GovChime
Notice ID: ddcd7d9581d0438db3cb116d335f0aa9Sources Sought

Fiber Dial Room Refurbishment

Active, responses due . Full description on SAM.gov.

Overview

Response deadline
11:59 PM MST
Posted
March 18, 2026
Notice type
Sources Sought
NAICS
238210: Electrical Contractors and Other Wiring Installation Contractors
Agency
Department of Energy

Notice details

Office
BATTELLE ENERGY ALLIANCE–DOE CNTR
Place of performance
Idaho Falls, Idaho, 83415
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
INL-26-029
Notice ID
ddcd7d9581d0438db3cb116d335f0aa9

Description

INTRODUCTION

Battelle Energy Alliance, LLC (BEA) Management & Operating Contractor of the U.S. Department of Energy (DOE) owned Idaho National Laboratory (INL), is seeking an Expression of Interest (EOI) from qualified vendors to provide refurbishment services for the Fiber Dial Room and implement point-to-point fiber connectivity upgrades. This initiative supports BEA’s commitment to maintaining robust and reliable communications infrastructure across INL facilities.

BACKGROUND

The Fiber Dial Room requires refurbishment and modernization to support enhanced fiber optic connectivity and point-to-point communication capabilities. The scope of work may include the following:

  • Remove legacy abandoned communication cables around the plant.
  • Refurbishment of several Fiber Dial Rooms around TAN, including structural and environmental improvements and replacement of hardware.
  • Installation and testing of new fiber and communications.
  • Installation and configuration of point-to-point fiber connections.
  • Integration with existing network infrastructure and systems.
  • Compliance with DOE cybersecurity, safety, and operational standards.
  • Testing and documentation to ensure full functionality and reliability.

INL is a U.S. Department of Energy (DOE) national laboratory dedicated to nuclear energy, national security, and clean energy innovation. INL is operated under a management and operating contract with the Department of Energy and as such, the Davis-Bacon Act applies for contracts in excess of $2,000 for the construction, alteration, or repair (including painting and decorating) of buildings or works at INL. Construction work at the laboratory Site covered under the Davis-Bacon Act is additionally subject to the INL Site Stabilization Agreement (SSA). These Site areas include all areas within the 890-square mile boundary, including the Material and Fuels Complex, Central Facilities Area, Advanced Test Reactor, Radioactive Waste Management Complex, and Specific Manufacturing Capability. The agreement is between signatory contractors and labor unions performing such work. Information regarding the INL Site Stabilization Agreement is available from the Site Labor Coordinator at (208) 524-4404 or at lance@sitelabor.org. Construction work performed at Idaho Falls facilities is not subject to these agreements.

PROCESS

This EOI is the first step in identifying interested and qualified vendors. Responses may be used to inform the development of a formal solicitation list. Selected vendors may be invited to participate in a Request for Proposal (RFP) process for award consideration.

SUBMITTAL REQUIREMENTS

Interested vendors should submit an Expression of Interest that includes the following:

  • Company name and point of contact
  • Description of relevant fiber installation and refurbishment capabilities and experience
  • NAICS codes and business size classification
  • Any existing DOE or federal contracting experience (if applicable)

Deadline for submission: December 11, 2026
Submit to: Chase.Egbert@inl.gov

Only select respondents, as determined by BEA, will receive an invitation to participate in the anticipated RFP solicitation.

PROPRIETARY INFORMATION

Because information received in response to this EOI may be business sensitive or proprietary to the responding party, respondents must mark information in their responses accordingly.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Sep 22, 2025

NAICS

238210

Agency

Department of Energy

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Documents

Files (1)

  • Fiber Dial Room Refurbishment EOI.pdf

    202 KBAdded in Sources Sought version 4Posted
    Download

Lifecycle

  1. 1
    Version 1Sources Sought

    Fiber Dial Room Refurbishment

    Notice 5c834987211d4875824e32cdf290f2ca on SAM.gov

  2. 2
    Version 2Sources Sought

    Fiber Dial Room Refurbishment

    Notice 3cec5e8a260a443190a77ff844fe48af on SAM.gov

  3. 3
    Version 3Sources Sought

    Fiber Dial Room Refurbishment

    Notice f18b48de8e084122ba2896b09242d0ec on SAM.gov

  4. 4
    Version 4Sources SoughtCurrent

    Fiber Dial Room Refurbishment

    Notice ddcd7d9581d0438db3cb116d335f0aa9 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Forest Service Fernan Ranger Station lift station electrical repairs in accordance with the statement of work. Solicitation number 1240LU26Q0125 is issued as a request for quotation (RFQ). The magnitude of the project is under $25,000.
-Combined Synopsis11/19/2026
Pre-Solicitation Notice This is a special notice prepared in accordance with the Revolutionary FAR Overhaul (RFO) Federal Acquisition Regulation (FAR) 5.1 “Pre-solicitation Notice” for Commercial Simplified Acquisition in accordance with FAR 12.201-1(c)(2). In accordance with Revolutionary FAR Overhaul FAR 12.201-1(c)(2), the Government may solicit quotations directly from suppliers for this acquisition at or below the simplified acquisition threshold. The USDA-Forest Service intends to award a firm fixed price (FFP) contract using Simplified Acquisition Procedures that meets the specifications outlined below. This solicitation is a 100% Small Business Set-Aside. Quotes will be requested under reference 1240LU27Q0008. 1. Notice Title and Type Pre-Solicitation Notice 2. Agency and Contracting Office Issuing Office: USDA Forest Service Intermountain 9 Office Address: 415 South Front Street, Townsend MT, 59644 Point of Contact: Alisha Knaub, alisha.knaub@usda.gov 3. Description of Requirement The electrical system in the Fernan RS snowmobile shed needs to be restored and upgraded in order to supply general electric supply and support an e-bike battery charging station, power light fixtures, and provide electric service for any tools and appliances needed for maintaining snowmobiles, ATVs, and e-bikes. The current source of power is unserviceable and will be bypassed with a new conduit stemming from the main distribution panel located approximately 130ft from the building with a new 4-circuit breaker box which will supply four new 120 volt, 20-amp outlets and the light fixtures currently installed. 4. NAICS Code The applicable North American Industry Classification Standard Code is 238210 - Electrical Contractors and Other Wiring Installation Contractors. The small business size standard is $19M. 5. Set-Aside Information This acquisition is a Total Small Business Set-Aside. 6. Tentative Dates RFQ Release to interested contractors: 11/10/2026 Anticipated Award Date: 11/30/2026 7. Project Location: 2502 E Sherman Ave Coeur d'Alene, ID 83814 8. Period of Performance: Project is expected to begin approximately 12/01/2026 and completion date will be approximately 1/15/2027. 9. Price Range: Less than $25,000. 10. Contact Information Send your email notifying interest in project to: Forest Service, Property and Procurement Services, Intermountain Zone, CSA #9 Attn: Alisha Knaub E-mail: alisha.knaub@usda.gov Please include the name and number (Fernan RS Snowmobile Shed Electrical Project, 1240LU27Q0008) as the subject line of the email. Also include your companies UEI number in the email.
-Pre-Solicitation11/09/2026
Sources Sought Notice Sources Sought Notice Page 6 of 6 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 6 Introduction Network Contracting Office 20 (NCO20), supporting Boise, Idaho VA Medical Center, is seeking potential sources for an upcoming requirement for a Contractor that shall provide services for inspection/testing work on the station electrical distribution system at the Boise, Idaho VA Medical Center (BVAMC) as described below. This notice is a market research tool and has not been set-aside for any small business category, however the notice is issued to determine appropriate set-aside categories. Responses to this notice, in conjunction with other Government market research resources, will be used by the contracting officer to determine the applicable socio-economic set-aside for the procurement. Failure to respond to this notice will not impact consideration of construction services companies (or joint ventures) which otherwise meet set-aside requirements and submit responses to the follow-up public announcement. Once the appropriate set-aside is determined, a separate public announcement requesting offers/proposals will be publicized on Contract Opportunities in accordance with FAR 36.213-2. General Project Description and NAICS 1. Provide all materials, equipment, and labor to complete the following inspection/testing work on the station electrical distribution system. a. Test, inspect, and calibrate all breakers and relays in the 15KV switchgear located in Building 83. Clean all relays before testing including, remove any metal filings from disks and magnets, clean/burnish contacts, and check contact wipe. b. Visually inspect and infrared test the15KV switchgear in Building 83, 41 pad-mount transformers, 10 vault mounted VFI switches, 3 sectionalizes, and the main building distribution panels in the following locations: G14-27, G05-46, G25-67, G02-77, 117-85, 133-88, 122-109, 201-109, 116-110, 115-114, 112-117, 102-120, GRNDS-121, GRNDS-122, 106-123, 200-123, and 127-124. Infrared test each breaker in the main distribution panels as described above. Test the GFI trip rating of each GFI breaker. Test and calibrate all relays in the main distribution panels. c. Obtain an oil sample from each of the 41 pad-mount transformers located throughout the campus grounds. Sample oil for dissolved gases, moisture content, dielectric breakdown voltage, acid, color, visual, specific gravity, and interfacial tension. Use ASTM D1816 to test dielectric breakdown voltage. Check the pressure gage to assure the nitrogen blanket is still intact. Check the oil level in each transformer. Clean any cobwebs and debris from each of the transformers. Check transformers to assure they are level. d. Infrared test and vacuum out 14 automatic transfer switches, 1 in B.46, 1 in B.27, 1 in B.77, 3 in B.67, 1 in B.88, and 7 in B.85. 2. At the conclusion of the above testing, inspections, and calibration, provide a written report to the VA Medical Center outlining the work performed. Include a letter of explanation summarizing the procedures followed and any problems noted while conducting the work. Include in the report the oil analysis for each transformer. Include infrared pictures of any problem areas identified. Indicate all areas of concern with written recommendations on how to maintain the electrical system and how to correct all problems identified. Include a cost estimate for each recommendation. 3. Any work that requires a disruption to the Medical Center power will have to be scheduled in advance. Work which causes a disruption of power to Building 85, will have to be accomplished at other than normal hours, when Surgery is not in operation. 4. The contractor selected to perform this work must perform this type of work on a regular and recurring basis and have done so for a minimum of 5 years. The contractor must have a person on site who is NETA certified and NICET certified, and the company must be NRTL certified per federal OSHA standards. This requirement is being sought under North American Industry Classification System Code 238210 Electrical Contractors and Other Wiring Installation Contractors, size standard is $19 Million dollars. Any interested party who believes they can complete this requirement under these or any other NAICS codes are invited to respond and provide detail as to the NAICS they can complete this project under and a brief description as to the reasoning. Responses will be used to research which code in conjunction with other Government market research resources will be used by the contracting officer to determine the NAICS code under which this project will be procured. Information Sought The Government requests a letter of interest (or similar document) with responses to the following: 1. State your business name (as it appears in SAM.gov), office location where these services will be performed from, SAM UEI number, NAICS Code under which you will perform and socio-economic status of the firm (i.e. verified SDVOSB, WOSB, SB, large business). 2. Provide a brief narrative and list sample projects/references completed on your company s experience providing services similar to those described. 3. What would be the expected make-up of the company s team in terms of socio-economic categories and estimated percentage of work to be completed by your company and each subcontractor? If the procurement is set-aside for any category of small business, generally fifty percent of more of the work would need to be performed by the contractor or a similarly situated subcontractor in terms of percentage of cost. For instance, if set-aside for service-disabled veteran-owned small business (SDVOSB), 50% or more of the contract would need to be performed by verified SDVOSBs no other small business categories would count towards the percentage. If set-aside for small business, 50% of the contract would be required to be performed by small businesses, which would include performance by a verified SDVOSB because they are also a small business. If the procurement is not set-aside and reaches certain dollar thresholds, the Government would negotiate an acceptable subcontracting plan to utilize small business concerns. 4. A brief statement of overall interest in the project and capability of performing the work in conjunction with ongoing projects. 5. Any additional capabilities statements or other documentation that you feel will assist the Government in performing market research and determining the appropriate set-aside. Submission Instructions Interested parties are requested to submit the requested information not later than October 18, 2025 to Alan Perez via email to Alan.Perez@va.gov and Helen Woods at Helen.Woods@va.gov. Please include 531-26-1-0001 Sources Sought Response in the title of the email. The response burden to this notice is expected to be light; lengthy responses are not expected but no maximum page count is assigned. Please keep responses below 7MB or send multiple emails appending to the email subject 1 of n as appropriate. Please contact Alan Perez at the email above with any questions.
-Market Research10/28/2025
AMENDMENT: The purpose of amendment 00001 is to extend the due date to 10/30/2026 at 5:00 PM CST. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotations are being requested and a separate written solicitation will not be issued. Solicitation number ​1232SA27Q0011 is issued as a ​Request for Quotation (RFQ)​ for ​the emergency repair of the NSGC cold storage dehumidifier system. This acquisition ​is​ set-aside for small business concerns. The applicable North American Industry Classification Standard Code is ​238220.​ The small business size standard is $19M.​ All responsible sources may submit a quotation which will be considered by the agency.
-Combined Synopsis10/30/2026
The purpose of this amendment is to remove wording unintentionally added to the Request for Information 36C24827Q0104. Please disregard the highlighted sentence below that is currently in the Description under SCOPE OF WORK . It should not be included. SCOPE OF WORK: The Contractor shall provide all labor, travel, parts, materials, transportation, equipment, tools, training, supplies, management and supervision to perform circuit tracing and documenting electrical circuits within the critical and non-critical areas of Building 1. The Contractor shall furnish all labor, equipment, sanitized, disinfected and labels for containers, supplies, materials, transportation and supervision required to provide pick up, transport, incineration and/or acceptable disposal of biomedical infectious, veterinary, chemotherapy, biological/pathological, sharps waste, and contaminated wastes. Attached is the corrected copy of the Request for information description.
-Market Research11/11/2026

Additional Details

Solicitation Number

INL-26-029

Archive Date

Dec 11, 2026

Office Address