Notice ID: 363dbba5e0124e09a6fdec11a0fcbeb2SolicitationArchived
Repair Transformers Upgrade Lighting Okuma
Archived on May 30, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 3:30 PM PDT
- Posted
- May 29, 2025
- Notice type
- Solicitation
- NAICS
- 334416: Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing
- Agency
- Department of WarDepartment of the Air Force
Notice details
- Office
- FA5270 18 CONS PK
- Place of performance
- B116 North Beach Road Okuma, Kunigami, Kunigami District,Okinawa Prefecture 905-1412 Japan, 96863
- Last updated
- Nov 12, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- FA527025R0010
- Notice ID
- 363dbba5e0124e09a6fdec11a0fcbeb2
Description
Work will include, but not limited to, removal and replacement of the existing TH-6 and TH-7 electrical system and area lighting at Okuma. Demolish the old transformer house buildings #6 and #7. Replace the existing pole mounted transformers inside of TH-6 and TH-7 with US type outdoor transformer units. New transformers will be concrete pad mounted with footings, mountings, and decorative wall enclosure. Wiring will be rerouted as required to connect power to new transformers. Demolition and dispose of existing transformers, exteriorenclosures, concrete and wooden poles, and lighting include all conduits, conductors, and controls. New transformers will be equipped with new secondary main distribution panels that will include lighting control panels in transformer enclosure. The new outdoor transformer units will sit on new concrete pads with additional handholes. All existing transformers are contaminated with Polychlorinated Biphenyls (PCBs) therefore abatement and disposal of toxic materials must comply with all Government of Japan and Federal rules and regulations. Provide all work and appurtenances for a complete and usable facility. Laydown areas to be determined. This project will comply with applicable DoD, Air Force and base design standards. Sustainable principles, to include life cycle cost-effective practices, will be integrated into the design, development, and construction of the project in accordance with UFC 1-200-02. Project design is 0% complete as of 20 Jul 2023
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
Links (4)
- PIEE Solicitation Module Link for FA527025R0010piee.eb.milPosted
- Web Based Training for the PIEE Solicitation Modulepieetraining.eb.milPosted
- Registration Instructions for the PIEE Solicitation Modulewww.acq.osd.milPosted
- Department of Defense Procurement Toolboxdodprocurementtoolbox.comPosted
Lifecycle
- 1Version 1SolicitationArchived
Repair Transformers Upgrade Lighting Okuma
- 2Version 2SolicitationArchived
Repair Transformers Upgrade Lighting Okuma
- 3Version 3SolicitationArchived
Repair Transformers Upgrade Lighting Okuma
- 4Version 4SolicitationArchived
Repair Transformers Upgrade Lighting Okuma
- 9Version 9SolicitationArchivedCurrent
Repair Transformers Upgrade Lighting Okuma
- 7Version 7Award NoticeArchived
Type changed from Solicitation to Award Notice
Repair Transformers Upgrade Lighting Okuma
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
FA527025R0010
Archive Date
May 30, 2026
Office Address
APO, AP, 96368-5199