Awarded
Fire Alarm System Testing, Inspection and Repair
Awarded tounder DJF-16-1200-K-0009388 (source: SAM.gov award notice)• $161.0K
Overview
- Posted
- October 5, 2016
- Notice type
- Award Notice
- Agency
- Department of JusticeFEDERAL BUREAU OF INVESTIGATION
Notice details
- Office
- FBI-JEH
- Place of performance
- 1000 Custer Hollow Road, Clarksburg, 26554
- PSC
- J: MAINT, REPAIR, REBUILD EQUIPMENT
- Last updated
- Dec 5, 2025
- Award date
- Sep 30, 2016
- Award amount (SAM.gov award notice)
- $161.0K
Identifiers
- Solicitation number
- FCU-16-0001902
- Notice ID
- 9e2ba503ddbf2e787ffde8afb16ea67e
- Award number (PIID)
- DJF-16-1200-K-0009388
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, "Streamlined Procedures for Evaluation and Solicitation for Commercial Items," as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested, and a written solicitation document will not be issued. This solicitation is a request for quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-87 effective 06 Apr 2016. The complete text of any of the clauses and provisions may be accessed in full text at http://farsite.hill.af.mil. This RFQ is solicited as an unrestricted basis. The associated North American Industrial Classification System (NAICS) code for this procurement is 561621 - Security Systems Services (except Locksmiths) and the size standard is $20.5 million. The FBI does not intend to reimburse recipients of this RFQ for any costs incurred in preparing a quote. Prior to the preparation of your quote, please read all instructions contained herein. A Contractor's quote shall be clearly stated, complete and provide a straightforward, concise delineation if its capabilities and services to satisfy this RFP. The FBI requires a Contractor to provide all personnel, supplies, equipment, tools, materials, supervision, transportation, and other items and services necessary to perform routine inspections, testing, maintenance, repairs, reporting, and annual fire alarm system operational testing and inspection in accordance with all National Fire Protection Association (NFPA) Codes and Standards, including, but not limited to, NFPA 72 - National Fire Alarm and Signaling Code and NFPA 13 - Installation of Automatic Fire Sprinkler Systems. This intent of this requirement is for a campus wide Fire Alarm Systems inspection/testing, maintenance, repair, and emergency services contract at the FBI's Criminal Justice Information Services (CJIS) Division located at 1000 Custer Hollow Road, Clarksburg, WV 26306. The campus consists of multiple buildings that require fire systems inspection/testing, maintenance, repair, and emergency services for two different fire alarm systems makes/models and components. The FBI's CJIS Division is a secured facility, operational 24/7, with strict requirements for access and movement within buildings of both persons and vehicles. A background investigation will be conducted on all contractor personnel prior to granting access to the site. The FBI requires a Contractor be available to perform emergency repairs of fire alarm systems. The contractor shall respond to all service calls or emergency calls. Upon receiving an emergency call, the contractor shall respond within 30 minutes call back time and shall be on site within a four (4) hour response. This service shall be a seven days a week, 24 hour a day requirement. The two systems which serve the CJIS campus are as follows: (1) Notifier Onyx type and (2) Simplex Grinnell 4100 ES type Fire Alarm System. Notifier Onyx type Fire Alarm System serves the preponderance of the CJIS Division campus and was upgraded in 2015 to the most current version. The complete system consist of the following devices and components: System Component Quantity Initiating Devices: Smoke detectors, heat detectors, pull stations, duct detectors, water flow monitors and control, and monitoring relays 2,597 Human Machine Interface Workstations 4 Alarm Printer 1 Independent Network Annunciators 2 Fire Alarm Control Panels 16 The Notifier Onyx type system interfaces with and controls certain functions of the Siemens Building Management System, six Montgomery/Kone elevators, and one Patterson type electrically driven fire pump. The Simplex Grinnell 4100 ES Fire Alarm System acceptance and annual testing was completed on May 26, 2015. Since acceptance testing the system has been operating normally. And is currently providing fire detection, initiating, monitoring, and annunciation functions. The complete system consists of the following devices: System Component Quantity Initiating Devices: smoke detectors, heat detectors, duct detectors, water flow monitors, pull stations, fire pump, and associated controls 1,004 Annunciation Panels 18 Human Machine Interface Tru Sight workstations 2 The Simplex Fire Alarm System interfaces with the Simplex Grinnell Fire Sprinkler System, the Honeywell Building Management System, Thyssen Krupp Elevator system, Notifier Fire Alarm System, and Patterson electrically driven fire pump. All Contractor Technicians performing repairs or programming on the respective Fire Alarm Systems shall be possess a valid and current National Institute for Certification in Engineering Technologies (NICET) Level III Fire Alarm Technician Certification. See attached notice and referenced attachments for further details.
Award Overview
Award Number
DJF-16-1200-K-0009388
Award Amount (SAM.gov award notice)
$161.0K
Award Date
Sep 30, 2016
Awardee
Awardee UEI
XD3ALW3H84K6
Original Solicitation
Notice ID: 9e2ba503ddbf2e787ffde8afb16ea67e
Posted Date: Oct 5, 2016
Original Response Deadline: Not specified
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
No documents available.
Lifecycle
Solicitation:
FCU-16-0001902- Market Research
- Combined Synopsis
- Awarded
This opportunity has been awarded.
- Market ResearchMay 9, 2016
Fire Alarm Systems Maintenance and Repair
- 3×Combined SynopsisJul 5, 2016
Fire Alarm System Testing, Inspection and Repair
- AwardedCurrentOct 5, 2016
Fire Alarm System Testing, Inspection and Repair
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
FCU-16-0001902
Archive Date
Jan 1, 2022