 11/19/2026 |
FINAL EXTENSION: Proposals are due no later than 30 November at 1300. NO ADDITIONAL EXTENSIONS WILL BE PROVIDED. Responses to Site Visit Q&A will be posted by 13 November 2026 at 1300 Arizona Time. The Government intends to hold a site visit for subject requirement on 4 November 2026 at 0900 AM. Below you will find the instructions and required documents to attend. Only SBA Certified Women Owned Small-Businesses are eligible for this requirement. **THIS IS THE ONLY DATE AND TIME FOR THE SITE VISIT, REQUESTS TO MAKE ANY CHANGES WILL BE DENIED** Attendance will be limited to 2 representatives for each contractor. To attend please provide the attached template (Site Visit Base Access_Template) completed with the below information, to rachel.tilley.1@us.af.mil, no later than 26 October 2026 at 1500 Arizona Time. Required Info: Last Name, First Name, DOB, US Citizen, License or ID#, State of Issue, Last 4 SSN To access the installation, the attendee will be required to have a REAL ID or Government Issued Passport. When submitting the above information, please include a copy of the form of ID to allow for Security Forces to verify if it meets the requirements. **QUESTIONS ARE DUE NO LATER THAN COB 22 OCTOBER 2026 at 1500 AZ time** ***FINALIZED Q&A Document will be posted with answers no later than 26 October 2026*** This SOW defines the requirement for the Contractor to Engineer, Furnish, Install and Test (EFI&T) new 12-Strand (St), Single Mode (SM) Fiber Optic Cable (FOC) from Radar Approach Control (RAPCON, B979) to Air Traffic Control Tower (ATCT, B998), Base Operation (Ops)B453), Command Post (CP, B11), Localizer (B1375), Glide Slope (GS, B1056), Tactical Air Navigation (TACAN, B1049), Ground Antenna Transmit and Receive (GATR, B1040), Glide Slope (B1081 and Localizer (B1059). Also, 12-St SM FOC from Base Ops (B453) to Primary and Secondary Automatic Meteorological Station (FMQ-19s). The work will be performed at Luke AFB AZ by using new and existing Manhole/Handhole Duct System. Some portion of the cable route/path will be Direct Buried. The Contractor shall provide all equipment, tools, materials, supplies, transportation, labor, supervision, management, and other incidentals necessary to meet the requirements as stated in this SOW. All equipment, supplies, or materials provided shall be new and not refurbished. No equipment, supplies, or material will be provided by the government. All materials used in this SOW must be rust-proof and corrosion-resistant, due to the nature of the environment. See attached Solicitation and supporting documents for additional information. | - | Combined Synopsis | 11/30/2026 |
This Source Sought notice is issued for market information and planning for future acquisition in accordance with (IAW) Federal Acquisition Regulation (FAR) 15.201(e). Responses to sources sought notice 36C26227Q0101 will improve the understanding of the Government s requirement and industry capabilities. It will enhance the Government s ability to obtain quality supplies and allow for potential offerors to judge whether or how they can satisfy the Government s requirement. This is not a solicitation announcement. Responses to this notice cannot be accepted by the Government to form a binding contract. Information received shall be safeguarded adequately from unauthorized disclosure. The Department of Veterans Affairs (VA), Network Contracting Office 22 (NCO 22) is seeking sources that can provide RECHAGEABLE LI-ION BATTERIES for VA Loma Linda in accordance with Sources Sought Notice (SSN) 36C26227Q0101, and Salient Characteristics. Reference attached SSN 36C26227Q0101, and Salient Characteristics for more details. Inquiries shall be submitted via email to Anthony.delacruz@va.gov. Please Reference SSN 36C26227Q0101 in subject email. Thank you! | - | Market Research | 11/16/2026 |
1. This is a combined synopsis/solicitation for commercial services/items prepared in accordance with the format in FAR Subpart 12.6 in conjunction with FAR Part 13, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a separate written solicitation will not be issued. 1.A. Project Title: UPS Battery Replacement 1.B. Project Location: San Diego VA Medical Center, 3350 La Jolla Village Drive, San Diego CA, 92161 1.C. Solicitation Type - Number: Request for Quotes (RFQ) - 36C26227Q0064. 1.D. Set Aside: This solicitation is SB total set-aside 1.E. Applicable NAICS code: 335910 Battery Manufacturing 1.F. Small Business Size Standard: 1250 Employees 1.G. Type of Contract: Firm Fixed Price 1.H. Period of Performance: 365 days from award of date 2. Key solicitation milestones are: 2.A. Submit any questions regarding this procurement via email to victor.oliveros@va.gov no later than 12:00 Pacific Local Time, November 4, 2026. No questions will be answered after this date/time unless determined to be in the best interest of the Government as determined by the Contracting Officer. Telephonic questions will not be accepted or returned. RFI responses will be responded to as necessary in amendment format which will be posted to contract opportunities at http://SAM.gov. 2.B. Submit written offers in accordance with the following instructions, as well as Addendum to FAR 52.212-1, Instruction to Offerors. Oral offers will not be accepted. Complete and submit the enclosed SF 1449 via email no later than 15:00 Pacific Local Time, November 10, 2026, to victor.oliveros@va.gov . Ensure the following are completed and/or included in the offer packet: 2.B.1. SF 1449 page 1, 2.B.1.a. Section B.1 - Vendor Information with SAM UEI Number 2.B.1.b. Section B.1 - Acknowledgement of amendments 2.B.1.c. Section B.3 - Schedule of Supplies identifying specific manufacturer and model number being offered 2.B.1.d. Section B.4 - Delivery Schedule 2.B.1.e. Section C.4 - VAAR 852.219-78 VA Notice of Limitations on Subcontracting- Certificate of Compliance of Supplies and Products 2.B.1.f. Section E.5 - FAR 52.212-3 Offeror Representations and Certifications Commercial Items | - | Combined Synopsis | 11/13/2026 |
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 33 (size standard of 1250 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. VA San Diego Healthcare System needs a contract for one time service to provide replacement of batteries for the Main Server UPS (Uninterrupted Power Supply) in Bldg. 1 Room BB100-1 at VA San Diego Medical Center. The UPS are powered by 2 battery cabinets (30 per cabinet), which provide backup power during outages of normal and emergency power. This will prevent data loss, equipment damage, and ensure the continuous operation of the facility's information technology main servers. However, those batteries average lifespan is past the manufacturer's recommendation of 5 years. The battery lifespan and peak condition is essential to keeping vital equipment powered on during power surges and unexpected power shutdown. The contractor will: (1) Verify UPS is operational prior to replacing batteries. (2) Place UPS from Inverter to Maintenance Bypass. (3) Lock out/Tag out (LOTO) primary feed (Panel EDM). Verify no power at the UPS. (4) Remove and replace 60 UPS batteries with battery type UPS12-545PLP. (5) Battery terminals will be connected and tightened down in accordance with the manufacturer s recommended torque value and documented. (6) Clear all Lock out/Tag out (LOTO) and place UPS from Maintenance Bypass to Inverter mode. (7) Verify UPS is operational. Submit 1 hard copy and 1 electronic copy of Service Report. (8) Dispose of all old batteries at approved hazardous waste collection facility. Salient Characteristics for Sixty (60), UPS12-545PLP to include the following: a. Battery Manufacture: C&D Technologies b. String Voltage: 360 c. Float Voltage: 410 d. Battery Part Number: UPS12-540MR e. Batteries in a String: 30 for each cabinet f. Number of Cells: 180 g. Rated AMP Hour: 123 h. Watts Per Cell: 506 i. 100% Baseline Milliohm Value: 2.5 j. Parent Equipment Manufacture: Mitsubishi k. Warring Milliohm Value: 3.1 l. Parent Equipment Model #: UP9833A-A154SU-4 m. Replacement Milliohm Value: 3.2 n. Parent Equipment Serial #: 02-GGF3Q1-02 o. Annual Torque Specification: 60 In - Lbs. Place of Performance: VA San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, CA 92161-0002 The list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SALIENT CHARACTERISTICS requirements. For instances where your company cannot meet the SALIENT CHARACTERISTICS requirement(s), please explain. For instances where your company can meet the SALIENT CHARACTERISTICS requirement(s), please show how your company meets/exceeds each requirement. (2) Please review the list of SALIENT CHARACTERISTICS requirements and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (4) Is your company considered small under the NAICS code identified in this RFI? (5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list SALIENT CHARACTERISTICS? (6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified. (8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6? (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (11) Please indicate whether your product conforms to the requirements of the Buy American Act? (12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate. (13) What is estimated life span of your solution? What support/services does that entail? (14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained. (15) Does your organization offer a leasing solution? Please elaborate. (16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (19) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to victor.oliveros@va.gov . Telephone responses will not be accepted. Responses must be received no later than, October 21, 2026, by 15:00 Pacific Local Time. All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement. | - | Market Research | 10/21/2026 |
Additional Details
Solicitation Number
93093282127
Archive Date