GovChime
Notice ID: c4401cb3c13bb088f0fc370f6c507ee9Award NoticeAwarded

REPLACE ROOFS, WAESCHE HALL, USCG ACADEMY, NEW LONDON, CT PROJECT #5753515

Awarded on December 22, 2016. Full description on SAM.gov.

Awarded tounder HSCGG1-17-C-PFA002 (source: SAM.gov award notice)• $654.0K

Overview

Posted
December 29, 2016
Notice type
Award Notice
NAICS
238160: Roofing Contractors
Agency
Department of Homeland SecurityUS COAST GUARD

Notice details

Office
CEU PROVIDENCE(000G1)
Place of performance
United States Coast Guard Academy Waesche Hall 15 Mohegan Avenue, New London, 06320
PSC
Z: MAINT, REPAIR, ALTER REAL PROPERTY
Last updated
Dec 5, 2025
Award date
Dec 22, 2016
Award amount (SAM.gov award notice)
$654.0K

Identifiers

Solicitation number
HSCGG1-17-B-PFA002
Notice ID
c4401cb3c13bb088f0fc370f6c507ee9
Award number (PIID)
HSCGG1-17-C-PFA002

Description

HSCGG1-17-B-PFA002 ISSUE DATE: 4 OCTOBER 2016 Contractor shall provide all personnel, equipment, tools, materials, supervision, and other items and services necessary to perform a complete roof replacement of the three (3) low slope roof areas on Waesche Hall at the U.S. Coast Guard Academy. The project includes removal and replacement of all low slope roof membranes, insulation, and flashing down to the structural deck. Protect existing building components that are to remain from damage. Provide temporary barriers at entrances below the work areas as required for safety. Extent of any patching and repair of concrete roof decks will be determined by inspection after deck is exposed and will be addressed by change order at that time. General Requirements: All work shall be done by licensed contractors and shall comply with current codes. Existing fire alarm and mass notification system antennas mounted to building are active and must remain in service during the roof replacement project. Asbestos is assumed to be present within existing roof mastic and caulking in the construction area per the age of the building. Follow all asbestos safety precautions and regulations. Asbestos abatement shall be performed by a licensed asbestos abatement contractor. Lead abatement is not part of the project. Lead based paint is assumed to be present within all existing painted surfaces in the construction area per the age of the building. Follow all lead safety precautions and regulations when cutting, sanding, etc. any painted surfaces containing lead. Demolition and Abatement: Remove, salvage, and recycle metal copings, flashings, miscellaneous metal, etc. recycled as noted in documents and provide credit to the Government. Completely remove existing modified bitumen roof membrane and insulation down to the structural deck and replace with a new roofing system. The existing modified bitumen roof membrane and silver coating do not contain asbestos; however the black tar on the metal counter flashing does contain asbestos and shall be removed and properly disposed of by a licensed asbestos abatement contractor. Remove and recycle or properly dispose of all construction debris. Installation: Patch and repair structural decks as required for installation of new roof system. Provide and install membrane roof systems, including fully adhered vapor barrier, polyisocyanurate insulation, tapered insulation board, " cover board, 60 mil EPDM membrane, flashing, etc. Provide new EPDM flashing at walls, equipment curbs, pipe penetrations, etc., wood blocking, flashing, and metal edge flashing and all required accessories for a complete and watertight roof system. Provide and install new lead coated copper flashing, fascia, edge flashing, drain bowls, and leaders as noted on drawings. Remove existing sealant at joint between the masonry wall and copper counter flashing. Remove, salvage to the maximum extent practical, and replace several courses of brick above flashing, replace wall and counter flashing with 20 oz lead coated copper flashing, add weeps to joint and point joints with lime mortar. Remove and replace existing roof drains and dome strainers, 4" or 5"cast iron pipe and fittings connect to existing roof leaders, seven (7) locations. Remove, salvage, and reinstall existing steel pipe enclosures in library as required to replace damaged drain pipe. Provide additional roof drain and dome strainer in lobby roof as shown on drawings, and connect to existing roof leader with new 4" cast iron piping and fittings. Remove, salvage, and reinstall existing acoustic ceiling tile in good condition and replace damaged acoustic ceiling tiles in areas of new roof drain installation and existing roof drain replacement. Remove damaged acoustic ceiling tile in work areas and provide new acoustic ceiling tiles to match existing. Performance Period: The Period of Performance for the project is 35 weeks with 12 weeks allowed for work on site. Anticipated mobilization in May 2017 after graduation; on site work estimated at 12 weeks. Project closeout and complete by September 2017. No work shall be performed on base, Commencement week May 15 thru 19, 2017, R-day Monday June 28, 2017, Friday of Parents' Weekend TBD, Friday of Homecoming Weekend TBD, and federal holidays.

Full description on SAM.gov

Award Overview

Award Number

HSCGG1-17-C-PFA002

Award Amount (SAM.gov award notice)

$654.0K

Award Date

Dec 22, 2016

Awardee

Awardee UEI

KMAGS9VNCKG3

Original Solicitation

Notice ID: c4401cb3c13bb088f0fc370f6c507ee9

Posted Date: Dec 29, 2016

Original Response Deadline: Not specified

Contacts

Contracting Officer

Primary Contact

Teresa L. Lamphere
Contracting Officer
Fax: 401-736-1704

Secondary Contact

Jean M Bretz
SR FIELD CONTRACTING OFFICE
Fax: (401)736-1704

Documents

No documents available.

Lifecycle

Solicitation:HSCGG1-17-B-PFA002
  1. Pre-Solicitation
  2. Solicitation
  3. Awarded

This opportunity has been awarded.

  1. 4×
    Pre-SolicitationSep 15, 2016

    REPLACE ROOFS, WAESCHE HALL, USCG ACADEMY, NEW LONDON, CT PROJECT #5753515

    Notice 1371579068d7e4f0bbb4de5eee37d296 on SAM.gov

  2. SolicitationNov 9, 2016

    REPLACE ROOFS, WAESCHE HALL, USCG ACADEMY, NEW LONDON, CT PROJECT #5753515

    Notice 0300f50f20415de78ee3f8daf97e3c01 on SAM.gov

  3. AwardedCurrentDec 29, 2016

    REPLACE ROOFS, WAESCHE HALL, USCG ACADEMY, NEW LONDON, CT PROJECT #5753515

    Notice c4401cb3c13bb088f0fc370f6c507ee9 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
This is a SOURCES SOUGHT NOTICE to identify firms capable of performing Replace Roofs, U.S. Coast Guard Station Building Kenosha, Kenosha, WI 53140. Major work items include but are not limited to: Remove existing asphalt roof down to existing roof sheathing and provide new asphalt roof system at Station Building’s main roof area (approximately 32-foot by 46-foot), addition roof area (approximately 46-foot by 46-foot), and existing porch roof area (approximately 10-foot by 30-foot) and Boat House roof replacement, approximately 45-foot by 60-foot plan square footage; Mobilization, demobilization and clean up; Supervision, materials, equipment, transportation, labor and all other incidentals necessary to complete the work. The procurement estimate is between $25K and $100K. The NAICS for this project is 238160 with a Small Business Size Standard of $19.0M. At a minimum, the prime contractor will be required to perform 25 percent of the cost of the contract with its own employees (not including cost of materials). Vendors interested in performing this requirement are invited to provide the following information to USCG Base Cleveland no later than April 01, 2026. The information may be submitted via email to the Contracting Officer at timothy.g.arnold@uscg.mil . Responses shall include the following information: Reference number70Z03026BCLEV0036, company name, address, SAM Unique Entity ID, point of contact, phone number, email address; and, the following information (items (a) through (f)). Your response shall include the following information and be in sufficient detail for a determination to be made regarding the type of set-aside for this procurement: A positive statement of your intent to submit a bid on this solicitation as a prime contractor. A statement identifying your certified small business size status (Small, HUBZone, VOSB, SDVOSB, disadvantaged, women-owned). Evidence of experience in work similar in type and scope, to include contract numbers, project titles, dates work performed, dollar amounts, points of contact and telephone numbers. Statement that your firm has/has not previously performed work under this NAICS as a prime contractor. Provide evidence of bonding capability to the maximum magnitude on the project to include both single and aggregate totals. State the number and occupations of employees in your firm. NO TELEPHONE OR WRITTEN REQUESTS FOR SOLICITATIONS OR POSTING STATUS. When available, and if competed, the resultant pre-solicitation notice and solicitation will be posted at this website. The type of set-aside will be stated in these postings. This notice is for information and planning purposes only and is not to be construed as a commitment by the Government, nor will the Government pay for information solicited. No basis for claim against the Government shall arise as a result from a response to this Sources Sought or Government use of any information provided. The Government reserves the right to consider a small business, 8(a), or any other set-aside arrangement as deemed appropriate for this procurement.
-Market Research04/01/2026
IFB NO. N4008426B1005 / Contract NO. N40084-27-D-1005, IDIQ Contract to Repair and Replace Roof Systems at Commander Fleet Activities Yokosuka (CFAY) and Naval Air Facility Atsugi (NAFA), Japan
-AwardedOpen
The Princeton Plasmas Physics Laboratory is seeking a qualified contractor to replace roofing on two existing roofs. The (C40 RF Building & C41 CS Building) which are past their useful life requiring costly maintenance to upkeep. Severe water infiltration occurs regularly at failing joints, punctures, and flashing. Portions of existing metal coping have pulled away during storm events causing large sections of membrane to separate from the substrate. A catastrophic failure to one of these roofs would negatively impact the ability to conduct the top priority experimental operations in the Laboratory. The Subcontractor shall provide all materials, labor, supervision, equipment, and expertise required to replace the noted roofs and specified components per the associated contractdesign documents. Construction scope includes the following: Remove and replace existing built-up roofs at PPPL. Buildings include: a. C40 – RF Building b. C41 – CS Building All work shall be perfomed IAW SOW titled: C40 & C41 RF ROOF REPLACEMENT CONSTRUCTION dated 28 Aug 2026 The project drawing have not been posted. The drawings will be released to offerors (on an as requested basis) when we receive the following information and documents (1) An e-mail confirmation of your intent to participate in the site visit/pre-bid meeting scheduled for 11/17/26 (2) A signed solicitation acknowledgement form (3) Identification of your lead proposal manager for this solictation via e-mail (4) A written request for project drawings (see attached form) The link to complete your Princeton supplier registration is referenced below:: https://finance.princeton.edu/buying-paying/suppliers/becoming-princeton-supplier **To be eligible to participate in this solicitation your firm must submit the acknowlegment form to us NLT 4:00 PM on 9 Nov 2026
-Combined Synopsis12/10/2026
-AwardedOpen
Nez Perce Clearwater National Forest Fenn Ranger Station cedar shake roof replacement. The solicitation is CANCELLED pending revisions of specifications and statement of work.
-Combined Synopsis11/19/2026

Additional Details

Solicitation Number

HSCGG1-17-B-PFA002

Archive Date

Jan 6, 2017