Notice ID: 861977850de0e777d0667d6b9babc5f7Solicitation
Cooling Tower Replacement
Archived on May 16, 2014. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 11:00 PM UTC+02:00
- Posted
- April 2, 2014
- Notice type
- Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
Notice details
- Place of performance
- Cookeville US Post Office and Courthouse 9E Broad Street Cookeville, TN 38503, Cookeville, 38503
- PSC
- Z: MAINT, REPAIR, ALTER REAL PROPERTY
- Last updated
- Dec 4, 2025
Identifiers
- Solicitation number
- GS-04P-14-EX-C-0050
- Notice ID
- 861977850de0e777d0667d6b9babc5f7
Description
COOLING TOWER REPLACEMENT This project will be a 100% Small Business Set-Aside Competitive. The contract will be Firm Fixed Price. The NAICS code is 238220. Project location is Cookeville US Post Office and Courthouse, 9E Broad Street, Cookeville, TN 38503. The Contractor shall provide material, labor, equipment, and supervision to conduct the following work: Furnish and Install 60 ton cooling tower, dispose of existing tower, placement and balancing of new tower, new pad, modificaton of steel enclosure, tie in insulated piping to feed the new tower, replacement of controls box and controls wiring, connect existing tower drain line to sewer per code: The Contractor should visit the site prior to bidding on this project in order to verify all dimensions and familiarize him/herself with the existing conditions, so that they may obtain a full knowledge of any and all difficulties that may be encountered in execution of the work. A payment bond and insurance are required. The Contracting Officer is Dee Otis Henderson, 404-331-9792. The Project Manager is Johnathan Sitzlar, 865-545-4330. Work shall be performed in accordance with all applicable State and Federal codes, and shall be done by a Specialty Contractor skilled in the trade. All work shall be completed within 60 days after Contractor's receipt of contract award. If conditions prevent completion within the schedule, the Contractor shall request a time extension in writing, giving specific reasons why an extension should be granted. The Construction Magnitude is $25,000 to $100,000. The liquidated damages are $844.37 per day. Contractors will be required to submit with their offer at least 3 similar contracts for past performance. Clearances of Contractor personnel is required before work can be started on the project. Award will be made to the offeror possessing the lowest price. The low offeror must possess a satifactory Past Performance.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
No documents available.
Lifecycle
Solicitation:
GS-04P-14-EX-C-0050- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- 3×Pre-SolicitationMar 4, 2014
Cooling Tower Replacement
- SolicitationCurrentApr 2, 2014
Cooling Tower Replacement
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
GS-04P-14-EX-C-0050
Archive Date
May 16, 2014