Notice ID: ad2c482dabed42b4a1c8f76cadf77cf1Award NoticeAwarded
Refuse Services
Awarded on April 7, 2026. Full description on SAM.gov.
Awarded tounder FA875126C0006 (source: SAM.gov award notice)• $733.4K
Description
Refuse solid waste management Services for the Air Force Reserach Labatory and DFAS in Rome, NY as well as Newport and Stockbridge, NY facilities.
Overview
Agency:
Department of WarDepartment of the Air Force
Office:AIR FORCE MATERIEL COMMAND.AIR FORCE RESEARCH LABORATORY.FA8751 AFRL RIKO
Posted:April 8, 2026
NAICS:562111: Solid Waste Collection
Last Updated:Aug 21, 2026
PSC:S205: HOUSEKEEPING- TRASH/GARBAGE COLLECTION
Set-Aside:Total Small Business Set-Aside (FAR 19.5)
Type:Award Notice
Place of Performance:Rome, New York, 13441
Award Date:Apr 7, 2026
Award Amount (SAM.gov award notice):$733.4K
Award Overview
Award Number
FA875126C0006
Award Amount (SAM.gov award notice)
$733.4K
Award Date
Apr 7, 2026
Awardee
Awardee UEI
QMUGDG4RDPN4
Awardee CAGE Code
18P11
Awardee Address
San Antonio, TX 78252, UNITED STATES
Original Solicitation
Notice ID: ad2c482dabed42b4a1c8f76cadf77cf1
Posted Date: Apr 8, 2026
Original Response Deadline: Not specified
Contacts
Contracting Officer
Primary Contact
Tabitha Haggart
Secondary Contact
Jenna Tarbania
Documents
No documents available.
Lifecycle
Solicitation:
FA875126C0006- Awarded
This opportunity has been awarded.
Similar Opportunities
Title | Phase | Agency | NAICS | Set Aside | Posted | Deadline | Location |
|---|---|---|---|---|---|---|---|
| Awarded | 562111 | Total Small Business Set-Aside | 08/20/2026 | Open | - | ||
| Awarded | 562111 | Total Small Business Set-Aside | 08/20/2026 | Open | - | ||
| Awarded | 562111 | Total Small Business Set-Aside | 08/20/2026 | Open | - | ||
Reason for amendment is to clarify dumpster type and delivery location. Type: Box Style. Capacity: Minimum 30 cubic yards (22.94 cubic meters). Dimensions: Minimum 22 ft (6.71 m) length x 8 ft (2.44 m) width x 6 ft (1.83 m) height. Color: Milford Brown or closest available match. Structural Welding: Must conform to AWS D1.1 American Society Structural Welding Code - Steel. Understructure: Minimum 3 in. (76 mm) structural channel, 4.1 lbs./ft (6.1 kg/m), spaced at 1.75 in. (44 mm) on center. Long Rails: Minimum 2 in. x 6 in. x � in. (51 mm x 152 mm x 6 mm) rectangular tubing. Bullnose: Minimum solid 1 � in. (32 mm) plate burnout. Floor: Minimum 10-gauge steel with reinforced 3 in. (76 mm) channels on 18 in. (457 mm) centers. Push Plate: Minimum 26 in. x 16 in. x 3/16 in. (660 mm � 406 mm � 5 mm) steel plate. Hook Plate: Minimum 23 in. x 15 in. x � in. (584 mm � 381 mm � 19 mm) steel plate. Top Snatch Hook: Positioned at 62 in. (1,575 mm) height (A-frame configuration). Wheels: Minimum 8 in. diameter x 10 in. length (203 mm x 254 mm). Wheel Axles: Minimum of 1-� in. (38 mm) solid round bar with grease fittings. Tailgate Hinges: Minimum of three (3 steel hinges each designed for high-load applications and equipped with grease fittings. Side Walls, Bulkhead, and Tailgate: Minimum 10-gauge steel. Top Rail: Minimum 4 in. x 4 in. x � in. (102 mm � 102 mm � 6 mm) rectangular tubing. Front Posts: Minimum 2 in. x 5 in. (51 mm � 127 mm) formed steel. Rear Corner Post: Minimum 3-� in. x 7 in. x 3/16 in. (89 mm � 178 mm � 5 mm) formed steel. Tailgate Frame: Minimum 3 in. x 4 in. x 7-gauge (76 mm � 102 mm � ~4.6 mm) rectangular tubing. Tailgate Latch: Vertical lift handle required. Materials Standard: All structured steel shall be ASTM A36 American Society for Testing and Materials Specification A36 and conform to AISC American Institute of Steel Construction ?Specifications for Design, Fabrication, and Erection of Structural Steel Buildings? requirements. Delivery to zip code 84074, Tooele Army Depot. | Combined Synopsis | 562111 | Total Small Business Set-Aside | 11/13/2025 | 11/19/2025 | - | |
Capacity: Minimum 30 cubic yards (22.94 cubic meters).Dimensions: Minimum 22 ft (6.71 m) length x 8 ft (2.44 m) width x 6 ft (1.83 m) height.Color: Milford Brown or closest available match.Structural Welding: Must conform to AWS D1.1 American Society Structural Welding Code - Steel. Understructure: Minimum 3 in. (76 mm) structural channel, 4.1 lbs./ft (6.1 kg/m), spaced at 1.75 in. (44 mm) on center.Long Rails: Minimum 2 in. x 6 in. x � in. (51 mm x 152 mm x 6 mm) rectangular tubing.Bullnose: Minimum solid 1 � in. (32 mm) plate burnout. Floor: Minimum 10-gauge steel with reinforced 3 in. (76 mm) channels on 18 in. (457 mm) centers.Push Plate: Minimum 26 in. x 16 in. x 3/16 in. (660 mm � 406 mm � 5 mm) steel plate. Hook Plate: Minimum 23 in. x 15 in. x � in. (584 mm � 381 mm � 19 mm) steel plate. Top Snatch Hook: Positioned at 62 in. (1,575 mm) height (A-frame configuration).Wheels: Minimum 8 in. diameter x 10 in. length (203 mm x 254 mm). Wheel Axles: Minimum of 1-� in. (38 mm) solid round bar with grease fittings.Tailgate Hinges: Minimum of three (3 steel hinges each designed for high-load applications and equipped with grease fittings. Side Walls, Bulkhead, and Tailgate: Minimum 10-gauge steel.Top Rail: Minimum 4 in. x 4 in. x � in. (102 mm � 102 mm � 6 mm) rectangular tubing. Front Posts: Minimum 2 in. x 5 in. (51 mm � 127 mm) formed steel. Rear Corner Post: Minimum 3-� in. x 7 in. x 3/16 in. (89 mm � 178 mm � 5 mm) formed steel. Tailgate Frame: Minimum 3 in. x 4 in. x 7-gauge (76 mm � 102 mm � ~4.6 mm) rectangular tubing. Tailgate Latch: Vertical lift handle required. Materials Standard: All structured steel shall be ASTM A36 American Society for Testing and Materials Specification A36 and conform to AISC American Institute of Steel Construction ?Specifications for Design, Fabrication, and Erection of Structural Steel Buildings? requirements. | Combined Synopsis | 562111 | Total Small Business Set-Aside | 11/12/2025 | 11/19/2025 | - |
Additional Details
Solicitation Number
FA875126C0006
Archive Date
Apr 22, 2026
Office Address
ROME, NY, 13441-4514