Notice ID: d5fa0a97c76b457fbdd9e4be0c98b732Award NoticeAwarded
Architect-Engineering Supplemental Services Federal Bureau of Prisons - Noth Central Regional Office
Awarded on November 4, 2026. Full description on SAM.gov.
Awarded tounder 15BBNF27D40000002 (source: SAM.gov award notice)• $7.5M
Overview
- Posted
- November 4, 2026
- Notice type
- Award Notice
- Set-aside
- No Set aside used
- NAICS
- 541310: Architectural Services
- Agency
- Department of JusticeFEDERAL PRISON SYSTEM / BUREAU OF PRISONS
Notice details
- Office
- FAO
- Place of performance
- Kansas City, Kansas
- Last updated
- Nov 4, 2026
- First published
- Last updated on SAM.gov
- Award date
- Nov 4, 2026
- Award amount (SAM.gov award notice)
- $7.5M
Identifiers
- Solicitation number
- 15BBNF27D40000002
- Notice ID
- d5fa0a97c76b457fbdd9e4be0c98b732
- Award number (PIID)
- 15BBNF27D40000002
Description
Award notice to Solicitation 15BBNF26R00000001.
Award Overview
Award Number
15BBNF27D40000002
Award Amount (SAM.gov award notice)
$7.5M
Award Date
Nov 4, 2026
Awardee
Awardee UEI
HBK4ZHMRRS95
Awardee CAGE Code
03FL4
Awardee Address
Lenexa, KS 66219, UNITED STATES
Original Solicitation
Notice ID: d5fa0a97c76b457fbdd9e4be0c98b732
Posted Date: Nov 4, 2026
Original Response Deadline: Not specified
More From This Vendor
Top 5 most recent
- $167.4KSigned Dec 2, 2025
- —Signed Jan 30, 2025
- $568.8KSigned Dec 4, 2024
- $127.0KSigned Nov 26, 2024
Contacts
Contracting Officer
Primary Contact
Documents
No documents available.
Lifecycle
- 1Version 1Award NoticeCurrent
Architect-Engineering Supplemental Services Federal Bureau of Prisons - Noth Central Regional Office
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Architect-Engineering Supplemental Services Federal Bureau of Prisons - Noth Central Regional Office Award notice to Solicitation 15BBNF26R00000001. | - | Awarded | Open |
*10/21/2026- Amendment posted of Questions and responses posed by contractors. Submission due date reemains the same. THIS IS A SYNOPSIS OF PROPOSED CONTRACT ACTION. FOLLOW THE INSTRUCTIONS CONTAINED IN THIS NOTICE FOR RESPONDING TO THIS OPPORTUNITY. The Federal Bureau of Prisons (FBOP), Central (CO), anticipates the need for indefinitedelivery indefinite-quantity (IDIQ), firm fixed-price contracts for supplemental architect-engineer (A-E) services, with a one (1) year base requirement and up to four (4) unilaterally exercised option years, with a possibility for a six-month extention as well. The Government is not obligated to exercise any of the option periods. While the Government anticipates multiple awards, no more than four (4) awards are expected. The services will be for various FBOP facilities throughout the United States. See the Statement of Work attachment for description of services. Most projects will take place in a fully occupied, fully operational, secure correctional environment. Most projects require complex design effort and detail along with extensive coordination between design disciplines, the institutions, and Central Office during design and construction. Firms are to perform services as required by the issuance of individual task orders. The guaranteed annual minimum amount of each contract is $10,000.00 and the estimated annual maximum is $10,000,000. The North American Industrial Classification System (NAICS) code applicable to this requirement is 541310 (Architectural Services). Interested firms must be registered in the System for Award Management (SAM) at https://SAM.gov. This requirement will be fulfilled pursuant to the Federal Acquisition Regulation (FAR) 36.6 and the Brooks Act. Pursuant to FAR Deviation 36.201(b), for any firm(s) receiving award under this requirement, no construction contract may be awarded to the firm (including any of its subsidiaries or affiliates) that designs the corresponding project Firms having the capabilities to perform the services described in this announcement are invited to respond by submitting Parts I and II of the Standard Form 330 (Architect Engineer Qualifications) dated not more than 12 months before the date of this synopsis. The current version of the form along with any extra pages/sections may be retrieved from www.gsa.gov/forms (Type in "SF330" in the Form Name or Number block for a full listing of the associated forms. *** Include a cover letter detailing your firms name and main office address (as registered in sam.gov), UEI#, Tax ID# (TIN), CAGE code, and main point of contact for your firm through out the solicitation process (phone and e-mail). Submissions should be on standard 8.5'' x 11" format. No extraneous attachments. Selection criteria will be based on the following evaluation factors in descending order of importance: Specialized Experience and Technical Competence (32%) Capacity to Accomplish the Work in the Required Time (demonstrated ability to complete projects on time) (27%) Acceptability of an Established Team of Key Personnel (23%) Professional Qualifications Necessary for Satisfactory Performance (including licensed engineers and architects licensed Nationwide)(18%) Submit details (maximum of one page per project) of not more than five significant and/or complex renovation projects completed in the past five years (Utilize Section F of the SF-330). Identify the lead designer and address the design approach with salient features for each project. Discuss how the client's program, function, image, mission, economic, schedule and operational objectives were satisfied by the overall design/planning solution. Include tangible evidence where possible such as certificates, awards, peer recognition, etc., demonstrating design excellence. Provide a client reference contact for each project, including name, title, address, phone, fax, and email. Submit resumes of key personnel outlining commitment to projects and qualifications and relevant experience as individuals and as a team. Highlight sustainability features incorporated into the project design (e.g., energy/water efficiency, waste reduction, use of recycled materials). Submit a narrative outline of not more than one page describing the firm's project management planning, coordination, scheduling and production facilities, capabilities, and techniques for both design and construction inspection (Utilize Section H of the SF-330). Submit a narrative outline (maximum one page) with examples describing the firm's ability to evaluate/develop accurate preliminary project budgets, ability to control project costs during design process, ability to design within funding limitations, methods used to coordinate construction documents, work of various engineering disciplines, and provide general production quality control (Utilize Section H of the SF-330). No fax or paper submissions. Submit electronically through the JEFS APP BOX at link below: https://jefs.app.box.com/f/336fbbe977394048827a238f901db3a3 All submissions should be in Adobe format. Title the file in the following format: 15BBNF26R70000006_ Company Name_SF330 Architect Engineer (A/E) Services for Central Office Electronic copies of each submission shall be compatible with the following software products: Adobe Acrobat Reader 11 and Microsoft Office Suite 2016. Narrative portions of the submission shall be in Adobe Acrobat portable document file (pdf) searchable text format. The Submitter shall not embed sound or video (e.g., MPEG) files into the submission files. Electronic files shall be clearly identified for each volume, section, and item. The Submitter must ensure electronic files are virus-free and shall run an anti-virus scan before submission. Submissions by mail or hand carried will not be evaluated. All responses must be received no later than Wednesday, November 4, 2026, 10:00 AM MST. It is the responsibility of the Submitter to confirm receipt by contacting Alex Jackson, Contracting Officer, at a4jackson@bop.gov. Failure to submit all required information may result in rejection. All submissions received after the exact time specified for receipt shall be treated as late submissions and will not be considered except under facts and circumstances allowed by the Federal Acquisition Regulations (FAR). Based on these submissions, a short-list of no more than six (6) firms will be selected for an interview. Firms should be prepared to discuss their submittals and to demonstrate their ability to fulfill the contract requirements. Final selection will be based on SF-330 submissions and interviews. After the SF-330 review and interview process, four (4) selected firms will be invited to submit a formal proposal and must be prepared to negotiate overhead, profit, and hourly rates for anticipated disciplines for use in negotiating firm-fixed-price contract rates as well as firm-fixed-price task orders to be completed under the contract. All contract awards and task orders thereunder are subject to a determination of fair and reasonable pricing. This acquisition is 100 percent small business set-aside. Firms must be registered in SAM.gov as a small business (see FAR provision 52.219-1 in the Representations & Certifications section of the SAM registration. If you have questions about SAM.gov, Government procurements in general, or need assistance in the preparation of your bid/proposal/offer, a local Procurement Technical Assistance Center (PTAC) may be able to help. The Procurement Technical Assistance Program was authorized by Congress in 1985 in an effort to expand the number of businesses capable of participating in the Government marketplace. To locate a PTAC near you, go to http://www.aptac-us.org. | - | Pre-Solicitation | 11/04/2026 |
Modification 2 to Presolicitation Notice 36C25527R0007, P/N 657-27-209JB, Project Title: Renovate Building 1 and 53 Main Lobbies. This modification provides answers to RFIs received, revised evaluation criteria and revised supplement B per below RFIs. The SF330 submission due date is extended from November 10, 2026 to November 16, 2026. RFIs Received with VA Responses in blue text: Construction Budget questions: Is that the Estimated Cost of Construction or the maximum for the A/E Design Fee? Estimated Cost of Construction If the $949,026 is the construction budget, this appears low in today's environment given that over 6,000 SF needs to be renovated. Can the VA please re-evaluate this budget and provide an update? The construction budget that was originally used in the supplement B pre-solicitation notice is incorrect. A revised supplement B is attached, changing the construction cost estimate from $949,026 to $725,873. The Construction budget is set and cannot be changed until the design process is underway. Key Personnel questions: The Presolicitation Notice lists: Supervisory, Fire Protection Engineer, Certified Professional Industrial Hygienist, and Life Safety Engineer. The Statement of Work and Supplement B list: Communications (voice/data), Interior Design, VPIH, Plumbing (including fire protection), and a 3rd Party Fire Protection Review. Questions: Which positions require resumes in Section E? What is the intended role of "Supervisory"? Per the SOW & Supplement B the following positions require resumes: Project Manager, Architectural, Mechanical, Electrical, Communication (voice data) Plumbing (Including Fire Protection), Structural, Interior Design, VPIH, Cost Estimator and a 3rd Party Fire Protection Review. Project manager is Supervisory Industrial Hygienist/Asbeston Project Designer: Question: Is an ABIH Certified Industrial Hygienist (CIH) acceptable for this position, and does a CIH satisfy the requirement for the VPIH and the state-accredited Asbestos Project Designer? If these must be separate individuals, should both be identified in the SF330? A CIH satisfies the requirement for the VPIH and the state-accredited Asbestos Project Designer. They can be the same individual. Site Visit: Supplement B, page 6, Section III.6.g: the A/E "shall meet with the COR at the proposed project site" prior to submitting a response Presolicitation Notice, page 4: "Personal visits to discuss this announcement will not be allowed" and only "the most highly rated firm must physically come to the site" before pricing Question: Please confirm that no site visit is required before the SF330 submission. No site visit is required prior to SF330 submission. Laboratory and Special Room Rquirements: Presolicitation Notice, page 7, Evaluation Criteria 2, Specialized Experience and Technical Competence: "laboratory requirements for the firm" Supplement B, page 18, Section B6.II.1: "floor plans of special rooms such as the endoscopy suite, recovery room, etc." Questions: Neither a laboratory nor an endoscopy suite or recovery room appears in the project scope. Do any of these requirements apply to this project? These requirements do not apply to this project. Can the VA please release updated and corrected documents? The evaluation criteria 2 will be changed to remove laboratory requirements for the firm and the COR will revise Supplement B to remove the endoscopy suite and recovery room from the Supplement B. | - | Pre-Solicitation | 11/16/2026 |
| - | Awarded | Open | |
| - | Awarded | Open |
Additional Details
Solicitation Number
15BBNF27D40000002
Archive Date
Nov 19, 2026
Office Address
GRAND PRAIRIE, TX, 75051