GovChime
Notice ID: f1187ff4bdbe49fb99b2ca31bf1556b5Combined Synopsis/Solicitation

wavelength meter

Responses closed . Full description on SAM.gov.

Overview

Response deadline
12:50 PM EDT
Posted
April 2, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
334516: Analytical Laboratory Instrument Manufacturing
Agency
Department of WarDepartment of the Army

Notice details

Office
AMC.ACC.MISSION INSTALLATION CONTRACTING COMMAND.419TH CSB.W6QM MICC-FT DRUM
Place of performance
Photonics Research CenterBartlett Hall Science Center, 753 Cullum Rd, Rm 191, West Point, New York , 10996
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W911S226U2952
Notice ID
f1187ff4bdbe49fb99b2ca31bf1556b5

Description

High-precision wavelength meterWavelength measurement range 330 -1180 nanometers. Accuracyof plus/ minus 900 MHz for wavelengths between 330 -375 nm. Accuracy of plus/ minus600 MHz for wavelengths between 375 -800 nm. Accuracy of plus/ minus 500 MHz forwavelengths between 800 -1180 nm. Must support both continuous-wave and pulsedsources. Minimum measurement speed of 950 Hz. Internal calibration included.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationCurrent

    wavelength meter

    Notice f1187ff4bdbe49fb99b2ca31bf1556b5 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Tunable wavelength range from 1480 to 1640 nanometers.Continuous-wave, mode-hop-free operation across the entire tuning range.Laser linewidth less than 200 kHz.Wavelength setting resolution of 0.1 picometers or better.Wavelength accuracy of 15 picometers or better in step mode and continuous sweep operation.Wavelength stability of 5 picometers or better over typical operating conditions.Minimum output power of 7 dBm across the tuning range.Fast wavelength sweep capability from 1 to 200 nm/s with programmable control. Fine tuning capability over at least 10 GHz. Fiber-coupled output compatible with standard single-mode fiber systems with polarizing maintaining fiber output coupling.Remote control via USB, GPIB, and Ethernet interfaces.
-Combined Synopsis06/12/2026
Rugged Spectrometers
-Combined Synopsis11/17/2026
MINICAMS PARTS / Submission Requirements and Technical Compliance - Submission Method: Only bids submitted through the official solicitation portal will be accepted. Emailed submissions will not be considered.Brand Name or Equal: This solicitation is brand name or equal. If quoting an equal product, the bidder must demonstrate that the product meets or exceeds all salient physical, functional, or performance characteristics listed in the description.Mandatory Documentation: A completed Buy American form is required. Bids submitted without a completed form may be deemed non-responsive and rejected.Shipping and Invoicing: Prices must include all shipping, packaging, and inspection charges. A single shipment and invoice are required. Multiple shipments require prior written approval from the WDTC S2P2 Point of Contact (POC).
-Combined Synopsis11/16/2026
Solicitation Amendment for Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES)
-Combined Synopsis11/15/2026
Nitrogen Content Analysis Equipment: Amendment 0001: 1. Which nitrogen analysis instrument does the laboratory operate today? - Nitrogen determination divides into Kjeldahl and Dumas combustion methods, and the two are not interchangeable with an existing accredited method.The nitrogen analysis is performed using a ferrous sulphate potentiometric titration method. The needed equipment was specified in the solicitation.2. Which method is required here, and is there a required make and model, or will an equal meeting stated salient characteristics be considered? If salient characteristics have been documented, please confirm where they are posted.- Method 4.5.1.2 of MIL-N-00494B and 4.5.1 of MIL-DTL-244C Amendment 1; both publicly available documents. 3. Sample matrix and required throughput.N/A see method4. Scope: is an autosampler, digestion unit, scrubber or fume handling included? Are consumables and reference standards included?No5. Are installation, operational qualification and operator training within contractor scope?This was detailed in the solicitation. 6. Required warranty term and whether a service or calibration plan is in scope.This was detailed in the solicitation. 7. Required delivery date.This was detailed in the solicitation. Amendment 0002: added Brand Name Solicitation
-Combined Synopsis10/29/2026

Additional Details

Solicitation Number

W911S226U2952

Archive Date

Apr 2, 2027

Office Address

FORT DRUM, NY, 13602-5220