VLF Voltage Testing
Archived on August 21, 2026. Original response deadline: . Full description on SAM.gov.
Description
SOURCES SOUGHT NOTICE
Project Title: VLF Testing of Medium Voltage Power Lines
Location: 911th Air Force Reserve Base / Pittsburgh Air Reserve Station (ARS)
Notice Type: Sources Sought / Request for Information (RFI)
1. Introduction
This Sources Sought notice is being posted in accordance with Request for Offers (RFO) procedures and Federal Acquisition Regulation (FAR) Part 10, Market Research, requirements.
This is a Request for Information (RFI) ONLY to conduct market research and determine the availability and technical capability of qualified businesses to provide the required services. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The Government does not intend to award a contract on the basis of this Sources Sought notice or to otherwise pay for the information solicited.
2. Project Description
The 911th Air Force Reserve Base (Pittsburgh ARS) is seeking capable and qualified contractors to provide all materials, labor, and equipment necessary to perform Very Low Frequency (VLF) Testing of Medium Voltage Power Lines. The primary objective is to verify the integrity and insulation strength of the designated power lines to ensure safe and reliable operation.
There are an estimated 75 locations that will need to be tested on base.
Key work elements include, but are not limited to:
- Developing and executing a comprehensive VLF testing plan demonstrating that the system meets or exceeds IEEE 400.2 standards.
- Conducting site surveys, equipment preparation, and Lockout/Tagout (LOTO) procedures.
- Performing VLF testing (0.01 Hz to 0.1 Hz) and insulation resistance testing (IAW IEEE 43).
- Isolating circuits, identifying potential insulation weaknesses, and resolving defects (repair or replace damaged equipment).
- Providing a comprehensive report in digital spreadsheet format outlining test results, leakage current readings, defect records, and definitive Pass/Fail determinations.
The anticipated Period of Performance is 300 days from the Notice to Proceed (NTP).
3. Contractor must follow these Requirements
All installation, testing, and materials must be completed by qualified personnel certified in VLF testing and medium voltage cable testing. Work must be performed in accordance with the latest versions of applicable standards, including:
- DoD Unified Facility Criteria (UFC) (that we can provide)
- Air Force Engineering Technical Letters (that we can provide)
- National Fire Protection (NFPA-70, NFPA-70B)
- Institute of Electrical and Electronics Engineers (IEEE 400.2, 400-2012, IEEE 43)
- International Electrical Testing Association (NETA)
- State and Federal OSHA regulations
Contractors must also comply with base access requirements, including background checks for passes and Commercial Vehicle Inspections.
4. Requested Information (Capability Statement)
Interested parties are requested to submit a Capability Statement addressing the following:
- Company Profile: Company name, address, Point of Contact (POC), phone number, email, CAGE Code, and Unique Entity ID (UEI).
- Socio-Economic Status: Specify any applicable small business classifications (e.g., 8(a), HUBZone, Service-Disabled Veteran-Owned, Women-Owned).
- Technical Capability: A brief statement detailing your company's ability to perform the VLF testing as described, including the capability to service the estimated 75 locations within the 300-day performance period.
- Certifications: Confirmation that personnel are properly trained and hold necessary VLF and medium voltage testing certifications.
- Past Performance: Brief examples of similar work performed in the past three (3) years, preferably on military installations or large commercial facilities.
5. Submission Instructions
All responses to this Sources Sought notice must be submitted electronically to the Contracting Office via email at Ryan.Scott.34@us.af.mil and Crystal.Spurlin@us.af.mil no later than 12:00 PM on 08/6/2026. Please include "Sources Sought Response: VLF Testing - Company Name and CAGE CODE" in the subject line.
Disclaimer: Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.
Overview
Award Overview
Possible prior contracts
Sign in to see possible prior contracts for this requirement (matched by agency, NAICS and place of performance; not confirmed).
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
Showing 2 of 2 items
Document | Source | Agency | Posted Date | File Size | Actions | |
|---|---|---|---|---|---|---|
| Sources Sought | DEPT OF THE AIR FORCE | Jul 28, 2026 | 29.32 KB | |||
| Sources Sought | DEPT OF THE AIR FORCE | Jul 28, 2026 | 33.82 KB |
Lifecycle
FA6712VoltageTestingVLF- Market Research
Pre-solicitation or formal solicitation typically follows within 30–180 days. (estimate)
- Market ResearchCurrentJul 28, 2026
VLF Voltage Testing
Similar Opportunities
Title | Phase | Agency | NAICS | Set Aside | Posted | Deadline | Location |
|---|---|---|---|---|---|---|---|
VLF (Very Low Frequency) Testing Power Lines FA671226Q0014 Attachments: #1 = Statement of Work #2= Price schedule please use for quote #3 = Wage Determination #4 = RFQ (Request for Quotation) **Amended name of attachment and changed the description. | Solicitation | 541380 | Total Small Business Set-Aside | 08/11/2026 | 08/21/2026 | - | |
See Attachment 4 | Solicitation | 541380 | Total Small Business Set-Aside | 08/10/2026 | 08/21/2026 | - | |
The program will continue to save the government money if monthly inspections and annual calibrations are performed. | Awarded | 541380 | Total Small Business Set-Aside | 09/28/2026 | Open | San Joaquin, CA | |
PROJECT DESCRIPTION: The U.S. Army Corps of Engineer (USACE), Philadelphia District (NAP), anticipates a requirement for a firm fixed-price service contract for this acquisition to procure services to perform ultrasonic thickness testing on the cast piping located in the Pump Room, on the side shell within the Pump Room, and in the Engine Room for the Dredge McFARLAND. BASIS FOR SELECTION OF AWARD: Award shall be made to the offeror who is has the lowest price meeting the technical requirements. Quote must meet or exceed the statement of work and delivery schedule to be considered for award.. QUOTE SUBMISSION: Offerors shall submit their quotes no later than the time and date specified in Block 8 of the SF 1449 of this solicitation or the latest amendment (if applicable) as follows: The Offerors quote shall be submitted electronically via Procurement Integrated Enterprise Environment (PIEE), as described below. The Offerors quote shall not contain classified data. The use of hyperlinks in bids is prohibited. NOTE: The only authorized transmission method to this solicitation is electronically via PIEE Solicitation Module online submission. NO OTHER TRANSMISSION METHODS (EMAIL, FACSIMILIE, REGULAR MAIL, HANDCARRIED, ETC.,) WILL BE ACCEPTED.ADDITIONAL INFORMATION: Specific information pertaining to this procurement is available in the Solicitation. The Solicitation documents are posted on the SAM.gov website. It is, and will continue to be, the responsibility of all potential Offerors to monitor the SAM.gov website for any amendments, updates, responses to industry questions/comments, etc. The Government will not be maintaining a mailing list. POINT-OF-CONTACT: The Primary Contract Specialist for this Solicitation is Matthew Rhoads at matthew.t.rhoads@usace.army.mil. Any communication regarding this notice should be made in writing sent via email and must identify the Solicitation number, company name, address, phone number and point of contact. | Solicitation | 541380 | Total Small Business Set-Aside | 01/22/2026 | 02/05/2026 | - | |
The contractor shall provide all parts, labor, materials, supplies, equipment, transportation, and services necessary to collect drinking water samples on Hurlburt Field, transport them to the contract laboratory, and analyze such samples, including resampling. Services must conform to all, most current, applicable federal regulations and Florida Administrative Codes (F.A.C.). This work is required in accordance with (IAW) Safe Drinking Water Act; Rule 62-550, F.A.C.; Drinking Water Standards; Rule 62-560, F.A.C.; Requirements for Public Water System that are out of Compliance and Department of Defense Instruction 4715.6, and Environmental Compliance. All sampling technicians will follow all applicable Department of Environmental Protection (DEP) Standard Operating Procedures. Amendment 0001: upload Q&A and extend the proposal submission due date. Amendment 0002: Upload additional Q&A and the solicition provisions, clauses, and CLIN structure due to error in system deleting them. Upload an updated SOW. | Combined Synopsis | 541380 | Total Small Business Set-Aside | 09/22/2026 | 10/02/2026 | - |
Additional Details
Solicitation Number
FA6712VoltageTestingVLF
Archive Date
Aug 21, 2026
Office Address
CORAOPOLIS, PA, 15108-4495