Eaton 9390 Battery System Modernization
Archived on May 10, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 4:30 PM CDT
- Posted
- April 8, 2026
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 811210: Electronic and Precision Equipment Repair and Maintenance
- Agency
- Department of WarDepartment of the Air Force
Notice details
- Office
- AIR EDUCATION AND TRAINING COMMAND.FA3020 82 CONS LGC
- Place of performance
- DWG, Texas, 76311
- PSC
- J059: MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS
- Last updated
- Oct 31, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- FA302026Q0032
- Notice ID
- 074f4f4467cc49bc912cc2dd1617c473
Description
The United States Air Force requires the replacement of end‑of‑life batteries and capacitors for the Eaton 9390 Uninterruptible Power Supply (UPS) located in Building 237 at Sheppard AFB, TX. This requirement falls under PSC J059, NAICS 811210, with a corresponding $34M size standard. The project will modernize the existing UPS by installing a new, optimized Eaton battery configuration that reduces the total number of batteries while maintaining the capability to support a 30 KVA critical load for a minimum of two hours. All aged capacitors within the Eaton 9390 unit will be replaced to restore the system to original factory specifications and prevent potential failure points. In accordance with the approved brand‑name justification, all components must be new Eaton hardware, and all work must be performed by an Eaton‑certified technician. The contractor will be responsible for conducting a mandatory site visit to verify field conditions and measurements, safely removing and disposing of all existing batteries in compliance with federal, state, and local environmental regulations, and performing full system testing to validate proper operation under simulated power‑loss conditions.
A mandatory site visit is scheduled for 15 April 2026 at 9:30 a.m. CST and the meeting location is at the Sheppard AFB Visitor Center, 210 Missile Rd, Wichita Falls, TX 76311. Vendors must email cristhian.gonzalez_tovar@us.af.mil and kimberly.rico@us.af.mil no later than 13 April 2026 (COB) to coordinate base access. Questions regarding this requirement may be submitted to the POC and Contracting Officer no later than 17 April 2026 at 1:00 p.m. CST, questions received after this deadline may not receive a response. Quotes must be submitted via email to the POC and Contracting Officer by 25 April 2026 at 4:30 p.m. CST and must remain valid for 90 days along with Statement of Work (SOW) describing the solution to modernize Eaton system. All pricing must be submitted using the provided COMBO; vendors may include a supplemental quote on a company letterhead, but all technical submissions must be provided in a separate document. Vendors must also complete the contractor identification section included in the solicitation COMBO.
Award Overview
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
Files (4)
- Download
RFO Combo - 82 CS UPS Battery System Modernization.pdf
2.7 MBAdded in Combined Synopsis/Solicitation version 3Posted - Download
Attachment 1 - Statement of Objective (SOO).pdf
114 KBAdded in Combined Synopsis/Solicitation version 3Posted - Download
Attachment 2 - Provisions and Clauses.pdf
19 KBAdded in Combined Synopsis/Solicitation version 3Posted - Download
Attachment 3 - Brand Name Justification.pdf
1.9 MBAdded in Combined Synopsis/Solicitation version 3Posted
Lifecycle
- 3Version 3Combined Synopsis/SolicitationArchivedCurrent
Eaton 9390 Battery System Modernization
Similar Opportunities
Additional Details
Solicitation Number
FA302026Q0032
Archive Date
May 10, 2026
Office Address
SHEPPARD AFB, TX, 76311-2743