Steel and Other Metal Materials for the Marietta Repair Station: Stamford De-Watering Box Material PH 1
Active, responses due . Full description on SAM.gov.
Description
This procurement is for one (1) firm-fixed price commercial supply contract for the Marietta Repair Station to procure steel materials to complete work on Stamford De-Watering Box. The work includes providing the listed steel and other materials using NAICS code 332312 and PSC 9520.
1.1 Material: ASTM 1018 CR round bar.
1.a 6 1/2” dia round, 8’ long qty 6
2.1 Material: ASTM A434 CL bc (Q&T).
2.a 4” dia solid, 8 ft long, qty 20
3.1 Material: ASTM A53 Seamless pipe
3.a 1 ½” Dia Sch 40, qty 500 ft
3.b 3” dia Sch 40, 20 ft in length qty2
4.1 Material: ASTM 1026 tubing seamless
4.a 8” dia, 1.125 wall thickness, 20 ft long qty 1
5.1 Material: ASTM A36
5.a 1” dia round solid, 20 ft long, qty 2
5.b 2” flat bar, ½” thick, 20’ long. qty 2
5.c 2 1/2” flat bar, ½” thick, 20’ long, qty 4
6.1 Material: ASTM 709 Gr 50 for zone 2 (Plate)
6.a ¾” thick 4’ wide 8’ long qty 18
6.b ½” thick 4’ wide 8’ long, qty 28
6.c 1” thick 5’ wide 10’ long, qty 8
6.d ¾” thick 5’ wide 10’ long, qty 4
7.1 Material: ASTM A709 Gr 50 for zone 2, T-Beam
7.a WT 7x37, 20’ long, qty 12
8.1 Material: ASTM A709 Gr 50 for zone 2, Flat bar
8.a 4” thick, 10” wide, 10’ long, qty 30
8.b 1” thick, 25” wide, 10’ long, qty 30
8.c 2” thick, 3” wide, 10’ long, qty 30
8.d ¼” thick, 2” wide, 10’ long, qty 30
9.1 Material: ASTM A36
9.a ¼” thick, 4’ x 8’ plate, qty 25
9.b ¾” thick, flat bar 3” wide, 20’ long, qty 4
9.c 3/8” thick, flat bar 3” wide, 20’ long, qty 4
10.1 Material: ASTM 709 Gr 50 for zone 2,
10.a Rolled Skin plate with weld bevels marked in yellow in the attached drawings.
11.1 Material: ASTM 709 Gr 50 for Zone 2.
11.a Seal Bar shapes and qty is attached in drawings.
12.1 Fasteners: ASTM A325
12.a 1” dia 8, TPI, 8” length
12.b 1” dia DTI, Washers, qty 500
12.c 1” dia 8, TPI, Heavy Hex Nut, qty 500
12.d 1” dia 8, TPI, Jam Nut, qty 500
12.e 1 1\2”, 6 TPI. 7” long, with Castle Nut Cotter Pin, qty 100
Overview
Award Overview
Possible prior contracts
Sign in to see possible prior contracts for this requirement (matched by agency, NAICS and place of performance; not confirmed).
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
Lifecycle
- 1Version 1Presolicitation
Steel and Other Metal Materials for the Marietta Repair Station: Stamford De-Watering Box Material PH 1
- 2Version 2Presolicitation
Steel and Other Metal Materials for the Marietta Repair Station: Stamford De-Watering Box Material PH 1
- 3Version 3Presolicitation
Steel and Other Metal Materials for the Marietta Repair Station: Stamford De-Watering Box Material PH 1
- 4Version 4PresolicitationCurrent
Steel and Other Metal Materials for the Marietta Repair Station: Stamford De-Watering Box Material PH 1
Similar Opportunities
Title | Phase | Agency | NAICS | Set Aside | Posted | Deadline | Location |
|---|---|---|---|---|---|---|---|
Additional Details
Solicitation Number
W9123727QA011
Archive Date
Nov 12, 2026
Office Address
HUNTINGTON, WV, 25701-5000