Notice ID: 5086bfe71b794d86a48078fb7693bd97Solicitation
Repair Facility 131
Archived on May 19, 2021. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 3:30 PM UTC−06:00
- Posted
- April 22, 2021
- Notice type
- Solicitation
- Set-aside
- Historically Underutilized Business (HUBZone) Set-Aside (FAR 19.13)
- NAICS
- 236220: Commercial and Institutional Building Construction
- Agency
- Department of WarDepartment of the Air Force
Notice details
- Office
- FA4877 355 CONS PK
- Place of performance
- Tucson, 85748
- Last updated
- Sep 25, 2026
Identifiers
- Solicitation number
- FA487721B0003
- Notice ID
- 5086bfe71b794d86a48078fb7693bd97
Description
Reconfigure and renovate existing restrooms, shower and janitor's closet including adding fixtures to the women restroom; consolidate/relocate Comm equipment to the existing server room; reconfigure facility entrance to accommodate a fire riser room for the new fore protection system; remove extraneous, unused or abandoned materials from exterior surfaces such as brackets, conduit, piping, wires, cables, insulators, anchors, inserts, and all similar items. Clean, prep and paint all exterior walls; provide new wet sprinkler protection for the entire facility including installation of a new fire water service line and Fire Department Connection (FDC); replace existing Fire alarm system with new analog/addressable all-in-one Monaco MAAP-X fire alarm and mass notification system; a complete new mechanical (HVAC) system including but is not limited to ductwork, piping, Direct Digital (DDC) controls, Variable Air Volume Systems (VAVs), chiller, pumps, Computer Room Air Conditioning (CRAC) units, exhaust fans, insulation and other accessories and miscellaneous items required for a complete operating system; this includes new CRAC unit(s) for server room; new electrical service feed for the facility including new primary service cabling, fuses (pole), transformers and service entrance conductors; a complete interior electrical system including service entrance equipment, panel boards and feeders, branch circuits, receptacles and outlets, grounding, and surge protection; includes repairs as required to correct life safety code deficiencies identified in Fire Protection Design Analysis and Life Safety Plans; corrects American with Disabilities Act (ABA)/Architectural Barriers Act (ABA) deficiencies; includes all repairs necessary to bring facility up to current security standards.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
No documents available.
Lifecycle
Solicitation:
FA487721B0003- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- 5×SolicitationCurrentMar 23, 2021
Repair Facility 131
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
FA487721B0003
Archive Date
May 19, 2021
Office Address
DAVIS MONTHAN AFB, AZ, 85707-3522