GovChime
Notice ID: 1136724f8b7547b0b34908c3d3a36b15Combined Synopsis/SolicitationArchived

L7-090 Repair and Liner - Chemical Storage Tanks

Archived on July 17, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
2:00 PM EDT
Posted
July 1, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
No Set aside used
NAICS
238990: All Other Specialty Trade Contractors
Agency
Department of WarDepartment of the Air Force

Notice details

Office
AIR FORCE MATERIEL COMMAND.AIR FORCE SUSTAINMENT CENTER.FA8571 MAINT CONTRACTING AFSC PZIM
Place of performance
Georgia, 31098
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
FA857126Q0087
Notice ID
1136724f8b7547b0b34908c3d3a36b15

Description

This solicitation is being conducted under Simplified Acquisition Procedures (SAP) as a Request for Quote (RFQ) No. FA857126QOO87. This requirement is being solicited as a single source requirement to the Original Equipment Manufacturer (OEM) for the repair of L7-090 Liner and purchase of one (1) additional L7-090 Liner.

The Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.

The Contractor shall provide the following:
• Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs.
• 1 each (PVDF) Kynar® Rigid Box Liner to fit CMXG’s existing tank
• Approximately 48” x 48” x 72” deep, fabricated from ¼” thick Kynar 2850 Flex sidewalls and rim and 3/8” thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System

Amendment 0001 corrects Period of Performance for CLIN 0002 and adjust responses due date to account for the High Priority need of this effort.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Files (10)

  • Solicitation Amendment FA857126Q00870001 SF 30.pdf

    375 KBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • FA857126Q0087.pdf

    5.2 MBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • 2015-4995.pdf

    352 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • 82035 - CDRL A002 - Status Report_EMS Training.pdf

    253 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • 82035 - CDRL A003 - Status Report_EnMS Training.pdf

    255 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • 82035 - CDRL A001 Technical Data Package.pdf

    247 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • 82035 - Appendix C- BAF 82035 L7-090 Liner and Repair Builidng 20128.pdf

    267 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • 82035 - Performance Work Statement (PWS) (1).pdf

    237 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • 82035 - CDRL A004 - Contractors Safety Plan.pdf

    253 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • 82035 - CDRL A005 - Accident Incident Report.pdf

    252 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationArchived

    L7-090 Repair and Liner - Chemical Storage Tanks

    Notice ab59222407c14f72933ae2eef50345b3 on SAM.gov

  2. 2
    Version 2Combined Synopsis/SolicitationArchived

    L7-090 Repair and Liner - Chemical Storage Tanks

    Notice 9ccb25f96127440fbdca899e63feb212 on SAM.gov

  3. 4
    Version 4Combined Synopsis/SolicitationArchivedCurrent

    L7-090 Repair and Liner - Chemical Storage Tanks

    Notice 1136724f8b7547b0b34908c3d3a36b15 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

FA857126Q0087

Archive Date

Jul 17, 2026

Office Address

ROBINS AFB, GA, 31098-1672