Repair of Voltage Regulator for the MUTES Program NSN 6110008799800
Archived on March 28, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 5:00 PM MDT
- Posted
- March 3, 2026
- Notice type
- Solicitation
- NAICS
- 811210: Electronic and Precision Equipment Repair and Maintenance
- Agency
- Department of WarDepartment of the Air Force
Notice details
- Office
- AIR FORCE MATERIEL COMMAND.AIR FORCE SUSTAINMENT CENTER.FA8250 AFSC PZAAA
- Last updated
- Nov 2, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- FA825026Q0478
- Notice ID
- ab1a5f98698e47098d845171d181146d
Description
This effort is sole source to Potomac Electric.
Please review the Performance Work Statement (PWS) for details.
NOTE: It is the responsibility of the offeror to ensure their proposal has been successfully emailed to the Primary Contact of this contract opportunity. After sending an email with your proposal please send another email with no attachments to verify the Primary Contact received your proposal. Please review all documents thoroughly. If there are any questions please don't hesitate to email the Primary Contact.
PR Number(s): FD20202600478
Line Item: 0001
NSN: 6110008799800FD REGULATOR,VOLTAGE
P/N: 1571-9898, P/N: 1571AL2, P/N: 650059,
Description: Single phase 115V nom.
Supp. Description: Electronics, metal
Quantity: 9.0000 EA
Applicable to: None
Delivery: *30 Days *ARO After Receipt of Carcass
Destn: PLANT,, , .
Quantity: 9.00
Unit of Issue: EA
PR Number(s): FD20202600478
Line Item: 0002
NSN: 6110008799800FD REGULATOR,VOLTAGE
P/N: 1571-9898, P/N: 1571AL2, P/N: 650059,
Description: Single phase 115V nom.
Supp. Description: Electronics, metal
Quantity: 9.0000 EA
Applicable to: None
Delivery: *30 Days *ARO After Completion of Study
Destn: SW3114,TOBYHANNA PA 18466-5059,PA ,18466-5059.
Quantity: 9.00
Unit of Issue: EA
PR Number(s): FD20202600478
Line Item: 0003
Data
Description: IAW DD FORM 1423-1 DATA ITEM NO. A001, A002, A003 COMMERCIAL ASSET VISIBILITY AIR FORCE REPORTING
Quantity: 1.0000 EA
Delivery: *24 Hours *ARO following a supply or maintenance transaction
Destn: FB2029,HILL AFB UT 84056,49 ,84056-4056.
Quantity: 1.00
Unit of Issue: EA
PR Number(s): FD20202600478
Line Item: 0004
Data
Description: IAW DD FORM 1423-1 DATA ITEM NO. B001 REPAIRABLE ITEM INSPECTION REPORT
Quantity: 2.0000 EA
Delivery: *7 Calendar Days *ARO after completion of the contract
Destn: FY2073,HILL AFB UT 84056-5820,49 ,84056-5820.
Quantity: 2.00
Unit of Issue: EA
PR Number(s): FD20202600478
Line Item: 0005
Data
Description: IAW DD FORM 1423-1 DATA ITEM NO. C001 COUNTERFEIT PROTECTION PROGRAM
Quantity: 2.0000 EA
Delivery: *30 Calendar Days *ARO after contract award
Destn: FY2073,HILL AFB UT 84056-5820,49 ,84056-5820.
Quantity: 2.00
Unit of Issue: EA
PR Number(s): FD20202600478
Line Item: 0006
Data
Description: IAW DD FORM 1423-1 DATA ITEM NO. D001 ENGINEERING CHANGE PROPOSAL
Quantity: 3.0000 EA
Delivery: *14 Calendar Days *ARO after the completion of test, teardown and evaluation, AS NEEDED
Destn: FY2073,HILL AFB UT 84056-5820,49 ,84056-5820.
Quantity: 3.00
Unit of Issue: EA
Electronic procedure will be used for this solicitation.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Files (17)
- Download
FA825026Q0478.pdf
1.1 MBAdded in Solicitation version 3Posted - Download
CONTRACT_DATA_REQUIREMENTS_LIST.pdf
858 KBAdded in Solicitation version 3Posted - Download
PERFORMANCE_WORK_STATEMENT.pdf
347 KBAdded in Solicitation version 3Posted - Download
SSJ_Redacted.pdf
223 KBAdded in Solicitation version 3Posted - Download
CAVAF_REPORTING_REQUIREMENTS.docx
218 KBAdded in Solicitation version 3Posted - Download
DI-PSSS-81995A_A002_CDM_Production_Report.pdf
190 KBAdded in Solicitation version 3Posted - Download
PACKAGING_STATEMENT_OF_WORK.pdf
128 KBAdded in Solicitation version 3Posted - Download
TRANSPORTATION.pdf
93 KBAdded in Solicitation version 3Posted - Download
DI-MGMT-80441_A003_Government_Property_Inventory_Report.pdf
143 KBAdded in Solicitation version 3Posted - Download
ITEM_UNIQUE_ID.pdf
59 KBAdded in Solicitation version 3Posted - Download
REPAIR_DATA_LIST.pdf
54 KBAdded in Solicitation version 3Posted - Download
PACKAGING_REQUIREMENT.pdf
76 KBAdded in Solicitation version 3Posted - Download
DI-SESS-80639E_ECP.pdf
121 KBAdded in Solicitation version 3Posted - Download
ITEM_DESCRIPTION.pdf
57 KBAdded in Solicitation version 3Posted - Download
DI-PSSS-80386A_RIIR.pdf
44 KBAdded in Solicitation version 3Posted - Download
DI-MGMT-81838_A001.pdf
17 KBAdded in Solicitation version 3Posted - Download
DI-MISC-81832_CPP.pdf
41 KBAdded in Solicitation version 3Posted
Lifecycle
- 3Version 3SolicitationArchivedCurrent
Repair of Voltage Regulator for the MUTES Program NSN 6110008799800
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
FA825026Q0478
Archive Date
Mar 28, 2026