GovChime

Research Triangle Park Forestry Sciences Laboratory HVAC Repair

Overview

Response deadline
5:00 PM EST
Posted
November 20, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Small Business Set Aside - Total
Agency
Department of AgricultureFOREST SERVICE

Notice details

Office
SOUTHERN RESEARCH STATION
Place of performance
Durham, North Carolina, 27713
Last updated
Nov 20, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
1240BE27Q0025
Notice ID
c21abfebfc5d4ee1a6b74dffe96d5bdf

Description

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12.  This announcement constitutes the only solicitation.  Quotations are being requested and a separate written solicitation will not be issued. 

Solicitation number 1240B27Q0025 is issued as a Request for Quotation (RFQ) for Research Triangle Park Forestry Sciences Laboratory HVAC Repair

This acquisition  is set-aside for small business concerns.  The applicable North American Industry Classification Standard Code is 238220  The small business size standard is $19 M  This acquisition is a Total Small Business Set-Aside.  All responsible sources may submit a quotation which will be considered by the agency. 

The primary HVAC system (ACCU-1/VRV 2-7) for the Forest Science and Assessment Center (FSAC) is a Mitsubishi VRF system (BHM06227, Model PURY-P120TLMU-A, Serial 79W00897, 10 tons, R-410A) with 6 interior units. The system does not maintain condition set points and an initial evaluation during a preventative maintenance service call diagnosed with a potentially significant refrigerant leak.

The Forestry Science Laboratory (FSL) building’s Fan Coil Units (FCUs) are redundant in the current HVAC system. The outside air vents are no longer needed and are introducing unconditioned air into the building. During cold weather, this can lead to the coils potentially freezing and have led to the freeze-stats tripping, resulting in nuisance shutdowns.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Files (2)

  • C04-1 1240BE27Q0025 Schedule and Statement of Work.pdf

    1.1 MBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • C04-2 wagerates.pdf

    4.1 MBAdded in Combined Synopsis/Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationCurrent

    Research Triangle Park Forestry Sciences Laboratory HVAC Repair

    Notice c21abfebfc5d4ee1a6b74dffe96d5bdf on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

1240BE27Q0025

Archive Date

Dec 16, 2026

Office Address

ASHEVILLE, NC, 28804