GovChime
Notice ID: cfddd0a7950c4f0b906cc57ab6303709JustificationAwarded

Beckman Coulter Hematology Analyzers and Reagents for Naval Hospitals Yokosuka and Okinawa

Awarded on May 3, 2023. Full description on SAM.gov.

Overview

Posted
May 9, 2023
Notice type
Justification
NAICS
334516: Analytical Laboratory Instrument Manufacturing
Agency
Department of WarDEFENSE HEALTH AGENCY (DHA)

Notice details

Office
DEFENSE HEALTH AGENCY
Place of performance
YOKOSUKA and OKINAWA
PSC
6550: IN VITRO DIAGNOSTIC SUBSTANCES, REAGENTS, TEST KITS AND SETS
Last updated
Dec 4, 2025
Award date
May 3, 2023
Award amount (SAM.gov award notice)
Not specified

Identifiers

Solicitation number
HT941022N0010
Notice ID
cfddd0a7950c4f0b906cc57ab6303709

Description

Hematology analyzers are required to attain the standard for production for Naval Hospitals Okinawa and Yokosuka Japan and Branch Health Clinics located in Atsugi, Sadebo, and Iwakuni, Japan and Diego Garcia, United Kingdom. Hematology benches are workstations used to conduct Complete Blood Counts and other hematology testing methods. Without in-house analyzers, the blood samples would have to be shipped to laboratories in Japan or the United States. Blood samples cannot be frozen for transport and must be analyzed within 48 hours to ensure the integrity of the sample and the test results. Samples from remote locations like Diego Garcia will take approximately 1 week to ship to laboratories in Japan resulting in a 2-week turnaround for critical and potentially life-saving test results and diagnosis. One potentially viable option is to send samples to local laboratories in Japan; however, utilization of these laboratories presents a greater risk of clerical errors due to language barriers in addition to additional turnaround time, the risk of reliable transport of samples between sites, and sample deterioration which can lead to adverse patient outcomes in emergency situations. The nine (9) hematology analyzers, to be delivered, installed, and validated no later than 1 January 2023 meeting the following minimum requirements: Must have a Laboratory Information System (LIS) and ethernet connection Must have date storage: 30,000 patient results including graphics, flags, codes and messages Must have 12 control files each with a maximum of 150 runs Must perform roughly 1,000 test per month within 48 hours of blood draw to include 17 uL of venous or micro-collected whole blood and 20 uL of hole blood for pre-diluted analysis Must provide results for the following Complete Blood Count parameters: white blood cell, red blood cell, hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration red cell distribution width-standard deviation, platelet, mean platelet volume, reticulocytes, absolute reticulocytes, mean reticulocyte volume, immature reticulocyte fraction Must provide the following differentials: neutrophils, lymphocytes, monocytes, eosinophils, basophils, monocyte volume width distribution, nucleated red blood cell, absolute neutrophils, absolute lymphocytes, absolute monocytes, absolute eosinophils, absolute basophils, absolute nucleated red blood cell Must perform the following body fluids (CSF, serous and synovial): total nucleated cell count, red blood cell, @BFM%, @BFP% Must be able to use USB printer Must have touch screen display and handheld barcode scanner Local maintenance and repair support for the 4 geographic locations within 12 hours of notification, including weekends and holidays. Manufacturer must offer on-site training, in English, for two (2) technicians in Japan and a separate training for the Branch Clinic located in Diego Garcia in conjunction with installation Due to the configuration of the laboratories, the following size and electrical limitations must be met: Analyzer 1 (Diego Garcia) (Qty 2): H: 406mm, W: 270mm, D: 430mm; Weight: 25.1lbs Electrical Power Supply: VAC 100-240, Hz 50-60, three-wire AC outlet, Single Phase Analyzer 2 (Qty 5): H: 82.42cm, W: 75.57cm, D: 82.80cm; Weight: 560 lbs Electrical Power Supply: VAC 90-264, Hz 48-63, three-wire AC outlet, Single Phase Critical Values Feature: Enables onscreen and printed notification of critical hematology results to enable easy identification and accelerated reporting of critical values. User-defined critical values and customized notification text add flexibility needed to support the differences in notification policies from one facility to another.

Full description on SAM.gov

Award Overview

Award Number

HT941023P0001

Award Amount (SAM.gov award notice)

Not specified

Award Date

May 3, 2023

Awardee

Not specified

Original Solicitation

Notice ID: cfddd0a7950c4f0b906cc57ab6303709

Posted Date: May 9, 2023

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

4
  • HT941024P0273
    BECKMAN COULTER K.K.
    Department of DefenseNAICS 334516
    $103.0KSigned Apr 20, 2026
  • HT941024P0273
    BECKMAN COULTER K.K.
    Department of DefenseNAICS 334516
    $103.0KSigned Feb 26, 2026
  • HT941024P0273
    BECKMAN COULTER K.K.
    Department of DefenseNAICS 334516
    $15.5KSigned Aug 21, 2025
  • HT941024P0273
    BECKMAN COULTER K.K.
    Department of DefenseNAICS 334516
    $159.9KSigned Jan 13, 2025

Contacts

Documents

No documents available.

Lifecycle

Solicitation:HT941022N0010
  1. Market Research
  2. Awarded

This opportunity has been awarded.

  1. Market ResearchSep 8, 2022

    Hematology Analyzers Naval Hospital Yokosuka

    Notice 174cdb6d806445e0a74cec9a9ee6a68b on SAM.gov

  2. Sole Source / J&ACurrentMay 9, 2023

    Beckman Coulter Hematology Analyzers and Reagents for Naval Hospitals Yokosuka and Okinawa

    Notice cfddd0a7950c4f0b906cc57ab6303709 on SAM.gov

Similar Opportunities

Title
Phase
Deadline

Additional Details

Solicitation Number

HT941022N0010

Archive Date

Not specified

Place of Performance Country

JPN

Office Address

FALLS CHURCH, VA, 22042