GovChime
Notice ID: eb6a5c5b537a4bf1a7a6505f386c7da6Sources Sought

Z--YOSE 22866 Rehabilitate Hodgdon Meadows Water System and YOSE 196755 Extend Hod

Responses closed . Full description on SAM.gov.

Overview

Response deadline
11:00 AM MST
Posted
October 19, 2026
Notice type
Sources Sought
NAICS
237110: Water and Sewer Line and Related Structures Construction
Agency
Department of the InteriorDEPARTMENTAL OFFICES

Notice details

Office
NATIONAL PARK SERVICE CONTRACTING ACTIVITY
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
140PP027R0009
Notice ID
eb6a5c5b537a4bf1a7a6505f386c7da6

Description

YOSE 22866 Rehabilitate Hodgdon Meadows Water System and YOSE 196755 Extend Hodgdon Meadow Campground Sewer

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Files (1)

  • A14_SSN_140PP027R0009__YOSE_22866_1.pdf

    318 KBAdded in Sources Sought version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Sources SoughtCurrent

    Z--YOSE 22866 Rehabilitate Hodgdon Meadows Water System and YOSE 196755 Extend Hod

    Notice eb6a5c5b537a4bf1a7a6505f386c7da6 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
GRTE 237343 - "Rehabilitate 4 Lazy F Ranch Cabins for Employee Housing" UPDATE: See AM 003 for NPS responses to RFI's received. This solicitation is being issued as a Total Small Business Set Aside. Please see the attached solicitation package for details regarding this construction project at Grand Teton National Park. Please contact only the Contracting Officer at anthony_jasper@ios.doi.gov if you have questions pertaining to this project. Thank you for your interest in working with the National Park Service.
-Solicitation11/20/2026
GRCA 318719 North Rim & Roaring Springs Rehabilitation Program
-Solicitation01/08/2027
NGWSP Turnout Buildings
-Solicitation12/01/2026
Amendment 3. HAVO 326181 Rehabilitate Rainshed & Water Treatment System located at Hawaii Volcanoes National Park, Volcano, Hawaii
-Solicitation11/20/2026
This announcement is to all Small Business, 8(a) Small Business, HUBZone Small Business, Indian Small Business Economic Enterprises, Service-Disabled Veteran-Owned Small Business and Women-Owned Small Business concerns that may be interested in performing a contract for the California Great Basin Region of the Bureau of Reclamation. The work to be performed is described below. Based upon response to this announcement, the Government may determine to set this acquisition aside or proceed with an unrestricted solicitation. The applicable North American Industry Classification System (NAICS) Code is 237110 and the related small business size standard is $45M. This notice is not a request for proposal and the information presented in this announcement will not obligate the Bureau of Reclamation in any manner. The estimated cost of this project is $500,000.00-$1,000,000.00. This procurement will require 100% performance and payment bonds. This sources sought notice is for market research and acquisition planning purposes only. No formal solicitation for this work exists at this time. The work is located at the Oak Shores and Smittle Recreation Areas located in Napa County, California. Interested parties should include the following information in their response: (a) Business name, address, cage code, size classification based on NAICS size standard, socioeconomic classification (i.e. HUBZone; 8(a), etc.), and a point of contact; (b) A positive statement of your intention to submit an offer for this solicitation as a prime contractor; (c) Evidence of your experience performing work similar in type and scope to the work in this announcement within the last five years. The evidence should include: contract numbers, project titles, dollar amounts and points of contacts with telephone numbers. Please do not include more than three past projects; and (d) Include attachments cataloging the company's equipment assets, personnel resources and financial resources that demonstrate company responsibility and capability to perform required work. (e) If bonding is required, also provide evidence of your bonding capacity; All interested parties are encouraged to respond to this notice, by e-mail to Marianna_mezentseva@ios.doi.gov not later than 5PM PDT on November 11, 2026. The information provided in this announcement is all information the Government has available at this time. There are no specifications, drawings, bid packages, or source lists available. System for Award Management (SAM) applies to this procurement. Prospective contractors must be registered in the System for Award Management (SAM) prior to award. Lack of registration in the SAM database will make an offeror ineligible for award. Information on SAM registration can be obtained via the Internet at http://www.sam.gov PRINCIPAL COMPONENTS OF WORK: ¿ Replace 2¿ gate lateral valve at Main rated for 200 psi. ¿ Install N30 utility valve box w/water on lid, and appropriate quantity of risers to surface grade at Main lateral shut off 2¿ valve ¿ Reduce to 1¿ for lateral pipe to C.S. Install 1¿ lateral water line from main line 2¿ valve to PRV and 1¿ gate valve at rear of C.S. at Chase room ¿ Install 1¿ pressure reducing valve and 1¿ gate valve at rear of C.S. at Chase room Exterior in the proximity ¿ Install 1¿ pressure reducing valve and 1¿ gate valve rated for 200 psi. ¿ Install N30 utility valve box w/water on lid, and appropriate quantity of risers to surface grade over 1¿ PRV and gate valve ¿ Drill holes in brick on each side of C.S. Chase room access door approx. 1 ft above exterior floor ¿ Install 1¿ galvanized pipe from exterior PRV/gate valve, split into 2 lines, and run pipe in each hole to near interior copper line connection point. Fill wall holes with concrete. ¿ Install interior PRV and 1¿ gate valve, and tee with pressure gauge (1¿ face 0 to 60 psi) after PRV between 1¿ galvanized pipe and copper pipe, connect to copper pipe on each side of Chase room ¿ Flush and pressure test all connections prior to backfill of excavation from main lie to copper line connections interior of Chase room
-Market Research11/11/2026

Additional Details

Solicitation Number

140PP027R0009

Archive Date

Feb 25, 2027

Office Address

Denver, CO, 80225