RFI-Recommendation or Suggestion for a Replacement AC Unit
Archived on March 7, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 4:00 PM CST
- Posted
- February 12, 2026
- Notice type
- Presolicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 423730: Warm Air Heating and Air-Conditioning Equipment and Supplies Merchant Wholesalers
- Agency
- Department of WarDepartment of the Air Force
Notice details
- Office
- AIR EDUCATION AND TRAINING COMMAND.JOINT BASE SAN ANTONIO.FA3016 502 CONS CL
- Place of performance
- San Antonio, Texas
- Last updated
- Nov 3, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- FA3016FY2620TONAC
- Notice ID
- a4cfc7adb3be4e59843b8f8c8888d63d
Description
This message is a Request for Information issued for market research purposes. We are looking for any recomendations or suggestions for a comparable replacement for a 20 TON Split A/C unit.
The replacement needs to be compatible with the following specifications:
Outdoor Unit (Condenser):
Nominal Capacity: 20 TON (240,000 BTU/h)
Voltage: 208/230V – 3 Phase – 60HZ
Refrigerant TYPE: R-22
Compressors: 2-Stage (Dual) Scroll Compressors
Fans: 2
Efficiency: Up to 11.0 EER / 14.8 IEER
Dimensions: ~50.4” H x 103.4” W x 54.3” D
Weight: 1133lbs
Inside Unit (Air Handler):
Nominal Capacity: 20 TON (240,000 BTU/h)
Fan Motor Horsepower: 3HP
Nominal Air Flow: 8000 CFM
Electrical: 208/230 Volt, 3-Phrase, 60Hz
Cooling Coil: 4-Row Direct Expansion (DX) Coil (Copper Tube, Aluminum Fin)
Commercial Heat Element Kit
For Air Handler Unit: 20 TON
Voltage: 240Volts – 3 Phase – 60HZ
240 Volts, 3 Phrase
Heating Capacity 19.1W
Total Amps: 46 AMPS
The Statement Of Need and pictures of the current unit are attached for reference.
Please be advised this is an RFI only. This inquiry does not constitute a solicitation, a Request for Quote (RFQ), or a promise to issue and RFQ in the future. A contract will not be awarded based on responses to this notice.
We kindly request that you provide any recommendations no later than, Friday, February 20th by 16:00 CST.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
Files (5)
- Download
IMG_0226.jpeg
909 KBAdded in Presolicitation version 3Posted - Download
IMG_0225.jpeg
1.1 MBAdded in Presolicitation version 3Posted - Download
Name Plate AHU B41.jpg
85 KBAdded in Presolicitation version 3Posted - Download
Heating Element for AHU B41.jpg
91 KBAdded in Presolicitation version 3Posted - Download
Statement of NEED 20 TON Split AC System.docx
50 KBAdded in Presolicitation version 3Posted
Lifecycle
- 3Version 3PresolicitationArchivedCurrent
RFI-Recommendation or Suggestion for a Replacement AC Unit
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
FA3016FY2620TONAC
Archive Date
Mar 7, 2026
Office Address
JBSA LACKLAND, TX, 78236-5286