GovChime
Notice ID: 9c267915e382491ca7e822ab9b0065d4Sources SoughtArchived

RFI - 37250PR260000091 - USCG Sector San Diego - FAA Regulated Hangar Fire System Testing, Certification, and Maintenance + Standard Fire Equipment and Systems Testing and Certification

Archived on September 5, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
11:59 PM EDT
Posted
August 14, 2026
Notice type
Sources Sought
Set-aside
No Set aside used
NAICS
561621: Security Systems Services (except Locksmiths)
Agency
Department of Homeland SecurityUS COAST GUARD

Notice details

Office
BASE LOS ANGELES/LONG BEACH(00037)
Place of performance
San Diego, California, 92101
PSC
J012: MAINT/REPAIR/REBUILD OF EQUIPMENT- FIRE CONTROL EQUIPMENT
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
37250PR260000091
Notice ID
9c267915e382491ca7e822ab9b0065d4

Description

REQUEST FOR INFORMATION (RFI)

Inspection, Monthly Maintenance, and Repair of Fire Protection, Alarm Systems, and Equipment (Extinguishers, etc.)

In accordance with Federal Acquisition Regulation (FAR) Part 15 and the FAR Overhaul Guidelines (Executive Order 14275, "Restoring Common Sense to Federal Procurement"), this Request for Information (RFI) is issued solely for market research and planning purposes. It does not constitute a Request for Proposal (RFP) or a commitment to issue a solicitation in the future.

The U.S. Coast Guard (USCG) is seeking feedback from qualified, certified, and interested businesses to identify potential sources capable of performing comprehensive inspection, maintenance, testing, and repair services for various fire protection and alarm systems across multiple buildings at Sector San Diego and Helicopter Hangars.

This RFI is streamlined to promote early, open, and efficient exchanges with industry before any formal solicitation is released.

SCOPE

The following is a summary of the scope of work. The full document will be included in the attachments.

The selected contractor must provide all labor, materials, equipment, and certifications required to perform monthly, quarterly, semi-annual, and annual inspections, operational testing, preventative maintenance, and emergency repairs for fire protection and alarm systems at the following locations:

  1. USCG Sector San Diego: 2710 North Harbor Drive, San Diego, CA 92101 (Buildings A, B, C, D, E, F, G, H, I, and outside HAZMAT/flammable storage lockers).

  2. CG Moorings at Ballast Point / Naval Base Point Loma: Kerrick Rd. Bldg 5, San Diego, CA 92106 (Three buildings, dock, and storage areas).

Major Systems and Equipment Inventory:

  • Fire Alarm & Detection Systems: 6 Fire Alarm Control Panels (Silent Knight / Harrington Signal), 2 Annunciators, 190 Smoke Detectors, 17 Heat Detectors, and over 170 horn/strobe notification appliances.

  • Special Hazard Suppression Systems:

    • 6 Ansul IND-X Dry Chemical systems (HAZMAT/flammable storage).

    • 2 FM-200 clean agent systems (JHOC OPCEN & COMCEN).

    • 2 Chemguard C2 Foam systems (Hangars 1 & 2).

    • 1 R-102 Wet Chemical kitchen hood system with Range Guard and Gaylord Hood (Galley, Building B).

  • Water-Based Sprinkler Systems: 5 Wet/Dry Fire Main Sprinkler Systems (including 6 risers, flow/tamper switches, and pre-action activation systems).

  • Portable Fire Extinguishers: Inspection, testing, maintenance, and hydrostatic testing of approximately 143 portable fire extinguishers (varying sizes: 2.5 lb to 150 lb, ABC, BC, CO2, Halon, and Class K).

Key Performance & Qualification Requirements:

  • Certifications: All technicians performing scheduled maintenance, testing, and repairs must be certified by Silent Knight and Harrington Signal Inc. In addition, FAA and San Diego County Certifications will be required. Proof of certifications must be submitted prior to award.

  • Priority Response: The contractor must provide priority response for emergency trouble calls, arriving on-site within 24 hours or the next business day.

  • Documentation & Deliverables: Immediate written post-test documentation on company letterhead (detailing test results, pass/fail status, and discrepancies), updated physical system tags/stickers, and a comprehensive monthly maintenance calendar/spreadsheet.

INDUSTRY FEEDBACK & QUESTIONNAIRE

To assist the USCG in developing an acquisition strategy that aligns with the FAR Overhaul’s emphasis on flexible, performance-based, and fixed-price contracting, please provide direct, plain-language responses to the following questions:

A. Company Information

  1. Company Name, Address, Unique Entity ID (UEI) on SAM.gov, and Point of Contact (POC) information.

  2. Business Size Standard and Socioeconomic status (e.g., Small Business, SDVOSB, WOSB, HUBZone). 

B. Technical Capabilities & Qualifications

  1. Confirm if your firm possesses current, active certifications from Silent Knight and Harrington Signal Inc. to perform work on the specified control panels.

  2. Describe your firm’s capability to manage the diverse range of special hazard systems listed (FM-200, Chemguard Foam, Ansul IND-X, and R-102 Wet Chemical). Do you perform these services in-house or utilize subcontractors?

  3. What is your firm's standard mobilization time for emergency/unscheduled service calls in the San Diego/Point Loma area? Can you reliably commit to a next-business-day response?

C. Acquisition & Pricing Feedback

  1. Contract Type: Do you foresee any barriers to executing this SOW under a Firm-Fixed-Price (FFP) contract structure with pre-priced CLINs for emergency repairs?

  2. Risk Allocation: The SOW excludes repair coverage for "unusual or abnormal phenomena of the elements," "owner misuse/maltreatment," "vandalism," or "acts of aggression/war." Does this clear division of risk allow your firm to provide more competitive pricing without adding high-risk contingencies?

  3. Subcontracting Reporting: In compliance with the decommissioning of the Electronic Subcontracting Reporting System (eSRS), subcontracting plan reporting must now be processed via the Subcontracting Plan Reporting (SPR) system in SAM.gov. If applicable, does your firm have experience using this updated SPR interface?

4. Submission Instructions

Interested parties must submit their response in a streamlined, plain-language format to minimize administrative overhead.

  • Response Length: Recommended to be no more than 5 pages (excluding copies of manufacturer certifications).

  • Submission Deadline: Friday, 21 August 2026 - 7:00 am Pacific.

  • Submission Method: Electronic submission via email to the Contracting Officer at ryan.h.king2@uscg.mil

  • Questions: Technical or administrative questions regarding this RFI must be submitted by 19 August 2026 the USCGto provide consolidated, transparent answers to all interested participants.

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Documents

Files (1)

  • Fire Suppression Systems SOW.docx

    397 KBAdded in Sources Sought version 4Posted
    Download

Lifecycle

  1. 4
    Version 4Sources SoughtArchivedCurrent

    RFI - 37250PR260000091 - USCG Sector San Diego - FAA Regulated Hangar Fire System Testing, Certification, and Maintenance + Standard Fire Equipment and Systems Testing and Certification

    Notice 9c267915e382491ca7e822ab9b0065d4 on SAM.gov

  2. 6
    Version 6Special NoticeArchived

    Type changed from Sources Sought to Special Notice

    Determination and Findings IAW FAR RFO 12.102(a) and FAR Subpart 13.106-1(b) & Award Notice

    Notice 0458a9c497ea43b283673e8bc0249abd on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

37250PR260000091

Archive Date

Sep 5, 2026

Office Address

SAN PEDRO, CA, 90731