GovChime
Notice ID: 7439e0ff36514caa9ae056fd3cec2341PresolicitationArchived

Replace Siding, Moore Air Base, TX

Archived on September 15, 2025. Full description on SAM.gov.

Overview

Posted
July 11, 2025
Notice type
Presolicitation
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
NAICS
238170: Siding Contractors
Agency
Department of AgricultureANIMAL AND PLANT HEALTH INSPECTION SERVICE

Notice details

Office
MRPBS MINNEAPOLIS MN
Place of performance
Edinburg, 78541
Last updated
Nov 11, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
JR1155376
Notice ID
7439e0ff36514caa9ae056fd3cec2341

Description

USDAs Animal and Plant Health Inspection Service has a construction requirement to remove metal corrugated sheeting from building 6418 at Moore Air Base in Edinburg, Texas, and replace it with Hebel wall panels or equal. Background: Building 6418 at Moore Air Base is a Mexican Fruit Fly Rearing Facility. The Mexican Fruit Fly Program is charged with the eradication of Mexican Fruit Flies from the Lower Rio Grande Valley in Texas and the northern municipalities of Tamaulipas, Mexico. This project will be set aside for service-disabled veteran-owned small business firms only. The NAICS code is 238170 Siding Contractors, with a small business size standard of $19 million. The estimated magnitude of the project is between $500,000 and $1 million. The project will be set aside for small business concerns only. The solicitation will be posted on or about July 23, 2025. It is the responsibility of interested parties to monitor this site for the solicitation and amendments, if any. Questions concerning this synopsis should be directed to Jim Roloff, contracting officer, at james.g.roloff@usda.gov.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

No documents available.

Lifecycle

  1. 4
    Version 4PresolicitationArchivedCurrent

    Replace Siding, Moore Air Base, TX

    Notice 7439e0ff36514caa9ae056fd3cec2341 on SAM.gov

  2. 2
    Version 2SolicitationArchived

    Type changed from Presolicitation to Solicitation

    Replace Siding, Moore Air Base, TX

    Notice ee03a86abc10454e9ba94a7ab5a25927 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
USACE, Pittsburgh District, has an upcoming requirement to replace the siding of the Resource Managers Office at Youghiogheny River Lake. The work described herein shall be performed at the Youghiogheny Resource Managers Office (RMO) building located within the Youghiogheny River Lake project area in Confluence, Pennsylvania. The building currently serves as administrative office space for the U.S. Army Corps of Engineers. The RMO building was constructed in 1986 and is a multi-level, timber-framed structure built into the hillside overlooking the impoundment side of the dam. The exterior walls consist of 2x6 wood stud framing with 6-inch fiberglass batt insulation (R-19, foil-faced). Interior partitions consist of 2x4 wood studs with 1/2-inch gypsum wallboard. The existing exterior wall assembly consists of 1/2-inch asphalt-saturated fibrous sheathing with 5/8-inch cedar-faced T1-11 plywood siding, for a combined nominal thickness of 1-1/8 inches. Exterior trim and fascia consist of various widths of cedar lumber. The building is supported by cast-in-place concrete footings and 12-inch concrete masonry unit (CMU) foundation walls. The rear wall section and balcony framing are supported by 4 feet-0 inches wide by 5 feet-0 inches deep concrete footings, laminated wood columns (8-3/4 inches x 15 feet-0 inches), and laminated wood beams (8-3/4 inches x 15 feet-0 inches).This project consists of the removal and replacement of the existing exterior wall cladding system. The Contractor shall remove and dispose of the existing T1-11 siding and 1/2-inch asphalt-saturated fibrous sheathing in their entirety. The Contractor shall furnish and install a new exterior wall assembly consisting of 1/2-inch APA-rated structural wood sheathing, a continuous weather-resistive barrier (WRB), 3/8-inch nominal preservative-treated wood furring strips, and 5/16-inch fiber cement lap siding in accordance with manufacturer requirements. The new wall assembly is intended to match the existing wall thickness (approximately 1-1/8 inches) to maintain alignment with existing window and door openings. Minor dimensional variation within normal construction tolerances are acceptable and shall not require modification or resetting of existing windows and doors. The Contractor shall not reset, relocate, or otherwise modify existing windows and doors. Furring strips shall be installed vertically over the WRB at a maximum spacing of 16 inches on center and shall be fastened through the sheathing into wall framing members. Fiber cement siding shall be installed horizontally over the furring strips and fastened through the furring and sheathing into wall framing members. Furring strips are intended to provide a drainage and ventilation cavity and shall not be used as the sole fastening substrate for the fiber cement lap siding. The Contractor shall ensure that all fiber cement lap siding edges are supported by framing members or approved blocking in accordance with manufacturer requirements. The Contractor shall furnish and install all required trim at windows, doors, corners, and transitions. Trim material shall be fiber cement. The cedar hand railing on the balconys is to be new capped PVC or capped composite decking of matching color to fiber cement board siding. The Contractor shall provide complete flashing at all required locations, including but not limited to head flashing at windows and doors, Z-flashing at horizontal joints and transitions, and kick-out flashing at roof-to-wall intersections. All flashing shall be integrated with the WRB in a shingle-lap manner to maintain a continuous drainage plane. The work shall be completed within 180 after written Notice to Proceed. The acquisition will be procured as 100% Set-Aside for Small Business. The resulting award will be for one (1) Firm-Fixed-Price (FFP) Contract. All responsible Quoters are encouraged to participate. The Request for Quotes (RFQ) will be issued on or about 19 August 2026, online through Procurement Integrated Enterprise Environment (PIEE) which posts the opportunity to SAM.gov; therefore, requests for hardcopies of the solicitation will not be honored. The North American Industrial Classification System (NAICS) Code for this acquisition is 238170 - Siding Contractors. The Small Business Size Standard for this NAICS Code is $19,000,000.00. In order to submit a Bid on this project, your company must- Be registered in System for Award Management (SAM) and maintain an active registration status. Be registered in the Procurement Integrated Enterprise Environment (PIEE) for the Solicitation Module with the PROPOSAL MANAGER Manger role. System for Award Management (SAM) Registration Registering in SAM.gov includes both entity validation and entity registration. To register in SAM: Navigate to SAM.gov Select Sign-In (top right) Select Create an Account then Follow the Instructions. After Account is Set-up, Select Sign In. Under the Entity Management widget, Select “Get Started” button. Select Register Entity. As part of entity registration, a Unique Entity ID will be assigned. For Additional Information on SAM To Register Your Entity (company), please visit https:/www.fsd.gov/gsafsd_sp?id=gsa_index . Here you will find the following, Get Started with Your Registration Check Registration Status – ACTIVE, INACTIVE, PENDING Update Your Registration Become an Entity Administrator Validate Your Entity *Access User Guides *By selecting this option, you can obtain a Quick Start Guide for Contract Registrations. Also, here you will find in addition to the User Guides - FAQs, Videos, and Definitions. PLEASE NOTE It is mandatory that all companies be registered in SAM in order to receive federal contracts. There is no charge to register or maintain your company (entity) registration. Login.gov manages usernames and passwords for SAM.gov. *Important* Registration Information Registration can take at least ten (10) business days to be active in SAM.gov. Registration must be in active status upon offer submission and remain active during award period. Registration must be renewed every 365 days to remain active. The Federal Service Desk (FSD) for SAM questions, may be contacted. Phone Number: 866-606-8220 Hours of Operation: Monday-Friday 8 a.m. to 8 p.m. ET Procurement Integrated Enterprise Environment (PIEE) Solicitation Module Registration To register for PIEE follow the below instructions. Register in PIEE: a. Navigate to https://piee.eb.mil/ b. Select Register [top right] c. Select Vendor d. Create a User ID and Password and follow the prompts [next] e. Create Security Questions [next] f. Complete your User Profile Information [next] g. Complete your Supervisor or Approving Official Information [next] h. Complete Roles i. Step 1. Select SOL-Solicitation ii. Step 2. Select Proposal Manager iii. Step 3. Click Add Roles iv. Step 4. Fill in your Location Code (CAGE Code) [next] i. Provide a justification for your registration [next] j. Follow the remaining prompts to submit your registration The Procurement Integrated Enterprise Environment (PIEE) help desk may be reached by calling telephone number 866-618-5988 for assistance.
53%
Pre-Solicitation08/19/2026
TX - CADDO LAKE NATIONAL WILDLIFE REFUGE (NWR) - VISITOR CENTER SIDING REPAIR, KARNACK, TX DESCRIPTION: The U.S. Fish and Wildlife Service has a construction project for work that requires removal of the existing damaged siding on the visitor center trailer (back) and the end of an auxiliary trailer (see attached photos). Both locations to be replaced with new color matched, J-channel, underpinning, trim and siding (approximately 600 Square Feet). Please read the entire Request for Quotation (RFQ) and all attachments prior to submitting quote. Solicitation number 140FF027Q0012 is being issued as an RFQ. This solicitation is for a Firm Fixed Price contract. This is a 100% Total Small Business Set-Aside solicitation with an associated NAICS code of 238170 - Siding Contractors. This award will be made on a Lowest Price basis. Award will be made to the responsible Quoter whose quotation conforms to the solicitation requirements. The Government will evaluate quotations based on price. System for Award Management (SAM) Registration: A prospective awardee shall be registered in the SAM database prior to award. Information on registration may be obtained via the Internet at https://sam.gov/content/entity-registration Proposal Submission: Quotes/Proposals (including any/all required documents) must be submitted via e-mail to john_ferrall@ios.doi.gov, no later than November 06, 2026, 5:00 pm EST. Please indicate the following in the subject line: Proposal Submission-140FF027Q0012. To maintain a complete record of inquiries and questions and to provide more detailed and faster responses, all questions shall be in writing via email (NO PHONE INQUIRIES). Questions may be emailed to john_ferrall@fws.gov. Inquiries received after October 30, 2026, 5:00 pm EDT, may not receive a response. If necessary, questions received will be answered through an Amendment to this Solicitation. Contracting Point of Contact: Drew Ferrall, Contract Specialist Department of the Interior US Fish and Wildlife Service john_ferrall@ios.doi.gov
49%
Combined Synopsis11/06/2026
46%
AwardedOpen
Publish questions and Answers received.
46%
Solicitation08/17/2026
Summary of Changes Please deliver bids to Dwayne Brauch, dwayne.brauch@va.gov Bid opening August 17, 2026 @ 10:00 am Microsoft Teams meeting Join: https://teams.microsoft.com/meet/226856731900460?p=sIkFuSwNDBiIivmfcb Meeting ID: 226 856 731 900 460 Passcode: Wb6sC7xr Need help? | System reference Dial in by phone +1 872-701-0185,,305028715# United States, Chicago Find a local number Phone conference ID: 305 028 715# For organizers: Meeting options | Reset dial-in PIN The following attachments are attached for this solicitation: Bid Questions Attachment F: Questions request form answered. Site Visit Agenda Site Visit Sign sheet Updated Wage Rate Determination for Stearns County VHA ICRA-1.4 (April 14 2026) B4.8.9
46%
Solicitation08/17/2026

Additional Details

Solicitation Number

JR1155376

Archive Date

Sep 15, 2025