GovChime
Notice ID: e6ecff0a97e649b9b8030edaf5ace57aPresolicitationArchived

Three-phase oil transformer in hermetic design

Archived on March 8, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
11:00 AM GMT+1
Posted
February 6, 2026
Notice type
Presolicitation
Set-aside
No Set aside used
NAICS
335311: Power, Distribution, and Specialty Transformer Manufacturing
Agency
Department of WarDepartment of the Air Force

Notice details

Office
U.S.AIR FORCES IN EUROPE.FA5606 52 CONS DA LGC
Place of performance
Spangdahlem, Rhineland-Palatinate, 54529
PSC
6150: MISCELLANEOUS ELECTRIC POWER AND DISTRIBUTION EQUIPMENT
Last updated
Nov 4, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
F3W3426029A001
Notice ID
e6ecff0a97e649b9b8030edaf5ace57a

Description

1 each three-phase oil transformer in hermetic design according to DIN EN 50588 Loss series AAo/AK with reduced power losses in accordance with the European Commission's Ecodesign Regulation, with zere tolerance, stage 2 from July 1, 2021, with the following specs: High voltage (HV) 20,000 V; Low voltage (LV) 400/230 V; Voltage Tapping 5 steps ± 2x2.5%; Vector Group Dyn5; Frequency 50 Hz; Cooling Method 3. Length approx. 1,340 mm; Width approx. 1,045 mm; Height approx. 1,630 mm; Weight approx. 2,650 kg; Oil weight approx. 490 kg.

Additional accessories:

1 each Transformer protection relay RIS/DMCR/DGPT2

3 each Euromold plug bushings for 250A angle plugs

4 each Transformer connection terminals, four wire, 35-240 mm², for M30x2 feed-through, for terminals 2DIRECT-CL/35-240/4x/L/M30x2 (Pfisterer 331 747 001); clamps for terminal bolts compliant with DIN EN 50386; DIN EN 50386 compliant bolted connections (1 kV). Type tested in compliance with IEC 61238 with Cu cables, 240 mm².

4 each Cover for 2DIREKT Four Wire Terminal, for Bolted Connections M30-M24, Indoor Use (Pfisterer 331 347 001).

4 each additional covers for Screw with Ball Pin.

4 each vibration dampers EK90

60 meters 20 kV cable type N2XSY 1 x 35/RM 16.

The intention is to award to the vendor who is deemed responsible, responsive, and represents the best value to the Government based on selection of the lowest total price that is deemed technically acceptable.

In accordance with FAR 12.201-1 (c) (2) Contracting Officer has chosen to solicit quotations directly from suppliers. When soliciting directly-

(i)  Post a presolicitation notice in the GPE according to subpart 5.1, unless an exception in 5.101(b) applies.

(ii)  Solicit quotations from at least three sources; and

(iii) Whenever practicable, solicit quotations from two sources not included in the previous solicitation.

In case you are interested in receiving the solicitation please feel free to contact the Primary or the Secondary Point of Contact.  

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

No documents available.

Lifecycle

  1. 3
    Version 3PresolicitationArchivedCurrent

    Three-phase oil transformer in hermetic design

    Notice e6ecff0a97e649b9b8030edaf5ace57a on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

F3W3426029A001

Archive Date

Mar 8, 2026

Place of Performance Country

GERMANY

Office Address

APO, AE, 09126-3910