GovChime
Notice ID: ba93080c30c3430a93a2c3f7bde7038fCombined Synopsis/Solicitation

3D Foot Scanner for Boot Fitting

Responses closed . Full description on SAM.gov.

Overview

Response deadline
6:00 PM EDT
Posted
September 16, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Small Business Set Aside - Total
NAICS
339999: All Other Miscellaneous Manufacturing
Agency
Department of WarDepartment of the Army

Notice details

Office
AMC.ACC.MISSION INSTALLATION CONTRACTING COMMAND.419TH CSB.W6QM MICC-FT DRUM
Place of performance
Room 143, BLDG 10400Leaders Training Brigade10400 Tank Hill PkwyFort Jackson, SC 29207, 29207
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W911S226U4505
Notice ID
ba93080c30c3430a93a2c3f7bde7038f

Description

amended to change PSC Code and NAICS Bottom Line Up Front (BLUF)The Brigade requires the procurement of ten (10) commercial-off-the-shelf (COTS), brand-agnostic Automated 3D Digital Footwear Fitting Systems and associated annual technical service. This acquisition modernizes the Initial Entry Training (IET) Clothing Initial Issue Point (CIIP) across the Reception Battalions. It directly addresses initial issue throughput constraints, eliminates manual sizing inaccuracies, and mitigates preventable lower-extremity musculoskeletal injuries (MSKIs) among incoming trainees.Operational JustificationReception Battalions process thousands of trainees per cycle under stringent processing timelines. Traditional manual measurement devices are prone to significant operator error, fail to capture volumetric dimensions and arch compression under load, and regularly lead to improperly fitted combat footwear. Ill-fitting boots remain a primary driver of preventable sick call visits, cellulitis, severe blister friction, and training pipeline attrition during Basic Combat Training (BCT) and One Station Unit Training (OSUT). Implementing an automated digital system allows duty personnel to capture comprehensive foot dimensions in under 20 seconds per soldier, ensuring objective, repeatable fit accuracy that protects force health and training timelines.Salient CharacteristicsTo maintain full and open competition, the solicited systems must operate using non-invasive optical or sensor-based 3D surface scanning that measures standing volumetric foot dimensions under standard body weight. The units must capture dual-foot length, width, arch height, heel width, ball girth, and pressure distribution within a single scan cycle not exceeding 20 seconds. Systems must incorporate automated sizing algorithms that directly convert millimeter scan data into standard military combat boot sizing across all standard lengths and widths (Narrow, Regular, Wide, and Extra Wide). Additionally, each unit must feature a self-contained, ruggedized platform built for high-tempo daily recruit volume, an intuitive touchscreen interface for operators, and continuous software support and diagnostic calibration capability.Unit Distribution and Operational ContinuityThe ten requested systems will be allocated based on trainee reception volume and mission continuity requirements. The 120th Adjutant General (AG) Battalion will receive four (4) systems to support its high-volume throughput requirements. The 30th, 43rd, and 95th AG Battalions will each receive two (2) systems to outfit their primary CIIP processing stations. The final system will be assigned to the Brigade/LTB headquarters as an operational reserve float. This designated spare ensures that any unexpected hardware malfunction, maintenance cycle, or recalibration event at a subordinate reception battalion can be addressed immediately without disrupting intake schedules.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Lifecycle

  1. 1
    Version 1Combined Synopsis/Solicitation

    3D Foot Scanner for Boot Fitting

    Notice c185c3dc2c274ea79c7cacf15ad13392 on SAM.gov

  2. 2
    Version 2Combined Synopsis/SolicitationCurrent

    3D Foot Scanner for Boot Fitting

    Notice ba93080c30c3430a93a2c3f7bde7038f on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Reason for update is to change the NAICS from 922160 to 339999 Balaclava, Hood Flame resistant. a. Arc Rating: 42 cal/cm2 b.CAT 3 c. Fabric/Material: 6oz OPF Blend Knit d. Double Layer Top and Bib, e. Full head and facial protection extends below neckline f. Designed for use with arc goggle g. Lightweight, durable and breathable h. Flat seams designed for comfort i. Inherently flame resistant, FR protection will not wash or wear out j. FR fabric will not melt, drip or ignite k. Size: One size fits all l. Color Olive Drab Green or Black, m. Gender: unisex n. Moisture wicking and quick drying
-Combined Synopsis11/10/2026
amended to change NAICS code. Fire pump system
-Combined Synopsis11/10/2026
amended to change NAICS code. Zippers
-Combined Synopsis11/10/2026
amended to add set aside code and to change NAICS code. 6l capacity Autonomous Portable blood Refrigeration Unit
-Combined Synopsis10/22/2026
567 Tar Shield Salient Characteristics for Matrix: The contractor shall furnish and deliver one (1) splash shield partition room meeting the following minimum salient characteristics: Metal Frame Tubing: 5 ft -0 inches W 2 inches x 4 inches. One tube for top and one tube for bottom. Metal Frame Tubing for Curtain Areas:16 ft -0 inches W 2 inches x 4 inches. One tube for top and one tube for bottom.16 ft -0 inches W 2 inches x 4 inches One tube for top and one tube for bottom. No Ceiling with the partition room. Angle-iron frame, finished with gray powder coating. Two doors each to be equipped with a keyed cylinder lock on door. FOR FULL PANELS Overall partition height of 8 feet, 5 inches with minimum 4-inch open clearance on the bottom of all panels except the doors. Each Panel shall be in width of no more or no less than: 1/4-inch-thick clear polycarbonate.2 ft 0 inches Panel5 ft 0 inches Top and Bottom Tube9 ft 0 inches Panel 10 ft 0 inches Panel3 ft 7 inches Door1 ft 9 inches Panel7 ft 6 inches Panel 7 ft 0 inches Panel8 ft 0 inches Panel 10 ft 0 inches Panel 10 ft 0 inches Panel6 ft 0 inches Panel5 ft 4 inches Panel 10 ft 0 inches Panel8 ft 11 inches Panel3 ft 7 inches Door Material shall be delivered to the Government-designated location. Government-furnished / not included: Industrial sliding curtains for the two Section #6 openings. Strip door for the Section #9 opening. Purchase only, no install requested. The cited vendor quote identifies the partition as a single room with polycarbonate panels and a door, with the above framing, finish, height, and lock requirements.
-Combined Synopsis10/06/2026

Additional Details

Solicitation Number

W911S226U4505

Archive Date

Sep 16, 2027

Office Address

FORT DRUM, NY, 13602-5220