GovChime
Notice ID: ead8d821fd64480cb6582af93c3487b6Combined Synopsis/Solicitation

Boiler/Water Heater Maintenance

Archived on August 13, 2024. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
2:00 PM UTC−08:00
Posted
August 5, 2024
Notice type
Combined Synopsis/Solicitation
Set-aside
Small Business Set Aside - Total
NAICS
811310: Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Agency
Department of WarDepartment of the Air Force

Notice details

Office
FA5000 673 CONS PKB
Place of performance
99506
Last updated
Sep 25, 2026

Identifiers

Solicitation number
FA500024Q0014
Notice ID
ead8d821fd64480cb6582af93c3487b6

Description

Amendment 0002 - A document containing answers to questions received has been added to the attachments. No other changes have been made to the combined synopsis/solicitation or attachments. --- Amendment 0001 - Attachment 4, the Past Performance Questionnaire, stated an incorrect date on the page 1 cover letter. This date has been corrected to match the solicitation deadline of 12 August 2024 at 2:00 PM local Alaska time. No other changes have been made to the combined synopsis/solicitation or attachments. --- This is a combined synopsis/solicitation for commercial items prepared in accordance with (IAW) the format in Federal Acquisition Regulation (FAR) Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; offers are being requested and a written solicitation will not be issued. Solicitation is a Request for Offers under solicitation number FA500024Q0014 and is issued IAW FAR 13.106 and 13.5. The offer received in response to this solicitation, if accepted, will result in a binding contract. The 773 Civil Engineering Squadron (CES) requires boiler maintenance on Joint Base Elmendorf-Richardson - Elmendorf (JBER-E), Alaska. The contractor shall provide all items and non-personal services to include but not limited to management, personnel (IAW DFARS 252.222-7000, Restrictions on Employment of Personnel), transportation, equipment, and supplies required to provide for maintenance of boilers and associated systems on JBER-E. The contractor is responsible for maintaining management control systems necessary to plan, organize and direct all activities necessary to fulfill this requirement. Encompassing preventative and corrective maintenance, the requirement is for service of approximately 153 steam boilers ranging from less than 500 to greater than 1000 MBh, 48 Hydronic Boilers, 2 Furnaces, 36 Steam Hot Water heaters, 89 Back Flow Preventers and 28 Gas Unit Heaters.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

No documents available.

Lifecycle

Solicitation:FA500024Q0014
  1. Combined Synopsis
  1. 3×
    Combined SynopsisCurrentJul 10, 2024

    Boiler/Water Heater Maintenance

    Notice ead8d821fd64480cb6582af93c3487b6 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Notice of Intent to Sole Source to Phillips Corporation for updating software and preventative maintenance on a Haas UMC-750SS. GENERAL INFORMATION: Notice Type: Special Notice Contracting Office: 673d Contracting Squadron, JBER, AK Title: Notice of Intent to Sole Source to Phillips Corporation Response Deadline: 2:00PM AKST (6:00PM EST) on 17 Nov 2026 NAICS: 811310 PSC: J036 DESCRIPTION: The 673d Contracting Squadron on Joint Base Elmendorf-Richardson, AK has concluded their market research and intends to solicit, negotiate, and award a sole source firm-fixed price (FFP) contract under RFO 12, Acquisition of Commercial Products and Commercial Services, statutory authority of 10 U.S.C. 3204(a)(1), as implemented by RFO 6.103-1, Only one (1) responsible source and no other supplies or services will satisfy agency requirements to Phillips corporation, CAGE 3MPQ0. The proposed North American Industry Classification System (NAICS) code for this acquisition is 811310, with a small business size standard of $12.5 Million. REQUIREMENT DESCRIPTION: This FFP contract is for a non-personal service to provide technical and human machine interaction programming and preventative maintenance to the Metals Technology Maintenance Squadron shop’s 5th axis vertical milling machine. This service is required to restore the complete functionality of the Haas UMC-750SS that is used in the manufacturing and repairing of non-procurable aircraft and support equipment parts (See Attachment 1 - Haas UMC-750SS Statement of Work_Redacted). REASON FOR SOLE SOURCE: Based on concluded Market Research only Phillips Corporation can fulfill the entire requirement, to include software/firmware updates. SUBMISSION DETAILS: The anticipated award date is 18 November 2026. This notice is not a request for competitive proposals or quotes. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. A determination by the Government not to compete this proposed contract action based upon responses to this notice is solely within the discretion of the Government. Responses must be received no later than 17 November at 2:00 PM (6:00PM EST) AKST. Responses must be submitted via email to the POCs indicated below.. POINTS OF CONTACT (POC): Contract Specialist: Mr. Jarod Lemke, jarod.lemke.1@us.af.mil Contracting Officer: Mr. Joseph Ford, joseph.ford.21@us.af.mil
-Special Notice11/17/2026
SOURCES SOUGHT NOTICE Title: Central Heat and Power Plant (CHPP) Boiler Maintenance and Repair Services Department / Agency: Department of the Air Force Sub-tier: Pacific Air Forces (PACAF) Major Command: 354th Fighter Wing Office: 354 CONS / PK, Eielson AFB, AK 99702 1. GENERAL INFORMATION Contract Opportunity Type: Sources Sought Original Published Date: 10/7/2026 Original Response Date: 10/23/2026 at 16:00 AKST Applicable NAICS Code: Primary: 811310 – Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance (Small Business Size Standard: $12.5M) Secondary / Alternate: 238220 – Plumbing, Heating, and Air-Conditioning Contractors (Small Business Size Standard: $19.0M) Product Service Code (PSC): J044 – Maintenance, Repair, and Rebuilding of Equipment: Furnace, Steam Plant, and Drying Equipment Place of Performance: Central Heat and Power Plant (CHPP), Bldg 6203 Eielson Air Force Base, AK 99702 United States 2. STATUTORY AUTHORITY & DISCLAIMER This is a SOURCES SOUGHT SYNOPSIS conducted pursuant to RFO Part 10 (Market Research). This notice is issued solely for informational and planning purposes; it does not constitute a Request for Proposal (RFP), Invitation for Bid (IFB), or Request for Quotation (RFQ). This notice does not commit the U.S. Government (USG) to contract for any supply or service. The Government will not award a contract based on this Sources Sought, nor will it reimburse respondents for any costs incurred in preparing or submitting responses. Participation is strictly voluntary. Failure to respond to this announcement will not preclude an interested party from submitting an offer under any subsequent formal solicitation, should one be issued. Information received will be used within the Department of the Air Force to determine market capabilities, potential small-business set-aside opportunities, and procurement strategy. 3. DESCRIPTION OF REQUIREMENT The 354th Contracting Squadron (354 CONS) at Eielson AFB, Alaska, is conducting market research to identify qualified, capable, and certified commercial contractors interested in providing on-call, critical emergency and scheduled maintenance and repair services for the Central Heat and Power Plant (CHPP) high-pressure power boilers. A copy of the draft Performance Work Statement (PWS) is attached to this SAM.gov posting as Attachment 1. Vendors are strongly advised to review Attachment 1 in its entirety prior to responding. 3.1 Background & Plant Criticality The Eielson AFB CHPP provides vital thermal heat and electrical power to all base facilities under extreme sub-arctic winter conditions (temperatures regularly dropping below -40°F). Unplanned boiler outages pose immediate life-safety, mission, and infrastructure failure risks. Consequently, repair response times and quality standards are non-negotiable. 3.2 Equipment Inventory The requirement encompasses six (6) utility-grade, coal-fired high-pressure power boilers and their associated support systems: Four (4) Springfield Boiler Co. Model #1951 coal-fired high-pressure boilers. Two (2) Indeck Keystone Energy Model #2013 coal-fired high-pressure boilers. 3.3 Core Performance Scope (Refer to PWS Sections 1.0 – 2.5) The contractor shall provide all management, personnel, labor, transportation, tooling, equipment, and certified materials to perform: 24-Hour Emergency Physical On-Site Response: A qualified technician must be physically present on-site at Eielson AFB within 24 hours of initial call-out notification from the Contracting Officer (CO) or Contracting Officer’s Representative (COR). On-Site Inspection & Letter of Recommended Repair (LRR): Submission of a detailed LRR (including root cause, part numbers, compliance citations, labor hours, lead times, and a firm-fixed-price proposal) within one (1) business day of inspection. CO Notice-to-Proceed (NTP) Enforcement: No parts ordering or work beyond initial inspection may occur without formal written authorization from the Contracting Officer. Full Boiler Envelope & Pressure Vessel Repair: Extensive repairs to include any and all associated piping related to boiler production but not limited to: welding, rolling, reshaping, and replacement of water wall tubes, superheater tubes, economizer tubes, generating tubes, pier tubes, front/sidewall/rear headers, superheater headers, mud drums, steam drums, power piping, blowdown drains, safety valves, hand holes, manholes, soot blowers, baffles, and gas passes. No Government-Furnished Property (GFE/GFP): The Government will furnish zero tools, vehicles, facilities, tube rollers, or welding equipment (PWS Section 4.4). Base Security & HAZMAT: Personnel must be vetted via the Defense Biometric Identification System (DBIDS) and satisfy Bioenvironmental Engineering SDS/HAZMAT approval processes prior to bringing materials on-site. 4. MANDATORY QUALIFICATION THRESHOLDS To be deemed capable under this requirement, respondents must demonstrate compliance with the following mandatory qualifications (see PWS Section 3.0): ASME "R" Stamp: The prime contractor must hold an active National Board "R" (Repairs and Alterations) Stamp Certificate of Authorization. ASME Section IX Welder Certifications: All personnel executing welding and repair tasks must hold current certifications compliant with ASME Boiler and Pressure Vessel Code Section IX. State of Alaska Boiler Inspection: All repairs must be inspected and formally accepted by a certified State of Alaska Boiler Inspector. The contractor is solely responsible for scheduling and funding these inspections prior to invoice submittal. Part II: Industry Feedback & PWS Comments Identify any ambiguities, restrictive requirements, or commercial standard misalignments in the attached draft PWS (Attachment 1). Provide feedback on proposed NAICS classification and potential subcontracting/teaming arrangements 5. SUBMISSION INSTRUCTIONS Format: Electronic submission in Adobe PDF format via email. Due Date & Time: All responses must be received no later than 10/30/2026 at 16:00 AKST. Point of Contacts: Contract Specialist: Name: John Jockusch Email: john.jockusch.3@us.af.mil Phone: (907) 377-5371 Contracting Officer: Name: Brandon Gilbert Email: brandon.gilbert.9@us.af.mil Phone: (907) 377-5080 Email Subject Line: FA500427 - Sources Sought Response: Eielson CHPP Boiler Repair - [Company Name] 6. ATTACHMENTS TO THIS SAM.GOV POSTING Attachment 1 – Draft Performance Work Statement (PWS): CHPP Boiler Repair Services, Eielson AFB
-Market Research10/30/2026
The Contractor shall provide all personnel, supervision, equipment, tools, test instruments OEM replacement parts, materials, and non-personal services necessary to perform semi-annual inspections, operational testing, preventative maintenance, winterization/de-winterization, and repairs on the Fire Department (FD) Helicopter Trainer (O-100), Structural Trainer (T-500), and Aircraft/Hose Line Trainer (O-100) (collectively referred to as the Automated Fire Training Facility (AFTF) or "Live-Fire Trainers"). The goal is to ensure the facilities remain fully operational and serviceable. The Contractor must perform all work according to the manufacturer’s recommendations, relevant technical orders (TOs), all applicable local, state, and federal guidelines, and National Fire Protection Association (NFPA) standards.
-Solicitation11/27/2026
PURPOSE: The purpose of the sources sought is to identify available authorized businesses to provide the requirement for a Crane Load Test at Fairchild AFB. This sources sought notice is for informational and planning purposes only. Pricing information is not being requested at this time. It does not constitute a solicitation and is not to be considered as a commitment by the Government. REQUIREMENT: This notice is issued by the U.S. Air Force, 92d Contracting Squadron, Fairchild AFB, WA. This sources sought is seeking to identify responsible potential sources to test the cranes rated capacity to 125% for the MXS squadron on Fairchild AFB. The Crane Load Test must meet the specifications in accordance with the attached Statement of Work. ANTICIPATED NAICS/SIZE STANDARD: This requirement falls under the NAICS Code of is 811310, Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance, a size standard of $12.5. SUBMISSION OF INFORMATION: All firms responding to this sources sought notice are advised that their response to this notice is not a request that will be considered for contract award. All interested parties will be required to respond to the resultant solicitation separately from their response to this sources sought notice. A responsible potential sources shall have registered with the System for Award Management (SAM). The response should be no more than five pages providing the following information: Specifications of the MXS Crane Load Test Business name, address, CAGE code Size and socioeconomic classification based on NAICS size standard If claiming a specific small business category, provide supporting documentation Point of contact including email and phone number Please respond to this request by 19 November 2026 at 10:00 AM Pacific Time
-Market Research11/19/2026
Please see the solicitation and its attachments. Submit quote to POCs listed below.
-Solicitation11/20/2026

Additional Details

Solicitation Number

FA500024Q0014

Archive Date

Aug 13, 2024

Office Address

JBER, AK, 99506-2501