Notice ID: ebcbaa01f89a4393a9960a84633dc21bSources Sought
Y1PZ--578-19-026: Installation of Hines Gate Control at the Hines VA Hospital in Hines, IL
Responses closed . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 PM CDT
- Posted
- September 28, 2026
- Notice type
- Sources Sought
- NAICS
- 238210: Electrical Contractors and Other Wiring Installation Contractors
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 252-NETWORK CONTRACT OFFICE 12 (36C252)
- Place of performance
- 5000 South 5th Ave, 60141-5000
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C25227B0004
- Notice ID
- ebcbaa01f89a4393a9960a84633dc21b
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY Solicitation: 36C25227B0004 Project: 578-19-026 Hines Gate Control System Place of Performance: Edward Hines, Jr. VA Hospital (EHVAH) 5000 South 5th Avenue Hines, IL 60141-5000 PART 1 - General Description: The purpose of this notice is to obtain information on the interests, capabilities, and qualifications of multiple types of small business firms to determine if a set-aside is appropriate. Responses to this Sources Sought announcement will be used by the Government to make appropriate acquisition decisions. Proposals are NOT being requested or accepted at this time. The Department of Veterans Affairs, Great Lakes Acquisition Center, requests a letter of interest from the following types of specialized construction small businesses firms interested in performing construction work at the Edward Hines, Jr. VA Hospital: Service-Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), Women Owned Small Businesses (WOSB), 8(a) Businesses, HUBZone Businesses, and Small Businesses (SB) Large Business This project is classified under NAICS Code: 238210 - Electrical Contractors and Other Wiring Installation Contractors with a small-business size limit of $19.0 Million and PSC Y1PZ (Product Service Code Construction Other Non-Building Facilities) In accordance with VAAR 852.219-75(a)(iii) Special trade construction contractors, should this acquisition be procured as an SDVOSB or VOSB - [ ] The contractor will not pay more than 75% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 75% subcontract amount that cannot be exceeded. Costs of materials are excluded and not considered to be subcontracted. https://www.va.gov/oal/library/vaar/vaar852.asp#85221975 The magnitude of construction for this work is more than $10,000,000. The period of performance shall not exceed 450 calendar days. PART 2 - SCOPE OF WORK OVERVIEW: The existing gate system and perimeter fencing at the Hines VA campus does not have video surveillance, card reader access, pedestrian access gates, remote gate control and in some locations damaged fencing or missing sections. Most of the existing gates need to be closed manually and do not have mechanical drives for closure. The primary objectives of this contract are to furnish all labor, materials, equipment, tools, and qualified supervision necessary to: 1) Task 1: Install upgraded and code compliant power and communications infrastructure to support security systems and gate operations for Building 205 and Gates 2, 3, and 4 and replace any non-compliant perimeter fencing along 5th Avenue. 2) Task 2: Modernize and secure campus primary entrance (Gate 1), by implementing power, communications, security, fence, and gate control improvements at Gate 1 in the northeast sector and replace any non-compliant perimeter fencing surrounding Gate 1. 3) Task 3: Remove and permanently close Gate 13 and replace all non-compliant perimeter fencing along the Roosevelt Road fence line 4) Task 4, enhance northwest perimeter security by upgrading Gates 11 and 12, integrating required systems, and replacing non-compliant fencing along southbound 9th Avenue to Gate 10. 5) Task 5, strengthen the west perimeter by improving fencing and modernizing Gate 10 to support controlled access, and replace non-compliant fencing from Gate 10 to the southern boundary. 6) Task 6, upgrade Gate 7 to improve access control and security along the central southeastern perimeter and replace non-compliant fencing to the north and east of Gate 7. 7) Task 7, improve perimeter security near Building 37 by upgrading Gate 14 and associated communications infrastructure, and replace non-compliant fencing to the north and east of the building. 8) Task 8, enhance the southeastern perimeter by renovating Gates 8 and 9 and integrating required electrical, communications, and security upgrades, and replace non-compliant fencing along 1st Avenue. 9) Task 9, reconstruct the southern perimeter fence line to meet VA security standards and replace all non-compliant fencing. PART 3 - Interested sources shall submit the following: Company name, address, point of contact, phone number, SAM OID number, and business status. Indicate the primary nature of your business, any teaming agreements or arrangements, self- performance, and intentions of subcontracting program, including set-asides. Documentation relating to capability of performance. Provide two (2) examples of projects similar in scope, complexity, and cost magnitude of project description above. Letter from the surety regarding the maximum bonding capability for a single contract action as well as the total aggregate bonding capacity. Total submittal shall be no longer than (6) six pages in one .pdf file or word document. Responses are required to be sent via email to Kristi.Kluck3@va.gov no later than Monday, October 5, 2026, CST. THIS IS NOT A REQUEST FOR PROPOSALS. It is a market research tool being utilized to determine the availability of potential qualified contractors before determining the method of acquisition. In addition, this Sources Sought is not to be construed as a commitment by the government, nor will the government pay for any information solicited or delivered.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C25227B0004.docx
29 KBAdded in Sources Sought version 1Posted
Lifecycle
- 1Version 1Sources SoughtCurrent
Y1PZ--578-19-026: Installation of Hines Gate Control at the Hines VA Hospital in Hines, IL
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Amendment A0004 This Amendment 0004 extends out due date. We are working on responses to a few additional RFIs and will publish the responses in Amendment A0005. VIRTUAL BID OPENING INFORMATION: 1) There will be no in-person public bid opening process. This will be conducted as a public virtual activity. 2) The virtual bid opening will be available to the public via Microsoft Teams at the following link and/or phone number: Join: https://teams.microsoft.com/meet/2473414420095?p=HOJS7WNgrbgMwvO73f (Meeting will be available to be accessed 10 min prior to bid opening) Meeting ID: 247 341 442 009 5 Passcode: ks79ub9w Dial-in by phone: 1-872-701-0185; Phone conference ID: 947 858 19# 3) IAW FAR 52.214-5 Submission of Bids and FAR 14.202-8 Electronic Bids; Bids shall be provided via email to the Contracting Officer at Lynn.VanderVelde@va.gov AND Ryan.McMillin@va.gov as follows: with Subject: 36C25226B0014 BIDS DUE: Vendor bids are due via email as shown above at 10:00 AM local time on December 1st. The virtual public bid opening will be held at 11:30 AM local time on December 1st at the link and/or the phone # provided above. ……..End of Amendment A0004…….. | - | Solicitation | 12/01/2026 |
The Department of Veterans Affairs is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in, and the resources to support replacement of automatic transfers switches at multiple buildings located at Captain James A. Lovell FHCC, North Chicago, IL 60064. The result of this market research will contribute to determining the method of procurement and potential interest. The anticipated North American Industry Classification System (NAICS) code for this procurement is 238210 – Electrical Contractors and Other Wiring Installation. It is also anticipated this will be set-aside 100% Service Disabled Veteran Owned Small Bussiness, unless research indicates otherwise. | - | Market Research | 11/09/2026 |
| - | Awarded | Open | |
| - | Awarded | Open | |
CONSTRUCTION STATEMENT OF WORK Date: September 13, 2025 Project Number: 556-24-113 Project Name: Oil Transformer and Switch Enclosure Upgrade (GC) Location: Captain James A. Lovell FHCC 3001 Green Bay Rd, North Chicago, IL 60064 Part 1: Project Scope of Work Overview: Contractor shall provide all tools, materials, labor, quality assurance, and supervision for renovations resulting in a complete, compliant, and fully-functional project. Replace medium voltage oil-filled transformers that serve the following buildings on the James A. Lovell FHCC campus: 1, 3, 9, 11, 66, 137 and 187. Transformers have 4160 volt primary and 208/120 volt secondary. There are (4) transformers rated for 150 KVA, (2) transformers rated for 300 KVA and (1) transformer rated for 750 KVA. The 150 KVA transformer at building 3 will need to be relocated as well. Replace the electrical distribution switchboard at building 137. Replace the electrical distribution switchboard at building 3. Replace concrete pads for medium voltage oil filled transformers at buildings 9, 66, and 187. New transformer location at building 3 requires a new concrete pad as well. Install anti-ram rated bollards at all transformers. Part 2: Period of Performance: The following model presents the summary logic of the milestone sequence working backward from the delivery date of the longest lead time in the critical path to determine a mobilization date, and then forward from the delivery date of the longest lead time to completion of all work. Listed milestones and phases (calendar days): Notice To Proceed Day 0 Division 01 Submissions Completed Day 14 Division 01 VA Reviews Day 35 Division 02+ Submissions Day 50 Division 02+ VA Reviews Day 71 Longest Lead Item Procurement Day 72 (GC to determine and submit) VA review and GC revise schedule Day 93 Mobilize and Demo Day 94 (If all pre-construction submittals were approved) Pre-Longest Lead Item Construction Day 214 (GC to determine) Longest Lead Item Delivery Date Day 215 (GC to determine) Post Long-Lead Item Construction Day 335 (GC to determine) Construction Complete and Closeouts approved Day 356 Closeout (Contract end date) Day 357 Total: 357 days reflects an example workup of the plan. GC must submit the factory ship date commitment to VA and revise the Baseline Schedule to work forward and backward from that date to optimize the time in field (disruption of customer and reduction of GC costs). Part 3: Detailed Project Requirements: Project Objectives: Contractor is required to expedite planning and execution of this work, enabling the work to start and continue without interruptions caused by failure to procure long lead equipment and plan around the delivery dates This project is required to enable compliant and safe conditions for maintenance of electrical systems. GC and their consulting engineer to plan and execute a robust quality assurance plan and safety plan to prevent time and rework losses. List of AE Documents to be included in this Contract: See: 00 01 10 Table of Contents and the entire Project Manual See: 00 01 15 List of Drawing Sheets and the entire volume of drawings Pre-Bid Conference: VA shall schedule one pre-bid conference to be attended by prospective bidders to observe current conditions within the work area(s). Do not expect additional events to occur. The AE shall not attend the pre-bid event. No questions will be allowed during the event. All questions by all prospective contractors shall follow the RFI process described in the Solicitation. Prospective bidders shall not attempt to contact the AE or VA facilities engineering staff during the solicitation and bidding period. The AE and VA facilities engineering staff are instructed to ignore all such inquiries and report them to the VA Contracting Officer. All inquiries regarding this project shall be presented as complete and coherent Requests for Information (RFI) specifically citing design or specification sections, pages, paragraphs, notes, details, etc. to enable responses to RFI s. Follow the instructions provided by the Contracting Officer within the Solicitation regarding submission of RFI s. VA will post responses developed to enable all prospective bidders to receive the same information at the same time. | - | Solicitation | 09/09/2026 |