GovChime
Notice ID: 53870556e907401bad0acac6d61f5529Combined Synopsis/Solicitation

Plasma Spray Booth Cleaning Services

Archived on November 8, 2024. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM UTC−05:00
Posted
October 21, 2024
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Agency
Department of WarDepartment of the Air Force

Notice details

Office
FA8132 AFSC PZIMC
Place of performance
Tinker AFB, 73145
Last updated
Jan 23, 2026

Identifiers

Solicitation number
FA813224Q0054
Notice ID
53870556e907401bad0acac6d61f5529

Description

DUE DATE EXTENDED to 24 October 2024 SITE VISIT QUESTIONS & ANSWERS: 1. Are contract employees required to have an on-call spill response capability in the event of a spill outside of 1500-2300 (Swing Shift) working hours? Contractors shouldnt be on site outside of working hours, but there is a spill number listed in the shop near the hazardous waste containers and drain. 2. Is there any requirement for a contractor provided vehicle to transport equipment between Building 3001 and Building 3221? There isnt any specific requirement, must follow common base rules. 3. Does the government provide a location to store Contractor Personal Protective Equipment on site or will Contractor be required to bring PPE on site and remove daily? Accommodations can be discussed, but I believe past contractors brought their own PPE and didnt store it here. 4. The PWS references Contractor-provided brooms, dustpans, mops, etc will be stored in a locked cabinet. Is there a dedicated cabinet located on site to store this equipment? Yes the government can find a dedicated area or closet of some kind 5. The PWS, 1.3.3, mentions non-reflective black or gray peel coat paint. Is Clear or Translucent acceptable? Yes 6. What is the approximate weight and size of the 76 PMXGs HEPA vacuums which 1.2.7 references are the responsibility of the Contractor to empty periodically? Roughly 30-40 lbs 7. PWS 1.3.1 (Floor Cleaning). When floor is mopped/power scrubbed during the quarterly cleaning, are there any special requirements for disposing of the contaminated/dirty water? Is it drummed or can it be disposed of down the drain to the IWTP? Does it require approval IAW 1.17 during each quarterly cleaning? There is a hazardous waste drain in the shop that is used weekly by operators. This will be where the liquid waste goes. Due date extended to 22 October 2024 to allow for questions and answers which will be posted as an Amendment 2. Amendment 1 to the CSS adds SITE VISIT information and EXTENDS quote due dates Cleaning Services for Plasma Spray Booths, Plasma Spray Booth Dust Collectors, and Grit Blast Dust Collectors In Accordance With (IAW) the Performance Work Statement (PWS).

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Select documents to download

Showing 7 of 7 items

Document
Source
Agency
Posted Date
File Size
Actions
Combined Synopsis/SolicitationDEPT OF THE AIR FORCEOct 21, 2024-
Combined Synopsis/SolicitationDEPT OF THE AIR FORCEOct 21, 2024-
Combined Synopsis/SolicitationDEPT OF THE AIR FORCEOct 21, 2024-
Combined Synopsis/SolicitationDEPT OF THE AIR FORCEOct 21, 2024-
Combined Synopsis/SolicitationDEPT OF THE AIR FORCEOct 21, 2024-
Combined Synopsis/SolicitationDEPT OF THE AIR FORCEOct 21, 2024-
Combined Synopsis/SolicitationDEPT OF THE AIR FORCEOct 21, 2024-

Lifecycle

Solicitation:FA813224Q0054
  1. Combined Synopsis
  1. 6×
    Combined SynopsisCurrentSep 24, 2024

    Plasma Spray Booth Cleaning Services

    Notice 53870556e907401bad0acac6d61f5529 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

FA813224Q0054

Archive Date

Nov 8, 2024