GovChime
Notice ID: e7d21cc981254ddba70cefd2e5da6072Sources Sought

6515--Digital Non-Mydriatic Retinal Camera

Active, responses due . Full description on SAM.gov.

Overview

Response deadline
9:00 AM EST
Posted
November 5, 2026
Notice type
Sources Sought
NAICS
339112: Surgical and Medical Instrument Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Place of performance
East Indianapolis VA Clinic, Indianapolis, Indiana, 46229
PSC
6515: MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
Last updated
Nov 5, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25027Q0097
Notice ID
e7d21cc981254ddba70cefd2e5da6072

Description

Digital Non-Mydriatic Fundus Camera System This announcement requests information from industry to support market research and preliminary acquisition planning for the procurement of (1) one digital non-mydriatic fundus camera system with retinal image-capture software and vendor installation for the new East Indianapolis VA Clinic Tele-Eye Screening room. Of particular interest is identifying products that are made in America and meet the domestic end-product test of FAR 25.101. This is not a solicitation for proposals. No contract will be awarded from this notice. REQUIREMENT The agency is seeking information on sources of supply for one digital non-mydriatic fundus camera system with retinal image-capture software. Description: Compact, non-mydriatic digital retinal imaging system designed to acquire high-resolution color and fundus autofluorescence images of the human retina. The system shall support screening, documentation, and monitoring of ocular conditions without routinely requiring pharmacological pupil dilation. Salient Characteristics: Shall provide color retinal photography and fundus autofluorescence imaging. Shall produce retinal images with a resolution of at least 32 megapixels. Shall use infrared light for patient alignment and focusing before image capture. Shall acquire images through pupils approximately 3.3 mm in diameter or smaller without routinely requiring dilation. Shall provide automated alignment, focusing, exposure adjustment, image capture, and switching between anterior-eye and retinal observation. Shall permit the operator to override automatic focusing and manually adjust focus when necessary. Shall automatically evaluate image focus and eye alignment and alert the operator when image quality is insufficient. Shall provide digital image-processing modes capable of emphasizing retinal vascular and structural features, including red-free and blue-spectrum viewing modes. Shall include contrast-enhancement processing to improve differentiation between retinal blood vessels and surrounding tissue. Shall use low-intensity flash illumination to minimize pupil constriction and support sequential image acquisition. Shall provide adjustable image-sensitivity settings covering a range equivalent to ISO 200 through ISO 6400. Shall include an integrated display that allows the operator to preview and verify captured images at the imaging device. Shall include a complete retinal image-capture and management software package supporting image acquisition, patient-data entry or import, image review, processing, storage, and export of retinal images and associated patient information in DICOM and commonly used image formats. The software shall support DICOM worklist and electronic medical record integration when properly configured. Minimum of one-year manufacturer warranty coverage. Interested parties who can provide a product that meets the description above are requested to submit the following information: Product information documenting salient characteristics, Company name, address and point of contact with phone number, SAM Unique Entity Identifier (UEI), Place of manufacture, Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc., Any other pertinent company documentation. Note: All interested parties must be registered in SAM (System for Award Management) to be eligible for the award of a future Government contract. Send submissions to Brian.Rosciszewski@VA.gov., reference 36C25027Q0097 in email subject. This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. Respondents may not be notified of the results of this notice; it is at the discretion of the Government to release any results. Thanks in advance for your time and consideration in supporting America s veterans. ** End of Sources Sought Notice **

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Brian Rosciszewski
Contracting Officer

Documents

Files (1)

  • 36C25027Q0097.docx

    26 KBAdded in Sources Sought version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Sources SoughtCurrent

    6515--Digital Non-Mydriatic Retinal Camera

    Notice e7d21cc981254ddba70cefd2e5da6072 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

36C25027Q0097

Archive Date

Nov 23, 2026

Office Address

DAYTON, OH, 45428