GovChime
Notice ID: 024b786581ec4e85bec7dcfa3bbd6415SolicitationArchived

XTLF 25-1025 ELECTRICAL DISTRIBUTION RESILIENCE CIRCUIT 2 LOOP FEED

Archived on July 25, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
10:00 AM CDT
Posted
July 25, 2025
Notice type
Solicitation
Set-aside
Small Business Set Aside - Total
NAICS
238210: Electrical Contractors and Other Wiring Installation Contractors
Agency
Department of WarDepartment of the Air Force

Notice details

Office
FA3029 71 FTW CVC
Place of performance
Vance Air Force Base, Enid Oklahoma, Enid, 73705
Last updated
Nov 10, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
FA302925R0005
Notice ID
024b786581ec4e85bec7dcfa3bbd6415

Description

Project Title: XTLF 25-1025 ELECTRICAL DISTRIBUTION RESILIENCE CIRCUIT 2 LOOP FEED Project Location: Vance AFB, Enid Oklahoma Notice to Offeror(s) and Supplier(s): Funds are not presently available for this effort. No award will be made under this solicitation until funds are available. Once funds are available, bid guarantee will be required before award. The Government reserves the right to cancel this solicitation, either before or after the closing date for receipt of proposals. In the event the Government cancels this solicitation, the Government has no obligation to reimburse an offeror for any cost. The work includes the installation of one 15kV Class pad mounted distribution switch, two 15kV class pad mounted sectionalizing cabinets, the construction of approximately 1300 linear feet of duct bank and installation of approximately 1300 linear feet of 15kV class medium voltage cable. The electrical cable will connect to an existing pad mounted distribution switch and an existing pad mounted sectionalizing cabinet. This will project will require two horizontal directional drill installed sections of the duct bank, connection into an existing manhole, pulling electrical cable in 4 pull sections between medium voltage equipment, 24 dead break elbow terminations to connect the cable to the medium voltage equipment and incidental related work. This solicitation is a 100% Small Business Set-Aside.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Files (17)

  • Amendment FA302925R00050001 SF 30.pdf

    1.3 MBAdded in Solicitation version 7Posted
    Download
  • Attachment 5_Site Visit Sign-in Sheet.pdf

    193 KBAdded in Solicitation version 7Posted
    Download
  • Attachment 6_Question and Answers.pdf

    126 KBAdded in Solicitation version 7Posted
    Download
  • Solicitation - FA302925R0005.pdf

    1.6 MBAdded in Solicitation version 1Posted
    Download
  • Attachment 1_Specifications.pdf

    706 KBAdded in Solicitation version 1Posted
    Download
  • Attachment 2_Drawings.pdf

    4.0 MBAdded in Solicitation version 1Posted
    Download
  • Attachment 3_Vance AFB Map.pdf

    772 KBAdded in Solicitation version 1Posted
    Download
  • Attachment 4_Wage Determination OK20250038.pdf

    2.0 MBAdded in Solicitation version 1Posted
    Download
  • Attachment L1_Bid Form.pdf

    14 KBAdded in Solicitation version 1Posted
    Download
  • Attachment L2_Bond Checklist.pdf

    675 KBAdded in Solicitation version 1Posted
    Download
  • Attachment L3_Financial Responsibility Worksheet.pdf

    116 KBAdded in Solicitation version 1Posted
    Download
  • Attachment L4_Past Performance Information Form.pdf

    166 KBAdded in Solicitation version 1Posted
    Download
  • Attachment L5_Questionnaire Cover Letter.pdf

    99 KBAdded in Solicitation version 1Posted
    Download
  • Attachment L6_Past Performance Questionnaire.pdf

    321 KBAdded in Solicitation version 1Posted
    Download
  • Attachment L7_Consent Form.pdf

    132 KBAdded in Solicitation version 1Posted
    Download
  • Section L- Instruction Conditions and Notices to Offerors.pdf

    261 KBAdded in Solicitation version 1Posted
    Download
  • Section M - Evaluation Factors for Award.pdf

    147 KBAdded in Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1SolicitationArchived

    XTLF 25-1025 ELECTRICAL DISTRIBUTION RESILIENCE CIRCUIT 2 LOOP FEED

    Notice 91168abf3c9f4e35b3b03875eb482345 on SAM.gov

  2. 2
    Version 2SolicitationArchived

    XTLF 25-1025 ELECTRICAL DISTRIBUTION RESILIENCE CIRCUIT 2 LOOP FEED

    Notice 2ce62664b36943369d3c7313a296df52 on SAM.gov

  3. 7
    Version 7SolicitationArchivedCurrent

    XTLF 25-1025 ELECTRICAL DISTRIBUTION RESILIENCE CIRCUIT 2 LOOP FEED

    Notice 024b786581ec4e85bec7dcfa3bbd6415 on SAM.gov

  4. 6
    Version 6Award NoticeArchived

    Type changed from Solicitation to Award Notice

    XTLF 25-1025 ELECTRICAL DISTRIBUTION RESILIENCE CIRCUIT 2 LOOP FEED

    Notice 6ee2d06cae674fdf9e4a2245415c6402 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

FA302925R0005

Archive Date

Jul 25, 2026

Office Address

ENID, OK, 73705-5037