Z2DA--Replace Dual Duct Boxes on Second Floor - 539-21-201

Archived on July 16, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
1:00 PM EDT
Posted
June 5, 2026
Notice type
Solicitation
NAICS
238220: Plumbing, Heating, and Air-Conditioning Contractors
Agency
Department of Veterans Affairs

Notice details

Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Place of performance
Cincinnati VAMC, Cincinnati, Ohio, 45220
PSC
Z2DA: REPAIR OR ALTERATION OF HOSPITALS AND INFIRMARIES
Last updated
Oct 30, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25026B0042
Notice ID
ffad897dbe654dc3ad38419120845d10

Description

REPLACE DUAL DUCT BOXES ON THE SECOND FLOOR FOR THE VETERANS AFFAIRS MEDICAL CENTER (VAMC) CINCINNATI, OH PROJECT NUMBER: 539-21-201 QUESTIONS AND ANSWERS (RFIs) TO REQUEST FOR INVITATION FOR BID (IFB) NUMBER: 36C25026B0042 QUESTIONS AND ANSWERS : RFI #1 Question: spec 01 00 00 lay down and dumpster area: Where will the laydown and dumpsters area be located? Answer: There is no guarantee of laydown space, contractors shall plan accordingly to support their material. Yes, power is available. Dumpster location will be coordinated with COR. RFI #2 Question: Parking: How many parking spaces will be provided? Answer: Per specification 010000 section: 1.5F2. There will be no parking by any contractors on the VA campus RFI #3 Question: spec 01 35 26 SSHO: Can the superintendent be dual-hatted and fulfill the role of SSHO? Answer: Yes, the superintendent and SSHO can perform both roles RFI #4 Question: spec 02 83 33.13 LBP: Can the government please identify the location and quantities of LBP (lead-based paint) remediation? Answer: The samples tested pertained to painted plaster (white) walls. The analytical results indicated that the white-painted plaster walls contain 480 parts per million (ppm) of lead. If white painted plaster walls are Impacted by the project, contractors should be aware and take the appropriate precautions to comply with OSHA regulations and VA project specifications see lead paint report attached. RFI #5 Question: Procore software: Will the government accept the use of Procore construction management software? Answer: Yes. RFI #6 Question: Life safety drawings: Can the government please provide life safety drawing showing existing smoke and fire walls within the project boundaries? Answer: Existing smoke and fire walls are shown on the drawings. No changes in the safety plan see attached life safety plan. RFI #7 Question: spec 02 82 11 asbestos abatement 1.1.2 extent of work: Is all the ACM removal associated with the mechanical demo? I.E. no abatement is expected to remove mastic etc. on duct, pipe boxes that are not shown for removal. Answer: Yes, the abatement scope is associated with the mechanical demo- see mechanical drawings - see attachment. RFI #8 Question: spec 02 82 11 asbestos abatement 1.1.2 extent of work material locations table: Where is Corridor A-2-15 located? Answer: Contractor to bid quantities for removal. Corridor is C*2*3. Also, corridor A-2-15 is to the north. RFI #9 Question: spec 02 82 11 3.2 removal of ACM/phasing: As the specs call for critical barriers, an attached 3-stage decontamination unit, drop cloths beneath the work, and negative pressure requirements of this specification for any level of abatement. Would the Government allow the phasing for the abatement to include "owning" both sides of the corridors (closed to traffic) for the abatement in the corridors? Answer: All work within corridors shall occur during weekends, between 8PM Friday and 6AM Monday. The corridors shall be opened for normal operations outside of these hours. It is permissible to own both sides (closing traffic) during weekend work. Coordinate with COR. RFI #10 Question: Drawing 1-A001 detail 16 and note 2: 1) Note 2 calls for new wall covering. Does the VA have attic stock to match? If not, can we paint, or please provide the wallpaper manufacturer series and color? 2) detail 16 labels room as C242 is this mislabeled and should be A242? Answer: Paint is an acceptable finish coordinate with COR to match attic stock; the contractor is to provide a level 5 finish from corner to corner. Detail 16 label is mislabeled and should be A242.

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Ronald T Heidemann
Contracting Officer

Documents

Files (19)

  • Atch RFI 7 ACM SURVEY REPORT.pdf

    1.3 MBAdded in Solicitation version 4Posted
    Download
  • Atch RFI 6 life safety plan.pdf

    1.1 MBAdded in Solicitation version 4Posted
    Download
  • Atch RFI 4 Lead Paint Report.pdf

    289 KBAdded in Solicitation version 4Posted
    Download
  • 36C25026B0042 0002.docx

    27 KBAdded in Solicitation version 4Posted
    Download
  • 36C25026B0042_1.pdf

    947 KBAdded in Solicitation version 4Posted
    Download
  • 36C25026B0042 0001.docx

    26 KBAdded in Solicitation version 4Posted
    Download
  • Attachment 12 - Tridium Niagara Redacted.pdf

    262 KBAdded in Solicitation version 2Posted
    Download
  • Attachment 11 -Honeywell Siemens JCI Redacted.pdf

    343 KBAdded in Solicitation version 2Posted
    Download
  • Attachment 10 - FX Controls Redacted.pdf

    270 KBAdded in Solicitation version 2Posted
    Download
  • Attachment 9 - PCRA.pdf

    378 KBAdded in Solicitation version 2Posted
    Download
  • Attachment 8 - ICRA.pdf

    1.7 MBAdded in Solicitation version 2Posted
    Download
  • Attachment 7 - Request for Information.docx

    17 KBAdded in Solicitation version 2Posted
    Download
  • Attachment 6 - EMR Form.docx

    18 KBAdded in Solicitation version 2Posted
    Download
  • Attachment 5 - VAAR 852.219-75.docx

    30 KBAdded in Solicitation version 2Posted
    Download
  • Attachment 4 - Drawings.pdf

    10 MBAdded in Solicitation version 2Posted
    Download
  • Attachment 3 - Specs.pdf

    4.7 MBAdded in Solicitation version 2Posted
    Download
  • Attachment 2 - VHA Directive 1192.01.pdf

    4.1 MBAdded in Solicitation version 2Posted
    Download
  • Attachment 1 - OH20260082 01022026.pdf

    33 KBAdded in Solicitation version 2Posted
    Download
  • 36C25026B0042_1.docx

    143 KBAdded in Solicitation version 2Posted
    Download

Lifecycle

  1. 1
    Version 1SolicitationArchived

    Z2DA--Replace Dual Duct Boxes on Second Floor - 539-21-201

    Notice 3f08fe33bfdb46fb9cd622063e54a9f8 on SAM.gov

  2. 2
    Version 2SolicitationArchived

    Z2DA--Replace Dual Duct Boxes on Second Floor - 539-21-201

    Notice bf8cdb7195eb498aa0862b315f91496f on SAM.gov

  3. 4
    Version 4SolicitationArchivedCurrent

    Z2DA--Replace Dual Duct Boxes on Second Floor - 539-21-201

    Notice ffad897dbe654dc3ad38419120845d10 on SAM.gov

  4. 5
    Version 5Award Notice

    Type changed from Solicitation to Award Notice

    Z2DA--Replace Dual Duct Boxes on Second Floor - 539-21-201

    Notice 0ee9bdf577464779a2727742fa05b72a on SAM.gov

Other notices for this solicitation

  1. Pre-SolicitationApr 27, 2026

    Z2DA--Replace Dual Duct Boxes on Second Floor - 539-21-201

    Notice b38174d829c14aba82fd8c35737afd9a on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

36C25026B0042

Archive Date

Jul 16, 2026

Office Address

DAYTON, OH, 45428