Notice ID: b40571c7dab44667957f3777caabc3e9Combined Synopsis/Solicitation
60 Klbf Universal Test Machine
Responses closed . Full description on SAM.gov.
Overview
- Response deadline
- 3:00 PM MDT
- Posted
- June 29, 2026
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 334519: Other Measuring and Controlling Device Manufacturing
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- AMC.ACC.MISSION INSTALLATION CONTRACTING COMMAND.419TH CSB.W6QM MICC-FT DRUM
- Place of performance
- US ARMY YUMA PROVING GROUND301 C STREET YUMA AZ 85365, 85365
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- W911S226U3510
- Notice ID
- b40571c7dab44667957f3777caabc3e9
Description
amended to include Set aside code. Model 68FM-300 Floor Mounted Materials Testing System, Force Capacity 300 kN (30,600 kgf, 67,500 lbf) Dual column oor mounted electromechanical testing system including:1. Integrated digital closed-loop control and data acquisition electronics including crosshead extension and load measurement channels (two optional strain channels can be added to software-based systems)2. Automatic recognition and calibration of transducers3. Pre-loaded balls crew drive and crosshead guidance system powered by a bush-less AC servomotor4. Ergonomic handset with two programmable soft keys, start, stop and return functions, variable speed jog and specimen protection5. User selectable system of units: SI, metric and US customary6. Operator protects architecture7. Auto positioning8. Collision mitigation9. Testing Speed Range 0.00005 to 560 mm/min (0.000002 in/min to 22 in/min)10. Crosshead return speed 640 mm/min (25 in/min)11. Type IIF LH (M48 x 2 threaded hole) base tting12. CE mark conformity10-Year Mechanical Systems Warranty English language option Tall Height Load Frame Support Base for Models 68FM-100 and 68FM-300 Load FrameHeight of testing platform is approximately 748 mm (29.4 in), which is 300 mm (11.8 in) over Standard Height. Provides shelf area with capacity rating of 100 kg 220 lbs. evenly distributed. 13. 1 Phase 208 VAC - North America Plug: NEMA L6-20P Maximum Crosshead Travel: 1359 mm (53.5 in)Total System Height for Standard Base: 2287 mm (90 in) Total System Height for Tall Base: 2587 mm (101.9 in) Horizontal test space 575 mm (22.6 in)System footprint (W x D): 1140 mm x 786 mm (44.8 in x 30.9 in) No Pneumatic Air Control Kit Static Load Cell: 300 kN (30,600 kgf, 67,500 lbf) - Type II 14. Tension and Compression15. Type IIF tting (M48 x 2 LH threaded hole)16. Bolt-on design with self identi cation and electrical calibrationSystem installation and training Installation performed by an Instron factory and eld trained Service Engineer Representative. The introduction system can be provided for up to 3 operators. For larger numbers of operators, Instron Training classes are recommended. Some or all the following activities will be performed subject to the system quoted and system con guration:a. Set up of systemb. Safety awareness and general testing safety precautionsc. Make all physical and electrical connections, except 3 phase power and waterd. Mount, install and test all peripheral xtures and transducers, environmental chambers, and any major accessories that are supplied with the systeme. Check correct operation of the system.f. Check correct operation of all electrical components and mechanical assemblies and transducers (where tted)g. Con gure controller and test for correct operation including all adjustments and tuning (includes Console software for Dynamic systems)h. General instruction associated with any hardware elements of the systemi. Review basic operation manuals and any other related documentationj. Calibration and veri cation services are quoted separatelyk. Basic System and Software instruction are quoted separately System Warranty ServicesThe service and support agreement for this system while under warranty includes the following services during the rst year of system ownership (see Instron Terms and Conditions for exact details, limitations and restrictions):a. Parts, labor and travel for repair/replacement for covered items (as de ned in terms and conditions)b. Priority telephone support during normal business hours at our Norwood MA headquarters.c. Direct Veri cation Remindersd. Software Update Noti cationse. Downloadable Software Updates via Instron Connect Software and Customer Portalf. Online Access to Calibration Certi cates and Service Historyg. System Diagnostics via Instron Connecth. Direct Screen Share with Voice via Instron Connecti. Augmented Reality (AR) App Supportj. AI-Driven Troubleshooting Tool via Mobile App and Instron Connect Portal Instron Connect Agreement for New Systems or Software Upgrades/UpdatesInstron Connect includes several technologies that create a secure connection between the testing systems at your facility and Instron. Our problem-solving tools harness innovative technology to rapidly troubleshoot issues and answer your technical questions, increasing productivity, reducing risk and minimizing downtime.Through the Instron Connect Software, Customer Portal, Mobile App and AR Support Tool, you can:k. Share your screen and system diagnostics data with Instron Technical Supportl. Receive calibration and service agreement reminders through the Connect softwarem. Send priority requests for technical support, calibration or on-site servicen. Download software updateso. Access calibration certi cates and service historyp. View your service agreementq. Self-diagnose and solve your system issues with the InSkill AI troubleshooting tool and mobile appr. Receive remote visual support through the AR Support Tool, bringing Instron?s technical support team eyes into your lab
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Links (4)
- PIEE Solicitation Module Link for W911S226U3510piee.eb.milPosted
- Web Based Training for the PIEE Solicitation Modulepieetraining.eb.milPosted
- Registration Instructions for the PIEE Solicitation Modulewww.acq.osd.milPosted
- Department of Defense Procurement Toolboxdodprocurementtoolbox.comPosted
Lifecycle
- 1Version 1Combined Synopsis/Solicitation
60 Klbf Universal Test Machine
- 2Version 2Combined Synopsis/Solicitation
60 Klbf Universal Test Machine
- 3Version 3Combined Synopsis/SolicitationCurrent
60 Klbf Universal Test Machine
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Reason for update is to change the set aside from N/ A to Total small business set aside. 1. LP6000 SYSTEM KIT-US Portable dual channels data acquisition base unit Detachable ruggedized controller LaserViewer Inspection Module-level 2, Soft key Wireless mouse Shipping case Documentation and manual kit AC Power cord US TYPE B 120V /10A AC Power Adapter for controller US TYP B 120V/10A FORUSE WITH LBIS /VBIS. Dimensions: 380 W x 200 H x 300 L [mm] (15 W x 8 H x 12 L [inch])Processor: Intel Core i7-1260P 12-Core/16-Thread 2.1 GHz Base/4.7 GHz TurboWeight: 12.4 Kg (27.3 lbs)Memory: 16GB DDR4 RAM; 3200 MHzPower: 110/240 VAC ? 50/60 Hz InternationalStorage (Internal)512GB PCIe 3.0x4 NVMe? SSDDisplay: Sunlight Readable Full HD LCD 13.3inch 1920x108 Environmental Specifications and CertificationsController UnitBase UnitOperating Temperature: -20?F - 145?F (-29?C - 63?C)Operating Temperature: Certified for 14?F - 122?F (-10?C - 50?C) per MIL-STD-810GHumidity: 95% RH, non-condensingHumidity: 0-90% non-condensing (equipment is not waterproof)IP Rating: IP66 certified IP Rating: Designed for IP54 MIL-STD-810H certifiedDrop and Vibration Certified per ASTM D4169 DC 13 Assurance Level II, Schedules A, E, F (within provided shipping case)MIL-STD-461G certified Vibration and 6 foot drop resistant2.Self-Propelled sensor delivery unit for 105-120mm camera/LVDT/LBIS? The SDU shall be capable of pushing or pulling the sensor 120mm sensors over an axial distance of no less than 8 meters (26.3 feet).? The SDU shall be provided with a muzzle adapter that is capable of being mounted to 105mm and 120mm gun tubes.? The SDU shall be capable of being interfaced with existing YPG-owned 105 mm and 120 mm LBIS (laser) sensors.? The SDU shall be provided with a flexible cable that includes a non-scratch protective cover.? The SDU shall be capable of allowing data acquisition over the full length of the 120 mm bore and up to the muzzle.? Linear resolution shall be 0.010? or better? Uni-directional position repeatability goal shall be 0.040? or better in | - | Combined Synopsis | 07/31/2026 |
1. Upgrade Partner to Bluehill Universal Testing Software a. English language option. b. Bluehill Universal for existing Partner license with 3300 controlled systems c. For 3300 Instron controller series d. Test Method Suite with Application Module Suite for New Purchase e. Test Profiler for Bluehill Universal g. Ethernet Frame Interface EFI. h. For connection to the test machine only. i. US and Canadian Power Cord Set to NEMA 2. Integration and Onsite Installation a. Instron Connect Agreement for New Systems or Software Upgrades/Updates b. Onsite Software Introduction to Bluehill Fundamentals and Test Method Development.1c. Travel and Logistics Fee for Tensile Service. 3. Operator Dashboard and Desktop Option a. Operator Dashboard for existing 3300 Series Systems b. 21.5 inch Touch Computer c. Operator Dashboard arm mounting for table model systems with extruded column covers and T-slots. d. US and Canadian Power Cord Set NEMA | - | Combined Synopsis | 07/24/2026 |
1.0 DescriptionThis equipment is required to be used with YPG existing Video Bore Inspection System and Laser Bore Inspection System measurement equipment, providing ultra-high-resolution UHR non-contact laser profilometry measurement for 155mm M776 and M284A2 cannon gun tubes. These specifications are required to ensure compatibility.2.0 Deliverables2.1 Qty 1, 155mm Large Caliber Laser Profilometry Scanner Assembly, UHR2.2 Qty 1, 155mm Large Caliber Calibration Ring, UHR3.0 Specification, 155mm Large Caliber Laser Profilometry Scanner Assembly, UHR3.1 Compatibility: must be fully compatible with existing VBIS, LVDT, and LBIS equipment, and shall support 155mm bore sizes.3.2 Key Specifications3.2.1 Axial Scan Resolution: Adjustable, 0.25 mm or 0.01 inch minimum3.2.2 Rotary Scan Resolution: Adjustable, 0.1 mm or 0.004 inch minimum3.2.3 Sensor Resolution: 0.005 mm or 0.0002 inch3.2.4 Measurement Repeatability: 0.012 mm or 0.0002 inch3.2.5 Measurement Accuracy ? Bore: Better than 0.012 mm or 0.0005 inch 3.2.6 Laser Power: less than 5 mW3.2.7 Laser Power Classification: IEC Class 3R3.2.8 Laser Spot Size: 0.025 mm or 0.0005 inch3.2.9 Laser Measurement Range: 152.43 ? 160.05 mm or 6.001 ? 6.301 inch 3.2.10 Centering Device Range: 149.5 ? 163.6 mm or 5.89 ? 6.44 inch4.0 Specification, Large Caliber Laser Profilometry Scanner Assembly4.1 Compatibility: must be fully compatible with existing VBIS, LVDT, and LBIS equipment, and shall support 155mm bore sizes.4.2 Key Specifications:4.2.1 Configuration: 3-step ring, with each step diameter within the Laser Measurement Range of the corresponding bore size scanner assembly4.2.2 Step Calibration Uncertainty: each step measured to better than 0.00005 inch or 1.27 m uncertainty4.2.3 Certification: NIST Traceable | - | Combined Synopsis | 07/24/2026 |
Amended to add set aside code. The proposed Coordinate Measuring Machine shall meet or exceed the following minimum requirements: 2.1 Machine Structure and Measuring Volume a. Fixed bridge or equivalent high-precision bridge-style Coordinate Measuring Machine. b. Measuring volume shall be no less than: X-Axis: 900 mm Y-Axis: 1,500 mm Z-Axis: 800 mm c. Machine shall utilize a tri-cision, thermally stable bridge construction or an equivalent structural design that provides equal or superior stiffness, geometric stability, and measurement performance. d. Machine shall include vibration damping technology or an equivalent vibration isolation solution suitable for a production inspection environment. 2.2 Performance Requirements. The CMM shall provide performance equal to or better than the following: a. Maximum volumetric measurement speed of not less than 510 mm per second. b. Maximum acceleration capability of not less than 1,700 mm per second . c. Length measurement error (MPEE) of 1.5 plus per 333 microns or lower in accordance with ISO 10360-2. d. Maximum permissible probing error (MPL) of 1.5 microns or less. e. Maximum permissible scanning performance (MPE THP) of 2.9 microns or less within a 45-second test cycle. Based on ISO1360 specifications. Equivalent performance metrics validated through recognized industry standards will be considered.2.3 Probe and Sensor Configuration a. Machine shall include a motorized articulating probe head capable of automatic indexing. b. Probe head shall provide indexing increments of 7.5 degrees or finer. c. System shall include an X1H scanning probe or an equivalent high-speed contact scanning probe capable of continuous surface data acquisition and precision feature measurement. 2.4 Controller Requirements a. Machine shall include an HH-C-V2.1 controller or a controller of equal or greater capability. b. Controller shall support high-speed scanning, automatic probe head operation, CAD-based inspection programming, fast probe mode and network integration. c. System shall include a DC241 motion control system operating on 115V power or an equivalent controller providing equal or greater functionality. 2.5 Thermal Compensation a. Machine shall include thermal compensation capability equivalent to Kit Clima Thermal Compensation Version 19 or newer. b. System shall provide automatic linear thermal compensation for both workpiece and scale measurements. c. Thermal compensation system shall continuously monitor environmental conditions and apply correction factors during measurement operations. 2.6 Air Preparation System a. Machine shall include an air dryer and filtration package compatible with 110V operation. b. Air preparation equipment shall be sized appropriately for continuous operation of the supplied CMM. 33. SOFTWARE REQUIREMENTS 3.1 Inspection Software a. System shall include PC-DMIS CAD plus 2 Version 2026.1 or newer, or an equivalent CAD-based metrology software platform. b. Software shall support: CAD model import and interrogation, GD and T evaluation, Automated inspection routines, Contact scanning applications, Report generation 3.2 Probe Management Software a. System shall include PC-DMIS Tip Changer Module Version 2026.1 or newer, or equivalent automated probe management functionality. b. Software shall support automatic probe qualification and probe exchange operations.4. FIXTURING REQUIREMENTS a. Contractor shall provide a modular fixturing system consisting of a minimum 30-inch fixture system and associated component kit. b. Fixturing system shall support flexible setup of prismatic and complex workpieces. 5. INSTALLATION AND ACCEPTANCE a. Contractor shall provide delivery, installation, startup, calibration, and operational checkout. b. Following installation, contractor shall perform a complete machine performance verification in accordance with ISO 10360-2 and -5 standards. c. Acceptance shall occur after successful completion of installation and documented verification testing.6. TRAINING REQUIREMENTS The contractor shall provide classroom-based operator and programmer training including a. One (1) PC-DMIS Level 1 training course or equivalent introductory metrology software training. b. One (1) PC-DMIS Level 2 training course or equivalent advanced metrology software training. Equivalent training programs shall cover machine operation, CAD-based programming, probe management, reporting, scanning, and advanced inspection techniques.7. WARRANTY AND SUPPORT a. Contractor shall provide a minimum one-year comprehensive warranty covering parts, labor, and travel. b. Contractor shall provide MyCare Premium coverage or an equivalent premium support program. c. Premium support shall include technical assistance, software maintenance updates, Machine Certification and priority service response. d. Offerors proposing alternate support programs shall clearly identify service levels and written response times and commitments. | - | Combined Synopsis | 07/02/2026 |
3 Machine Specific Requirements: The new Magnetic Particle Inspection Machine shall be capable of inspecting the outer surface and the internal surface of the 155mm M284, M776, M199 cannon breeches manufactured at the Watervliet Arsenal.3.1.1 General Physical Requirement: The Magnetic Particle unit complete with: ? Maximum current output 6,000 amps FWDC ? Demagnetization - Reversing DC ? 30in Head Opening ? Digital Ammeter with ?hold? feature ? Infinitely variable current control ? 30in Coil ? Stainless Steel Tank 58in L x 47in W, V shape stainless tank with sufficient pitch angle, mesh screens, and dust covers? Hardwood Grilles ? Foot switch operation ? air chuck ? Full Panels ? Louvered ? Hip Bar ? Powered rotary turn table 500 lb. capacity (safety payload up to 1500lbs.)? 30in diameter coil to be raised and lowered by manual pneumatic valve.? 2in diameter aluminum thru conductor to be raised and lowered by manual pneumatic valve. Thru conductor will manually pivot horizontally for rear storage after use. ? A overhead 500 lb. hoist/trolly will be supplied. ? Full curtain inspection enclosure with REL C4 magnum LED black light and 1000 CFM roof extraction fan. ? Accessory including Keto ring, keto ring CAL fixture, Gould-Bass MD-220 Hall Effect Magnetic Field Strength Meter, and 2 handheld cordless dual white / UV-A LED lights? Voltage 460VAC, 60HZ, 3 phase 200 Amps, Four - No. 4 AWG 3.1.2 Performance Characteristics Magnetizing Output Current (maximum): 6000 DC Control Setting: Infinite adjustment. Regulation: Electronic Rectification: Silicon Controlled Rectifiers (SCRs) Demagnetization Output DC Mode: 6,000 amperes (maximum) alternating polarity ramped to zero amperes Range of Automatic Timer DC Magnetization: 1/6 to 1 seconds ( second normal) DC Demagnetization: 15 to 40 seconds (30 seconds normal) Manual Timing: Manual operation (Remote cable must be used for manual timing) (Terminal cutout will disconnect unit if overheated.) Duty Cycle At 100% Rated Output: .5 seconds ON, 4 minutes OFF At 40% Rated Output: 10 seconds ON, 3 minutes OFF Thermal Cut Out: Disconnects unit if overheated Convenience Outlet: 115V AC, 60 Hz, 5 amperes Weight: 1150 pounds (approximate) Dimensions (Overall) Length: 136 inches Width: 111 inches Height: 112 inches 3.1.2 Detail Description 1. Constructed of a rigid steel framework with full louvered panel finish. 2. Maximum current output is 6,000 amperes FWDC in the conventional mode. 3. Complete with automatic reversing DC demagnetization. 4. Complete with (quick break) circuitry to ensure maximum residual field and maximum repeatability of inspection results. 5. Complete electronic controls including self-indicating plug-in modules for reliability and ease of maintenance. The electronic controls also provide a very fast response time of only 8 milliseconds, i.e. time taken for the magnetizing current to reach the desired level.6. Complete with infinitely variable, current control current selection between zero and maximum output. 7. Fitted with digital readout meter with L.E.D. display, accurate to 1%. This meter has a (hold and display) feature whereby the magnetizing current level is shown and held on display until the next magnetizing shot. The meter is also fitted with a current assurance light which illuminates to show magnetizing current flowing through the component. 8. On the control panel of the unit are mounted all the various switches for choice of current, magnetization or demagnetization, and for contact or coil method. 3.1.3. Conventional Magnetization or Demagnetization In the conventional mode parts can be magnetized in the longitudinal direction and the circumferential direction. The field is applied to the part by either clamping between the head and tail stock and firing a half second current shot through it, or by still retaining the part in the head and tail stock, moving the coil into position, and then energizing the coil. The conventional mode can be carried out with FWDC current.3.1.4 Enclosure: It shall block light such that the inside of the enclosure does not exceed 2 footcandles of brightness. The enclosure shall include a large ventilation fan. The enclosure shall come equipped with a white light, 2 handheld cordless dual white and UV-A LED lights that meet ASTM E1444 and E3022. A calibrated digital radiometer in accordance with ASTM E1444 and E2297-23 for measuring UV in w per cm visible light in foot candles shall be supplied. A main control panel with white light and fan control.3.1.5 Magnetic Particle Solution System: The machine shall come equipped with a minimum 30-gallon stainless steel tank for the magnetic particle solution. A pump system shall recirculate and agitate the solution such that the magnetic particles will not accumulate or settle during operation. The agitation system shall allow the magnetic particle solution to remain within 3% of theoretical level during an 8 hours continuous runtime. The machine shall come equipped with a fluid catch tray to collect the magnetic particle solution that is applied to the workpiece. The machine shall come equipped with a spray nozzle/hose located in the inspection enclosure. The spray nozzle shall be hung above the catch tray when not in use. The magnetic particle solution shall not spill or splash onto the floor during normal operation. The machine shall have a secondary catch pan to catch fluid in case of a leak in the main catch pan. This pan shall have a readily accessible drain but does not need to tie into the recirculation system.3.2 Machine Control System: The machine?s control system shall be located within the inspection enclosure and at the inspection area. 3.2.1 Control Features: ? Machine On Off using the emergency stop button.? Emergency Stop? Workpiece Magnetization/Demagnetization? Pump System On Off? Fan On/Off? White Light On Off? Digital Current Meter Display on control panel.? Infinitely Variable Current Control? Adjustable Shot Time 3.1 Safety Features: E-Stops at inspection station area of machine3.3.2 Digital Current Meter Display: The digital current meter display shall be accurate to 10%. The meter shall have a ?hold and display? feature that displays the magnetizing current level until the next magnetizing shot. The meter shall be fitted with an indicator light that illuminates to show when magnetizing current has flowed through the workpiece.3.3.3 Diagnostic Capabilities: the machine unit shall be equipped with diagnostic capabilities covering the mag control boards.3.4 Requirements for Demonstration of Conformance:3.4.1 Certification of Completeness: The contractor shall provide written certification that the machine is complete, has been properly calibrated, and visually examined for appearance, workmanship, maintainability, and completeness, including all specified system, and accessories.3.4.2 Test of Conformance to Specified Workpiece: The contractor shall perform a magnetic particle inspection on a cannon breech if requested. The machine shall be observed for proper function and compliance with the requirements of this specification. 3.4.3 Additional Testing: If requested the contractor will demonstrate or verify the machine compliance with any requirement in this specification.3.4.4 Provision of Materials and Equipment for Preliminary and Final Acceptance Testing:3.4.4.1 Workpieces: All workpieces to be tested as required in paragraph 3.4.2 shall be provided by Yuma Proving Ground.3.4.4.2 Magnetic Particle Solution: The magnetic particle solution shall be provided by the contractor for the preliminary acceptance and by Yuma Proving Ground for final acceptance.4 Quality Assurance Provisions:4.1 Responsibility for Inspection: The contractor shall be responsible for performing all certifications and tests required in paragraph 3.4 and shall provide such materials, supplies and equipment as specified.4.2 Preliminary Acceptance Inspection: Preliminary acceptance inspection by Yuma Proving Ground level 3 NDT expert shall occur at the contractor?s facility prior to machine shipment to Yuma Proving Ground and shall consist of the certifications and tests specified in paragraph 3.4. When the certification of conformance is completed, the contractor shall provide no less than 15 calendar days notice to the Yuma Proving Ground Contracting Officer that the machine is ready for the preliminary acceptance inspection.4.2.1 Re-inspection Provisions: If, during the course of preliminary acceptance inspection deficiencies are disclosed which cannot be satisfactorily corrected during this visit, preliminary acceptance will be withheld and the contractor will be required to take corrective actions. In such cases, the Yuma Proving Ground POC reserves the right dispatch Yuma Proving Ground representatives to observe a re-inspection. 4.3 Final Acceptance Inspection: Final inspection and acceptance of the machine shall be after installation at Yuma Proving Ground. At this time the machine shall again be subjected to, and required to pass, the test procedures specified in paragraph 3.4. 4.4 Warranty: Upon final acceptance of the machine a Standard Commercial Warranty shall commence for the duration of a one-year warranty covering parts and labor and five-year warranty covering Frame and Tank to include as a minimum, parts and labor for the duration of the warranty, at no cost to the Government. The 1-year period shall commence from the date of notification by the Contracting Officer of the final acceptance. Final acceptance is defined as the act of an authorized representative of the Government, by which the Government assumes ownership of existing supplies/equipment and/or approves specific services rendered, as partial or complete performance of the contract (i.e. testing, training, and delivery of all required technical documentation). 5 Preservation, Packaging and Delivery Instructions: The contractor shall utilize standard commercial methods of preservation and packaging appropriate for machine tools and acceptable to commercial carriers. As a minimum, all areas susceptible to damage from exposure to the elements shall be preserved and/or packed to prevent damage. The machine and equipment shall be blocked, braced and skidded to prevent damage during transport and to facilitate handling, loading and unloading. The contractor shall be responsible for ensuring that the machine and equipment are delivered to Yuma Proving Ground in good condition and shall retain this responsibility until the machine and equipment are offloaded at Yuma Proving Ground by the responsible parties. | - | Combined Synopsis | 07/03/2026 |
Additional Details
Solicitation Number
W911S226U3510
Archive Date
Jun 29, 2027
Office Address
FORT DRUM, NY, 13602-5220