GovChime
Notice ID: 0e81f2e8ea4f4e07bef4f4022a17087eCombined Synopsis/Solicitation

S-Series Closed Loop Air Chiller

Archived on January 20, 2026. Original response deadline: . Full description on SAM.gov.

Description

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation being issued; quotes are being requested and a written solicitation will not be issued. This solicitation is being conducted under Simplified Acquisition Procedures (SAP) as a Request for Quote (RFQ) No. FA857126QA002. This requirement is being solicited as a single source requirement to the Original Equipment Manufacturer SOLE SOURCE TO: Dimplex Thermal Solutions, Inc CAGE Code: 4SWG1

Full description on SAM.gov

Overview

Agency:
Department of WarDepartment of the Air Force
Office:FA8571 MAINT CONTRACTING AFSC PZIM
Posted:December 19, 2025
NAICS:333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Last Updated:Sep 25, 2026
PSC:4120: AIR CONDITIONING EQUIPMENT
Set-Aside:Not specified
Type:Combined Synopsis/Solicitation
Place of Performance:Warner Robins, Georgia, 31098

Award Overview

Possible prior contracts

Sign in to see possible prior contracts for this requirement (matched by agency, NAICS and place of performance; not confirmed).

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Select documents to download

Showing 3 of 3 items

Document
Source
Agency
Posted Date
File Size
Actions
Combined Synopsis/SolicitationDEPT OF THE AIR FORCEDec 19, 2025183.5 KB
Combined Synopsis/SolicitationDEPT OF THE AIR FORCEDec 19, 2025191.53 KB
Combined Synopsis/SolicitationDEPT OF THE AIR FORCEDec 19, 2025251.53 KB

Lifecycle

Solicitation:FA857126QA002
  1. Combined Synopsis
  1. 2×
    Combined SynopsisCurrentDec 19, 2025

    S-Series Closed Loop Air Chiller

    Notice 0e81f2e8ea4f4e07bef4f4022a17087e on SAM.gov

Similar Opportunities

Title
Phase
Agency
NAICS
Set Aside
Posted
Deadline
Location
This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number FA441726Q0205 is issued as a RFQ, for TRANE CHILLERS. This acquisition is set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.govFunds are not presently available for this effort. No award will be made under this solicitation until funds are available. Requesting estimated delivery dates. All quotes must be valid through 30 September 2026. -One (1) 30 Ton Air-Cooled (CGAM) Model number: CGAM030A2**3EXD2A1A3A1DX*A1D2B4XXAXXXB1A3A1D1XXLXX; -One (1) 52 Ton Air-Cooled (CGAM) Model number: CGAM052A2**3EXD2A1A3A1DX*A1D2B4XXAXXXB1A3A1D1XXLXX.
Combined Synopsis333415Total Small Business Set-Aside08/20/202608/25/2026-
Air-cooled scroll chiller manufactured by Trane, model name Ascend ASCA, model number ACSA2002EUA*XEXLXNB2XLNWSMEX1CAXBXXAA1XXXXONX to be installed through other means and methods at Seymour Johnson Air Force Base, North Carolina. All solicitation documents may be accessed via the ?PIEE Solicitation Module Link for FA480926Q0047? under the Attachments/Links menu at SAM.gov. Submission of quote via the PIEE Solicitation Module is preferred to ensure timely/reliable submission; however, quotes may also be submitted via email. Emailed quotes should be addressed to BOTH points of contact with FA480926Q0047 referenced in the subject line. Prospective offerors are advised that late quotes, to include those potentially delayed due to government firewall restrictions, may be determined unresponsive and removed from evaluation consideration.
Solicitation333415Women-Owned Small Business Program Sole Source06/16/202606/29/2026-
Sources Sought Synopsis Serv C26-134 Daily Freezer Replacement (Lay Up Room) Tinker Air Force Base, OK 14 September 2026 Serv C26-134 Daily Freezer Replacement (Lay Up Room) CAUTION: This market survey is being conducted to identify potential sources that may possess the expertise, capabilities, and experience to meet the requirements for qualification and production of the Serv C26-134 Daily Freezer Replacement (Lay Up Room) for use by United States Air Force (USAF) personnel. The level of security clearance and amount of foreign participation in this requirement has not been determined. Contractors/Institutions responding to this market research are placed on notice that participation in this survey may not ensure participation in future solicitations or contract awards. The government will not reimburse participants for any expenses associated with their participation in this survey. INSTRUCTIONS: Below is a document containing a description of the Serv C26-134 Daily Freezer Replacement (Lay Up Room) requirement and a Contractor Capability Survey, which allows you to provide your company’s capability. Performance Work Statement (PWS) If, after reviewing these documents, you desire to participate in the market research, you should provide documentation that supports your company’s capability in meeting these requirements. Failure to provide documentation may result in the government being unable to adequately assess your capabilities. If you lack sufficient experience in a particular area, please provide details explaining how you would overcome the lack of experience/capabilities in order to perform that portion of the requirement (i.e., teaming, subcontracting, etc.) Identify any areas of work that your organization believes should be broken out exclusively for Small Business. Both large and small businesses are encouraged to participate in this Market Research. Joint ventures or teaming arrangements are encouraged. Questions relative to this market survey should be addressed to Tori Wallace, 405-734-0453 and tori.wallace@us.af.mil Serv C26-134 Daily Freezer Replacement (Lay Up Room) PURPOSE/DESCRIPTION The Government is conducting market research to identify potential sources that possess the production data/repair data, expertise, capabilities, and experience to meet qualification requirements for the Daily Freezer Replacement (Lay Up Room) on/for Tinker Air Force Base (AFB). The intent is for the Government to secure a one-year service contract for these services. Scope: The Contractor shall provide all labor, tools, equipment, test equipment, material, parts, quality control, transportation and inspection manuals necessary to perform replacing the existing refrigeration systems for two (2) walk in freezers located in the layup room in Building 9001, Post F-16 the Oklahoma City–Air Logistics Complex (OC-ALC). The equipment is listed in Appendix A (On-Base). The Contractor shall be responsible for ensuring all services, parts and Original Equipment Manufacturer (OEM) components provided under this contract are in accordance with (IAW) the terms and conditions outlined herein, conform to the manufacturer’s equipment specifications and this PWS. The following descriptions are from the attached Performance Work Statement (PWS). Requested Services: The Contractor shall replace the existing refrigeration systems for two (2) walk-in freezers. The new refrigeration systems must be fully compatible with the existing electrical setup, power requirements (Single‑phase, 208 V, 60 Hz), and freezer box panels (9 ft × 9 ft × 8 ft 5 in). No modifications are permitted to the freezer box panels or their disconnect boxes. The existing freezer box panels will be reused. This is a turnkey project, requiring the contractor to provide all labor, materials, equipment, and services necessary to deliver fully operational systems capable of maintaining a –10°F setpoint. 3. Contractor Responsibilities (Turnkey Scope) 3.1 Refrigeration Requirement Evaporator Unit Requirement Shall be electric-defrost evaporator assembly, model EL26‑079‑2EC‑PR‑A or equivalent and be suitable for low‑temperature walk‑in applications Shall be using low‑GWP A2L refrigerant and meets the EPA’s 2026 requirements for new commercial refrigeration systems. Prefer R454A refrigerant. Performance requirements: Cooling Capacity: 7,900 BTUH Airflow: 1,600 CFM Annual Walk‑In Energy Factor of 4.00 Btu/W‑h Operating Modes: Off‑cycle, air defrost w/timer, electric defrost, demand electric defrost Electrical Requirements: Power Supply: 208–230V, 1‑phase, 60 Hz Max Total Connected Load: 13.1A Minimum Circuit Ampacity: 15A Maximum Overcurrent Protection: 20A Fan Motors: EC two‑speed motors, 1.0A @ 208–230V or equivalent Defrost Heaters: 13.1A @ 208–230V or equivalent Control Circuit: 24V transformer included Electronic Temperature Control: Required (factory installed) Mechanical Requirements: Suction Connection: 5/8" ODF Liquid Connection: 3/8" ODF Drain Connection: ¾‑14 NPT These following components shall be included with the Unit Expansion valve (factory installed) Digital temperature control (factory installed) EC evaporator fan motors – two‑speed Leak detection – two sensors required (factory installed) Safety shut‑off / liquid line solenoid valve Safety check valve Condenser Unit Requirement Shall be designed for low‑temperature A2L (prefer R454A) refrigeration applications, model PC225ALZOP‑2S or equivalent. Unit shall comply with AHRI 1250 test method Annual Walk‑In Energy Factor of 3.15 or higher. Rating must meet DOE requirements. Performance Requirements: Compressor Model: Copeland YF07KAE‑PFV or equivalent with 2¼ Horsepower Electrical Requirements Power Supply: 208–230V, 1‑phase, 60 Hz Compressor RLA: 12.4A or equivalent Compressor LRA: 88A or equivalent Condenser Fan Motor FLA: 1.1A or equivalent Max Total Unit Amps: 13.7A Minimum Circuit Ampacity (MCA): 16.8A Maximum Overcurrent Protection (MOPD): 25A Mechanical Requirements Total Heat Rejection of 14,209 BTUH or equivalent to maximize the entire system efficiency Refrigerant Piping Requirements Suction Line: 7/8" OD Liquid Line: 3/8" OD Controls & Safety Requirements: Unit shall include the following controls as a minimum High‑pressure control Low‑pressure control High discharge cut‑out switch Time delay relay Fan cycle head pressure control Crankcase heater Electric defrost timer 3.2 Removal and Disposal Pump down and safely remove the existing refrigeration systems from both units. Properly dispose of all removed equipment and refrigerant in accordance with industrial regulations. 3.3 Procurement and Delivery Procure new refrigeration systems compatible with the existing electrical and mechanical configuration. Deliver all equipment to the project site. Provide all required materials, hardware, and accessories. Provide all labor, equipment, materials, and tools required for complete installation. Supply only new, commercially available equipment—no prototype or experimental models. 3.4 Installation Requirements The contractor shall: Meet delivery trucks and off‑load refrigeration equipment. Install new refrigeration condensers and evaporators. Provide nylon all‑thread and stainless‑steel hardware for evaporator coil suspension. Install new ACR hard copper piping and 1" thick‑wall suction line insulation. Provide all unistrut, hangers, brackets, trapeze supports, pipe clamps, all‑thread, and anchors as needed. Provide all fittings, silver solder, welding supplies, and labor required for refrigeration piping. Perform leak checks with nitrogen, pull vacuum, and charge the system with new refrigerant. Perform all electrical work, including: Disconnecting power from existing units Removing conduit and demolition as required Reinstalling receptacles in their current locations Providing new power connections from existing disconnects to the new evaporators and condensing units Mounting and wiring lights Installing new seal‑offs at penetration points and GRC inside the freezers Install drains, furnish and install heat tape (if required), and insulate drain lines. Start up all refrigeration systems, set pressure switches and controls, calibrate thermometers, and verify temperature performance. Seal all refrigeration penetrations. Replace two (2) door gaskets per freezer. 4. System Performance Requirements The completed installation must deliver: Fully operational refrigeration systems Ability to maintain a –10°F setpoint under normal operating conditions Proper integration with existing freezer box panels and electrical infrastructure 5. Startup and Training Requirements The Contractor shall: a. Conduct full system startup and functional testing to verify proper operation of all installed components. 6. Deliverables at Time of Solicitation (Offeror Requirements) The Offeror shall provide: a. Detailed descriptions, specifications, and sketches demonstrating compliance with this Statement of Work (SOW). b. Justification for any proposed alternative solutions, demonstrating how they meet or exceed the requirements. 7. Deliverables at Time of Installation (Contractor Requirements) The Contractor shall provide: a. Fully installed and operational freezers capable of achieving a –10°F setpoint. b. New refrigeration system component drawings. c. All manuals and parts lists associated with the newly installed equipment. d. Operator training and supporting documentation. 8. Schedule Requirements The contractor shall include in the proposal: Lead time for procurement and delivery. Lead time shall not be more than 10 weeks. Service time required to complete installation for both freezers
Market Research333415No Set-Aside09/14/202610/13/20260, OK
Duplex Strainer supply for Minneapolis VA Health Care System. This is a solicitation conducted using FAR Part 12 (Acquisition of Commercial Products and Commercial Services). Solicitation number 36C26327Q0054 is issued as a request for quotes (RFQ). This solicitation is a small business set-aside. This solicitation is a SPECIAL meaning the process is accelerated compared to a normal solicitation. Prospective offerors must be registered and current in the System for Award Management (SAM) database at time of offer to the Government (https://www.sam.gov). Offerors must be registered at SBA Small Business Search at https://search.certifications.sba.gov/ as a small business vendor. Quotes will only be accepted from responsible contractors. The NAICS code for the solicitation is 333415 with a size standard of 1,250 Employees. A list of the contract line items, quantities, and units of measure are listed within the RFQ solicitation documentation to follow. The VA anticipates one Firm Fixed Price award to provide supplies to the Minneapolis VA Health Care System, One Veterans Drive, Minneapolis MN 55417. The period of performance is 11/9/2026 to 3/15/2027 for the base year period of performance. Technical questions on this solicitation are due via e-mail only to Robert Bennett, Contract Specialist, at robert.bennett8@va.gov no later than 4:00 PM on 10/23/2026. Quotes are due at the Contracting Office by 10:00 AM on 10/30/2026. Quotes are required to be emailed to robert.bennett8@va.gov prior to the solicitation closing date and time. It is the responsibility of the offeror to ensure their quote is received in its entirety by the Contracting Officer before the solicitation closing.
Pre-Solicitation333415Total Small Business Set-Aside10/20/202610/30/2026Minneapolis, MN
Duplex Strainer supply for Minneapolis VA Health Care System. This is a solicitation conducted using FAR Part 12 (Acquisition of Commercial Products and Commercial Services). Solicitation number 36C26327Q0054 is issued as a request for quotes (RFQ). This solicitation is a small business set-aside. This solicitation is a SPECIAL meaning the process is accelerated compared to a normal solicitation. Prospective offerors must be registered and current in the System for Award Management (SAM) database at time of offer to the Government (https://www.sam.gov). Offerors must be registered at SBA Small Business Search at https://search.certifications.sba.gov/ as a small business vendor. Quotes will only be accepted from responsible contractors. The NAICS code for the solicitation is 333415 with a size standard of 1,250 Employees. A list of the contract line items, quantities, and units of measure are listed within the RFQ solicitation documentation to follow. The VA anticipates one Firm Fixed Price award to provide supplies to the Minneapolis VA Health Care System, One Veterans Drive, Minneapolis MN 55417. The period of performance is 11/9/2026 to 3/15/2027 for the base year period of performance. Technical questions on this solicitation are due via e-mail only to Robert Bennett, Contract Specialist, at robert.bennett8@va.gov no later than 4:00 PM on 10/23/2026. Quotes are due at the Contracting Office by 10:00 AM on 10/30/2026. Quotes are required to be emailed to robert.bennett8@va.gov prior to the solicitation closing date and time. It is the responsibility of the offeror to ensure their quote is received in its entirety by the Contracting Officer before the solicitation closing.
Solicitation333415Total Small Business Set-Aside10/20/202610/30/2026Minneapolis, MN

Additional Details

Solicitation Number

FA857126QA002

Archive Date

Jan 20, 2026

Office Address

ROBINS AFB, GA, 31098-1672