GovChime
Notice ID: c16cb6496edd4a6a86cef50de39289ccCombined Synopsis/Solicitation

DROP STATION

Responses closed . Full description on SAM.gov.

Overview

Response deadline
3:00 PM CST
Posted
February 17, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
333923: Overhead Traveling Crane, Hoist, and Monorail System Manufacturing
Agency
Department of WarDepartment of the Army

Notice details

Office
AMC.ACC.MISSION INSTALLATION CONTRACTING COMMAND.419TH CSB.W6QM MICC-FT DRUM
Place of performance
McAlester Army Ammunition Plant; 1 C-Tree Road Building 6, McAlester, OK 74501, 74501
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W911S226U2475
Notice ID
c16cb6496edd4a6a86cef50de39289cc

Description

Update 0003 is for Extending the due date Southern Systems Industrial Conveyors Mark No. 12402-WA96-1.5.7Loader Drop Rail Section with Stop Assembly The loader drop rail section with stop assembly includes the rail transfer section to bridge the monorail gap, position locking hardware and controls, lift arm connection and engagement, and the pushout connection to fully utilize all aspects of the system. This item is part of the existing monorail system, and all components and controls must integrate seamlessly to fully function the system. The load rating must match the existing unit as well (2,000 lbs.) with a standard F.O.S., and the trolley type and corresponding wheel profile must offer seamless movement at the monorail transition points. The original job that this was manufactured from at Southern Systems Industrial Conveyors is M-12-402-E.Note: To include pneumatic tubing and fittings

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Lifecycle

  1. 1
    Version 1Combined Synopsis/Solicitation

    DROP STATION

    Notice 6176d323a0434a1a97b6d368befce2a5 on SAM.gov

  2. 2
    Version 2Combined Synopsis/Solicitation

    DROP STATION

    Notice ea6309d604b545edbc31f217d1bd2c44 on SAM.gov

  3. 3
    Version 3Combined Synopsis/Solicitation

    DROP STATION

    Notice 0cac4781d46d4d62a04251f9addb77d5 on SAM.gov

  4. 4
    Version 4Combined Synopsis/SolicitationCurrent

    DROP STATION

    Notice c16cb6496edd4a6a86cef50de39289cc on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Salient CharacteristicsItem: Pneumatic Chain Hoist Assembly, Lug-Mounted.Brand Name or Equal To. Cisco-Eagle SKU TCRP-1627048 reference model TCRP2000P2.Quantity 2 eaches.1. Required Function. The contractor shall furnish one new, complete, commercially available pneumatically chain hoist assembly for lifting and vertically positioning loads in an overhead lifting application. The offered item shall be fully functional upon delivery and include all components identified below that are necessary for normal operation.2. Mandatory Salient Characteristics. The offered hoist assembly shall meet all of the following minimum requirements:CHARACTERISTIC. MINIMUN GOVERNMENT REQUIREMENTType. Pneumatically powered chain hoist assembly.Rated lifting capacity. Minimum rated capacity of 2 short tons i.e. 4,000 lb.Lift height. Minimum 10 foot vertical lift.Mounting configuration. Lug mounted configuration.Bottom hook. Furnished with a standard bottom hook suitable for the offered hoists rated capacity.Pendant control. Furnished with a pendant control. Pendant length shall be 7.5 feet, measured from the hoist, control connection point to the pendant control, or equivalent length necessary to provide the same operating reach.Chain container. Furnished with a canvas chain container sized to safely contain the full length of load chain associated with the required 10 foot lift.Structural, track interface. The assembly shall be compatible with the Governments existing flange, track interface identified as a 4 inch flange configuration with an applicable flange range of 3.23 inches through 6.02 inches. The vendor shall identify the specific mounting/trolley/interface dimensions of the offered item and certify compatibility with this requirement.Condition. New. Current-production equipment; used, refurbished, remanufactured, or demonstrator equipment is not acceptable.Completeness. Furnished as a complete operational assembly, including the hoist, required mounting/interface components, bottom hook, pendant control, and chain container.Documentation. Furnish manufacturer product literature, dimensional information, installation instructions, operating instructions, maintenance information, rated-capacity information, and warranty documentation.Identification Hoist shall bear permanent manufacturer identification and rated-capacity marking.The reference item identifies the item as a TCRP2000P2 hoist with a 2-ton capacity, 10-foot lift, lug mounted, standard bottom hook, 4 inch Flange 3.23-6.02 inch Flange Range, canvas chain container, and Standard-to-Lift Pendant Length - L = 7.5 ft.3. Offeror Submission RequirementsTo be considered technically acceptable, the vendor shall provide the following with its quotation.Manufacturer name and exact manufacturer part number for the item offered.Manufacturer descriptive literature, specification sheet, and dimensional drawing sufficient to verify:Rated capacity.Lift height.Lug-mount configuration.Bottom-hook configuration.Pendant length.Chain-container material and capacity andCompatibility with the stated 3.23-6.02-inch flange, interface range.If proposing an equal product, clear identification that the product is an equal product, rather than the referenced item.Warranty terms and the name and address of the warranty service point of contact.Proposed delivery lead time and shipping terms.Offerors proposing an equal product shall identify the offered make, model and provide descriptive literature or other adequate descriptive data showing that the item meets the solicitations salient characteristics.4. Technical Acceptability Language. Technical acceptability will be evaluated on a pass/fail basis. The quotation will be considered technically acceptable only if the offeror provides sufficient documentation demonstrating that the offered item meets every mandatory salient characteristic. Failure to provide adequate supporting documentation may render the quotation unacceptable.5. Delivery and Acceptance Language. Delivery shall be F.O.B. Destination to the delivery location identified in the solicitation. The Government will inspect the item upon delivery for quantity, visible shipping damage, completeness, manufacturer identification, rated-capacity marking, and compliance with the quoted make and model and required salient characteristics. Acceptance is contingent upon satisfactory inspection and verification of required documentation.
-Combined Synopsis11/13/2026
Hammar Spreader Beam
-Combined Synopsis11/12/2026
Hoist Stand
-Combined Synopsis09/24/2026
High Performance ELIMINATOR
-Combined Synopsis08/06/2026
Outdoor Motorized Gantry Crane
-Combined Synopsis07/07/2026

Additional Details

Solicitation Number

W911S226U2475

Archive Date

Feb 17, 2027

Office Address

FORT DRUM, NY, 13602-5220